Simplex 4008-9101, 4008-9102, 4008-9121, 4008-9122, 4008-9801, 4008-9802 4008 Addressable Fire Alarm Control Panel for up to 200 IDNet Addressable Devices and TrueAlarm Addressable Smoke Detection

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Addressable Fire Alarm Control Panels 4008 Fire Alarm Control Panel for IDNet Addressable and TrueAlarm Addressable Smoke Detection panel operator convenience features Wide viewing angle 2 x 20 40 character alphanumeric and dedicated LEDs provide convenient panel information Operation is programmable using a multi function and the panel LCD or via service computer PC RS 232 service port provides upload download PC for panel configuration and event history logs Software updates are via PC download Convenient library of standard custom label terms Standard on board DACT provides Contact ID 3 1 4 2 and SIA formats WALKTEST silent or audible system test Voltage and current for both the battery charger and the can be displayed at the front panel LCD Devices Using IDNet communications up to 200 addressable detection points or addressable device points available see page 3 for details Standard Notification Appliance Circuits NACs Class A or Class B outputs with solid state overcurrent per NAC each rated for 2 A Selectable for Simplex SmartSync two wire control or synchronized strobe control Power Supply Provides 3 A maximum nominal 24 DC Automatic input power selection operates with 120 VAC 240 VAC 50 or 60 Hz On board temperature compensated battery charger for to 12.7 Ah batteries in cabinet UL and ULC and up 25 Ah batteries in separate cabinet UL only standard features Programmable Active Status Reminder Two auxiliary relays NACs Relay outputs and communications circuits power limited AC input battery circuits and City Module outputs are non power limited Available with beige or red cabinet UL listed to Standard 864 option modules Door mounted 24 LED annunciator standard on ULC 3 A Expansion Power Supply with two on board 2 A that operate the same as standard NACs City Interface Module and Auxiliary Relay Module Remote LCD and LED Switch Annunciators Beige Standard Control Panel i r e A l a r m A n n u n c i a t o r AND C POWER AND C POWER Beige Control Panel with 24 LED Annunciator for ULC applications areas requiring up to 200 addressable input devices and to 4 NACs the Simplex 4008 Series fire alarm control provide flexible initiating circuit monitoring programmable control capability and LCD circuit specific 20 character custom labels See page 2 for additional ULC and MEA information This product has been approved by California State Fire Marshal CSFM pursuant to Section 13144.1 of the California and Safety Code See CSFM Listing 7165 0026 318 for allowable values and or concerning material presented in this document It is subject to re examination and possible cancellation Additional listings may be applicable contact your local product supplier for the latest status Listings and approvals under Simplex Time Co are the property of Tyco Fire Protection Products 8 2012 Standard Feature Details operation is provided by an IDNet line circuit SLC capable of communicating to up 200 addressable devices points Addressable devices TrueAlarm smoke detection heat detection and detection supervised addressable modules for single multiple contact monitoring manual stations isolation and a remote signal module see list on page 4 note that this panel provides a limited TrueAlarm feature set For larger applications that require the complement of TrueAlarm features contact your local product supplier 2 A On Board NACs provide conventional reverse operation selectable as Class A or Class B with control and overcurrent protection Operation is for synchronized strobe or SmartSync two wire operation Horn control can be at the panel for Temporal pattern coding Steady Slow March Time of 20 beats per minute BPM or March Time of 120 BPM Note When selected for horn strobe control March Time produces BPM 24 VDC Auxiliary output provides up to 500 mA system use Auxiliary output current is counted for power supply capacity Auxiliary Relay Outputs Two relay outputs available selectable as normally open or normally rated 2 A 30 VDC per below Relay 1 is normally assigned to General Alarm but is programmable see page 7 Relay 2 Trouble is energized when Normal and is with a Trouble condition Product Selection Panel Description fire alarm control panel Beige Red Beige Fire alarm control panel with 24 LED Red Modules on front door Standard Feature Details Continued Dual Line DACT Operation can be selected Contact ID SIA 3 1 4 2 and BFSK formats includes Alarm Supervisory Trouble and AC Operation includes automatic 24 hour test and power fail report delay Supply and Battery Charger DC power output 3 A 24 VDC for panel use The temperature battery charger sealed lead acid batteries is rated for up to 25 Ah batteries per UL 864 and up 12.7 Ah per ULC S527 Up to 12.7 Ah batteries fit in cabinet larger batteries require an external cabinet electronics can measure and display voltage and for the power supply batteries and the battery standard and expansion power supply Depleted trouble is monitored and annunciated and depleted cutout can be selected Active battery status supervises charger operation Feature Details Power Supply Provides 3 A total VDC two additional 2 A NACs and an additional power output of 500 mA Output operation is the as on the standard power supply Relay Module Provides three relays one for Alarm Supervisory and Trouble conditions is jumper selectable as N O or N C Contacts are 2 A 30 VDC Location is the same as for the City Modules Circuit Modules These modules are available with without on board disconnect switches depending on requirements either type can be disconnected the front panel under password control are for Remote Station reverse polarity or Master local energy Reporting includes Supervisory and Trouble FM Feature Summary with 200 addressable points Class B Class A NACs 3 A power with battery charger on board for input voltage of VAC 50 60 Hz autoselect Expansion Power Supply 3 A with 2 NACs 120 240 VAC 50 60 Hz Expansion Relay Module 3 relays selectable as either N O or N C City Circuit Modules with disconnect switch City Circuit Modules without disconnect switch These City Circuit modules are also used on the 4006 Series control panels one if required one if required Beige semi flush trim kit 1 7 37 mm wide includes four corners and trim pieces for top bottom and sides Red semi flush trim kit 1 7 37 mm wide includes four corners and trim pieces for top bottom and sides Beige External Battery Cabinet for up to 25 Ah batteries mounts close nippled to control panel cabinet 12 Volt select one battery model per system standby requirements order quantity of two 16 W x 13 H x 5 D 413 mm x 343 mm x 146 mm Ah 2081 9288 12.7 Ah Ah cabinet mount 18 Ah Requires 4009 9801 External Battery 25 Ah UL listed only 8 2012 TrueAlarm Smoke Detection Addressable Detection IDNet addressable compatibi

Related Files