Simplex 4009-9601, 4009-9601BA, 4009-9602, 4009-9602BA, 4009-9801, 4009-9814 TrueAlert Addressable Notification; 4009 IDNAC Repeater; Power and Distance Extender; with IDNAC Notification (B) (G)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Addressable Notification IDNAC Repeater and Distance Extender IDNAC Repeaters provide enhanced power to TrueAlert TrueAlert ES addressable appliances controlled by IDNAC SLCs Output voltage is maintained by efficient switching at 29 VRMS during both AC and battery conditions allowing strobes to operate at lower With lower current strobes and regulated output wiring distance can be extended 2 to 3 times of conventional notification appliance loading can increased or smaller wire gauge can be used all in installation savings with high assurance appliances that operate during normal system will operate during worst case alarm conditions IDNAC Repeaters receives an IDNAC SLC and provide a repeated 3 A SLC output to SLC distance and power Appliance control remains with the host IDNAC panel and Repeater operation is essentially Repeater status is communicated to the panel for system diagnostics and also indicated SLC connection can be Class B or Class A Repeater output can be a Class A loop or a Class B with internal connections for up to four 4 output branches Class A output requires Class A Adapter Operation requires one IDNAC SLC address can be connected as one in series or up five 5 in parallel AC power input is 120 VAC or 220 240 VAC Hz auto select An on board battery charger is provided with low battery disconnect selectable per Repeater for ULC listed applications Operation is compatible with TrueAlert ES and addressable notification appliances and Available with platinum or red cabinet Listed to UL 864 and ULC S527 wiring options are available Wiring options include Class B multiple branch up to 4 Class A loop extension and Class A riser to B branches or a Class A loop output When the Repeater is part of a Class A loop from the SLC source panel up to twice the distance for loop is available Class A loop repeating requires Class A Adapter A Adapter 4009 9816 Required when extending a Class A loop or to provide a A local loop SLC output Operation provides short circuit isolation between input output terminals for improved IDNAC SLC IDNAC SLC and BATTERY A C PO WER SERVICING EN C A LA BATTERIE AVANT L IDNAC SLC with EPS Supply IDNAC Repeater Extends Distance Current of IDNAC SLC Continued battery Charger Power supply charges up to 12.7 Ah batteries for in mounting and up to 25 Ah batteries with model external battery cabinet auxiliary output A 200 mA 29 VDC constant auxiliary output is operation is maintained during battery backup This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this This product was not FM approved as of document revision date Additional may be applicable contact your local Simplex product supplier for the latest status and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 5 2013 Introduction Repeating IDNAC SLCs 4100ES fire alarm control with an EPS or EPS enhanced power supply individual address and control of TrueAlert and ES addressable notification appliances using SLCs When an IDNAC SLC reaches the current or the distance limit of the source IDNAC SLC use 4009 IDNAC Repeaters extends the IDNAC SLC with additional 3 A of SLC current IDNAC SLCs a constant 29 VRMS source voltage maintained even during battery standby allowing to operate at higher voltage with lower current and a consistent current draw and voltage drop under both primary power and secondary battery Efficiencies include wiring distances up to 2 to 3 farther than with conventional notification or for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm Description wiring configurations are available to provide variety of system solutions Class B branch extension A loop extension and Class A riser to Class B extension or Class A loop output Description Continued B branch input wiring allows T tapped to up to five 5 parallel connected 4009 Repeaters Each Repeater has on board output connections for up to four 4 output branch and additional branch circuits can be externally as required Refer to diagram on page 3 for details A loop extensions use a single 4009 IDNAC to extend the current and distance of a single A loop allowing the loop distance to be doubled Repeater communicates and repeats bi directionally Class A loop operation to be maintained in the of an open circuit This wiring connection requires of the 4009 9816 Class A adapter Refer to diagram page 4 for additional details A Riser to Class B Branches or Class A For applications requiring a combination of types a Class A riser can drive up to five 5 4009 Repeaters with each Repeater capable of driving single or multiple Class B branch output s or a A loop output In this wiring application the does not repeat in the Class A riser loop it is as an appliance with Class A in out wiring To a Class A loop output the Repeater must be with a 4009 9816 Class A Adapter Refer to on page 5 for additional details Product Selection Color Description Platinum Red Add suffix BA to select 4009 IDNAC Repeaters assembled in the USA Accessories installed on site select per system requirements IDNAC Repeater with cabinet provides a single 3 A IDNAC SLC output 200 mA auxiliary output and battery charger 120 240 VAC 50 60 Hz input auto select Class A Adapter Module mounts on repeater controller board required for Class A output Platinum semi flush box trim Red semi flush box trim Accessories select per system requirements 7 37 mm wide four corners and trim pieces for top bottom and sides will to be cut to fit 4009 IDNAC Repeater cabinet Remote TrueAlert Communications Isolator Refer to data sheet S4905 0001 for details External Battery Cabinet for 25 Ah batteries 16 W x 13 H x 5 D 413 mm x 343 mm x 146 mm refer to sheet S2081 0006 for details Selection select battery size per system requirements two batteries are required for 24 VDC operation 6.2 Ah Battery 12 VDC 10 Ah Battery 12 VDC 12.7 Ah Battery 12 VDC 18 Ah Battery 12 VDC 25 Ah Battery 12 VDC 4009 9801 External Battery Cabinet 5 2013 Wiring Reference Class B Input with Class B Branch Circuit Outputs IDNAC Repeaters B Branch Extensions maximum SLC output SLC input B IDNAC SLC B IDNAC SLC with EPS Supply B wiring can T tapped Notes Up to five 5 4009 IDNAC Repeaters can be in parallel as shown on this diagram IDNAC SLC communications can be repeated once between the source and the appliance The 4009 IDNAC Repeater extends distance current of the input IDNAC SLC it one address and consumes four 4 loads 4009 IDNAC Repeater has duplicate output rated for two wires each allowing up to 4 Class B branch circuit T taps to be made the cabinet additional T taps may be made in wiring junction cabinets or boxes B IDNAC SLC B IDNAC SLC B IDNAC SLC B IDNAC SLC Circuits 5 2013 Wiring Reference Class A Loop Extension A IDNAC SLC Loop with 4009 IDNAC Repeater Extending Loop Range and Power IDNAC Repeater Requires optional 4009 981

Related Files