Simplex 4008 Addressable Device Compatiblity Chart

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4008-addressable-device-compatiblity-chart-0841623759.pdf
Type PDF
Size 638.81 KB
Downloads

Text Preview

MAPNET II and IDNet Addressable Devices Communications Compatibility Chart Compatible with MAPNET II 4010 IDNet 4100U and 4008 IDNet Communications B IDC ZAM Base with connections for remote or relay and supervised remote relay A IDC ZAM Sensor Base Sensor Housing without relay Base Sensor Housing with relay Station Standard Sensor Housing without relay Station Breakglass Sensor Housing with relay Station Push Base with connections for remote LED or unsupervised relay ULC FM MEA with Special Considerations IAMs 4090 9051 is and w o LED II provides Class B monitoring of N O contacts from 4008 4010 or 4100U also provides sense Addressable Controller IDNet 4100 and 4100U control using RUI Address Base Address Base use with only II 4010 IDNet and 4008 IDNet two consecutive does not provide TrueSense operation see for 4100U applications of 4098 9754 ULC FM MEA Multi Sensor one address for heat and TrueSense operation only 4100U IDNet only use with standard sensor bases only one address Releasing Station Push with MAPNET II or IDNet Releasing panels only mA AMZ revision 2.01 firmware II or 4100U IDNet Operation MAPNET II one unit load IDNet requires two unit loads MEA not applicable for this product LaserCOMPACT II or 4100U IDNet Operation Compatible with 4010 IDNet or 4100U IDNet Communications Only except as noted IDNet NAC Extender 4009 A 4100U rev 11 software IAM Base for use with 4008 B A Fiber Optic Transmitter MEA approved Release Peripheral SRP enclosure uses 2975 9227 ULC not applicable Repeater not MEA approved SRP with Enclosure Compatible with 4100U IDNet Communications Only except as noted Communications Isolator compatible with 4008 IDNet Relay IAM with T Sense Input Power Isolator Relay IAM with unsupervised input Monitor IAM two unit loads Module 4 T Sense inputs 2 relays Compatible with MAPNET II Communications Only 9154 Monitor ZAM Style D IDC 9162 Signal ZAM Style Y NAC 9156 Monitor ZAM Style B IDC 9164 Control Relay ZAM DPDT Contacts 9158 Detector ZAM IDC I O Module 9160 Signal ZAM Style Z NAC Compatible with 4010 IDNet Communications or 4100U with 4100 3106 IDNet Expansion Module Sensor uses 4098 9788 multi purpose base Compatible with 4008 Panel IDNet Communications Only Signal IAM Requires 4010 Revision 3.01 software or higher or 4100U Revision 11.05 software or higher Requires 4100U Revision 11.0 software or higher IDNet Isolators are not compatible with the 4100 3103 Quad Panel Mount Isolator if required use 4100 3107 IDNet Module Note Listings are as of document revision date refer to individual product data sheets for more information 4 2005 ULC ULC ULC FM MEA in ULC FM MEA ULC FM MEA ULC FM MEA ULC II Communications Communications does it mean is an acronym for Multi Application Peripheral MAPNET II was introduced as an improved of MAPNET I in 1991 The improvements electrical design changes that impacted both the and receive circuits and provided better electrical immunity and overall improved performance is it used includes system models 4020 4100 4120 and and with 2120 Systems using the CDT Device Transponder All MAPNET II control modules communicate only with II compatible addressable devices However addressable devices can automatically adapt to with either MAPNET II or IDNet protocols does it do II is an addressable communications protocol provides power and half duplex communications over single pair of wires for up to 127 addressable devices communications are bi directional but occur one direction at a time Information can include status trouble alarm abnormal etc and commands as turn on or off a relay reset a ZAM or activate a base Additionally TrueAlarm analog sensor is communicated via MAPNET II or IDNet communications does it work control panel sends out polling commands for status or individual device commands This occurs imposing voltage variations on a steady DC level the polling stops the DC level is held high and responding device answers per its unique address by a resistor onto the DC circuit causing data to be at the panel The steady DC level provides power the MAPNET II communications receiver circuit and some low power devices such as basic smoke heat and IAMs can power the entire device meaning a single wire pair is required MAPNET II and IDNet addressable communications designs are protected by U S Patent 4,796,025 Other applicable patents are detailed on individual product data sheets note that listings and approvals shown on page 1 that are under Simplex Time Co are the property of Tyco Safety Products Westminster does it mean is an acronym for Individual Device Network The design is the next generation of addressable device improving upon the basic MAPNET II protocol is it used communications are provided by the Simplex 4100U and 4008 Fire Alarm Control Panels In to MAPNET II IDNet addressable devices communications also control unique devices such the IDNet Isolator base the 4009 IDNet NAC and the Security IAM Newer versions of software revision 11 and higher also with multi point relays and the multi However each of these three panels provides different IDNet device compatibility does it do operation is similar to MAPNET II but there are differences The IDNet protocol and hardware support up to 250 addressable devices on single wire pair and can support additional device types different operations The 4008 Fire Alarm Control provides up to 200 addressable device support does it work operation is similar to that of MAPNET II but with expanded capability that requires a different control to decode the additional device types and operations with IDNet communications is the difference between 4010 IDNet and IDNet basic communications protocol of IDNet is similar as RS 232 or RS 485 is similar However even the IDNet communications protocol is similar not control panels can recognize all addressable devices a higher end panel 4100U IDNet has been designed higher end performance For compatibility reasons is a distinction between 4010 or 4100U IDNet is the difference between 4010 IDNet and IDNet 4008 Addressable panel provides a unique set of It is for smaller applications and only two sensitivity levels are supported However it capable of controlling the 4090 9116 IDNet Isolator and it is compatible with the 4090 9007 IDNet Signal IAM is IDNet 4100U optional module that provides isolated IDNet for improved noise immunity This IDNet circuits to use existing unshielded and wiring in conduit with other fire alarm circuits includes a built in quad isolator for superior and

Related Files