Simplex 4007ES Fire Control Panels; Fire Detection and Control with Addressable Initiation and Addressable Notification [For INTERNATIONAL USE ONLY];
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4007es-fire-control-panels-fire-detection-and-control-with-addressable-initiation-and-addressable-notification-for-international-use-only-6740159832.pdf |
---|---|
Type | |
Size | 3.34 MB |
Downloads |
Text Preview
ULC CSFM Listed NYC Fire Dept Approved Flexible standard combination of addressable and addressable notification 109 mm Diagonal color touchscreen display Convenient and intuitive user interface provides detailed status and individual point information Supports dual language selection including unicode languages A custom background display appears when operation is see page 7 for details a 3 A IDNAC SLC signaling line circuit power supply that provides enhanced power to addressable notification appliances A constant 29 VDC source voltage is maintained during even during battery operation allowing strobes to at higher voltage with lower current and ensuring a current draw and voltage drop margin under both power and secondary battery standby Efficiencies include lower strobe currents wiring distances to 2 to 3 times farther than with conventional support for more appliances per IDNAC SLC smaller gauge wiring This provides installation and savings with high assurance that appliances operate as normal during worst case alarm conditions SLCs are compatible with both TrueAlert ES and addressable notification appliances and remote IDNAC Repeaters to extend power and wiring distance farther and provide for up to 127 addressable appliances Power supply provides battery backup charging of up to Ah up to 18 Ah for cabinet mounted batteries and up 33 Ah batteries for mounting in close nippled remote cabinet isolated IDNet addressable initiating SLC Provides built in short circuit isolation for monitoring control of TrueAlarm analog sensors and IDNet monitoring and control devices for use either shielded or unshielded twisted or untwisted pair wiring outputs are Class A or Class B Standard panel SLC provides up to 100 addressable optional additional loop expansion modules an additional isolated loop with short circuit for the IDNet channel each loop expansion also provides an additional 75 addressable points the IDNet channel capacity for a total of up to 250 points Feature Summary Current and previous panel configuration are both in on board memory to allow easy selection of revision An internal Ethernet service port is available for service connections to perform configuration updates and uploads report downloads and system updates USB interface allows a memory stick thumb drive store job revisions update revised jobs and panel and save detailed system reports from the panel 4007ES Fire Control Panels Fire Detection and Control with Addressable and Addressable Notification Panel Front View modules and connections include Fire Alarm Network Interface for Peer to Peer fire alarm communications supports either Class B or Class operation Point or Event DACT assembly that is compatible with IP Up to two additional IDNet addressable device output connections with 75 additional point capacity each Front mounted 48 LED annunciator with custom label Dual Class A IDNAC Isolator DCAI Remote LED annunciator support via RUI remote unit communications port for use with unshielded pair wiring UTP Eight Point Zone Relay Modules individually selectable IDC or relay rated 2 A 30 VDC resistive Alarm relays and auxiliary relays Dual RS 232 ports for printer PC annunciator or third interface TrueInsight Remote Gateway City connections with or without disconnect switch 4003EC Voice Control Panels 4009 Series IDNAC Repeaters Battery brackets for seismic area protection see page 2 Mechanical Compact red or platinum cabinet for convenient surface or mounting rated NEMA 1 and IP30 Listings reference UL 864 Control Units System UOJZ Control Unit System Fire Alarm UOXX Control Releasing Device Service SYZV UL 2017 Emergency Alarm System Control Units CO FSZI ULC S559 Central Station Fire Alarm System Units ULC S527 Control Units System Fire Alarm UOJZC Unit Accessories System Fire Alarm UOXXC Units Releasing Device Service SYZVC This product has been approved by the California State Fire Marshal pursuant to Section 13144.1 of the California Health and Safety Code CSFM Listing 7165 0026 0378 for allowable values and or conditions material presented in this document NYC Fire Dept COA 6191A listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Co are the property of Tyco Fire Protection Products 1 2017 Introduction 4007ES Series Fire Detection and Control Panels extensive installation operator and service features point and module capacities suitable for a wide range of applications Panels can be configured for stand or networked fire control operation The convenient intuitive color touchscreen provides easy access for system response actions and for detailed system or configuration updates with password control to user access addressable initiation communications and IDNAC notification communications are standard Refer to data sheet S4007 0001 for 4007ES panels conventional notification Interface Convenient Status Information With the locking door the glass window allows viewing of the display LEDs The user interface is a 4.3 diagonal color LCD with separate status LEDs as shown indicators describe the general category of activity displayed with the LCD providing more detail For the user unlocking the door provides access to the functions and allows further inquiry by scrolling the for additional detail Operator Interface and Software Features Convenient and detailed operator information is easily using a logical menu driven touchscreen with password access control Multiple automatic and manual diagnostics for reduction Operator Interface Features Continued Alarm and Trouble History Logs up to 1000 entries for 2000 total events are available for viewing from display or for printing to a connected printer or to a service computer Module level ground fault searching assists installation service by locating and isolating modules with wiring WALKTEST silent or audible system test performs an self resetting test cycle and supports up to 8 groups Install Mode allows grouping of multiple troubles for modules and devices into a single trouble typical with future phased expansion with equipment and devices grouped into a single operators can more clearly identify events the commissioned and occupied areas Description Locking door with polycarbonate window Latching front panel assembly swings forward for internal access Smooth box surfaces are provided for locally cutting entrance holes exactly where required Modules are power limited except as noted such as modules Battery compartment bottom accepts two batteries to 18 Ah to be mounted within the cabinet without with module space charger capacity is up 33 Ah for batteries greater than 18 Ah refer to 7 for external battery cabinet details Cabinet assembly design has been seismic tested and certified to IBC and CBC standards as well as to 7 categories A through F requires battery as detailed on data sheet S2081 0019 Touchscreen Display with LED Status Indicators approximately full size LED