Simplex 4007ES Fire Control Panels Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4007es-fire-control-panels-automatic-extinguishing-deluge-and-preaction-sprinkler-system-releasing-control-2673915408.pdf |
---|---|
Type | |
Size | 3.72 MB |
Downloads |
Text Preview
4007ES Fire Control Panels Extinguishing Deluge and Preaction Sprinkler System Releasing Control ULC Listed FM NYC Fire Approved control using the Simplex 4007ES Fire Alarm Control to provide Coverage for multiple areas of Automatic Extinguishing Release and Deluge and Preaction Sprinkler System Release including audible of events Control of compatible Listed Approved 24 VDC automatic control Releasing appliance circuits RACs by connecting Notification appliance NACs to Suppression Release Peripherals for actuator and control Additional actuator circuit control NACs are available using 4009 IDNet NAC Extenders with Suppression Release Peripherals Escalation of Events Temporal or 20 bpm march time pattern for first cross zone alarm 120 march time pattern to indicate releasing timer active On steady indicate releasing timer expired and actuator is activated Requires NACs dedicated to conventional horn control not SmartSync with strobes controlled on separate NACs IDNet NAC Extenders provide Up to eight NACs for notification requirements and input to release peripherals controlled via IDNet Suppression Release Peripheral SRP with Command Control Dual command control requires IDNet and an activated NAC to initiate NAC provides wiring supervision to the actuator including monitoring coil continuity and short circuit supervision to the coil supervision Release Peripheral control features An on board DC DC regulator compensates for voltage drops to the and ensures proper control circuit voltage over a wide range Provides a single RAC for control of actuators for up to 2 A using a 3 A input 1 A using a 2 A NAC input system components 4007ES Series control panel with Releasing Appliqu Dedicated NAC output from 4007ES or compatible NAC Extender Coil supervision module one per RAC Maintenance Switch one per RAC Abort Switch Listings reference UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service UL 2017 Emergency Alarm System Control Units CO detection FSZI ULC S559 Central Station Fire Alarm System Units DAYRC ULC S527 Control Units System Fire Alarm UOJZC Control Unit System Fire Alarm UOXXC Control Units Releasing Service SYZVC 1 Series Releasing Typical Block Diagram combined with Suppression Release Peripherals the 4007ES fire alarm control panel provides actuator supervision and control use in automatic extinguishing and deluge or preaction releasing Hazard area initiating and notification devices are controlled either conventional or addressable circuits per standard 4007ES The necessary releasing system logic is implemented within 4007ES control panel as required for the local application NYC Fire Dept COA 6191A Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the of Tyco Safety Products Westminster Release Control operation described in this document is also available with 4007ES Control Panels with software revision 3.03 or higher Refer to data S4007 0001 for model 4007ES control panel details including IDNet communications information Rev 7 4 2019 Extinguishing Deluge and Preaction Sprinkler System Releasing Control used connect to an addressable Supervised IAM model or similar addressable adapter module The Simplex switch and the IAM mount in a single gang box 2 1 2 depth Addressable Manual Releasing Stations are used to initiate of the releasing actuators with the appropriate time delay by the fire alarm control panel Notification Requirements Each hazard area typically requires audible and visible fire alarm notification and additional NACs for area releasing status notification Suppression is compatible with conventional panel mounted NACs as as for use with the 4009 IDNet NAC Extender Additional Suppression Release Peripheral Reference Refer to Instructions 579 385 Releasing Systems Reference additional information refer to Factory Mutual Research Corporation FMRC Approval Guide FM Approval standard Automatic for Preaction and Deluge Sprinkler Systems note that proper operation of releasing control systems requires the system design installation and maintenance be performed and in accordance with all applicable local and national codes equipment manufacturer instructions No liability for total system is assumed or implied Extinguishing Release Systems systems automatically activate electrically controlled actuators the release of a fire extinguishing agent such as dry chemical water foam CO2 or clean agent in response to fire detection device as determined by programming of the host fire alarm control Extinguishing Release System Panels are required to a minimum of 24 hours of standby power Initiating devices must Listed Approved for the application and may be wired either Class A B Control actuators must be electrically compatible with the control circuits and power supplies and are wired Class B to provide coil or Preaction Sprinkler Systems systems automatically activate water control actuators in to fire detection device inputs Sprinkler Systems employ open sprinkler heads and water flow when the fire detection system activates a common water control actuator They are used to deliver water through all of the system sprinkler heads This type of is applicable where the immediate application of large quantities water over large areas is the proper fire response Sprinkler Systems are similar to deluge systems except normally closed sprinkler heads are used and supervisory air is maintained in the pipe Operation requires both an activated head and an activated fire alarm initiating device with specific determined at the host fire alarm control panel System Requirements Releasing actuators are controlled from a Suppression Release 4090 9005 or 4090 9006 Connections are 2 wire B releasing circuits with only one 24 VDC actuator per Where applicable two 12 VDC actuators in series or one VDC actuator with manufacturer supplied resistor may be used to the actuator manufacturer installation documentation for details and requirements Coil Supervision Module 2081 9046 must be wired electrically the actuator and located in the actuator wiring junction box connected RAC provides continuity supervision of the actuator and wiring and provides short circuit supervision to the coil module Cross zoning or other alarm initiation logic per system is to be implemented by programming at the fire control panel UL Listed Automatic Extinguishing Releasing operation that battery standby must be a minimum of 24 hours 5 minutes of alarm and that listed actuators are used refer to Release Peripheral Wiring Reference FM Approved Automatic Extinguishing Release requires standby to be a minimum of 24 hours with 5 minutes of Actuators must be electrically compatible FM Approved Deluge and Preaction Sprinkler operation that initiating device circuits be Class A and wired to Listed devices standby power capacity must be a minimum of hours with 10 minutes of alarm and that compatible Automatic Control Valves must be used Refer to actuator list in the section Maintenance Switches one per RAC are required per NFPA 72 National Fire Alarm and Signaling Code to allow the system to be or serviced without actuating the fire suppression systems use may not be allowed in some jurisdictions always confirm requirements When used Simplex Maintenance Switches are to ensure that operation initiates a supervisory condition Abort Switches are available when abort operation is required 2 Rev 7 4 2019 Extinguishing Deluge and Preaction Sprinkler System Releasing Control Selection Supervision Module Series Switches Refer to data sheet S2080 0010 for Abort and Maintenance switch details mount mount Switch 1 4007ES Releasing Control System Modules one per RAC mounts in the releasing actuator wiring junction box see section for details per RAC flush or surface mount indicator lamp models require separate 24 wiring requ