Simplex 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4009-idnet-nac-extender-for-control-with-idnet-communications-or-conventional-nacs-4972085163.pdf |
---|---|
Type | |
Size | 1.50 MB |
Downloads |
Text Preview
UL ULC CSFM Listed MEA NYC Fire Alarm Controls IDNet NAC Extender for Control with IDNet Communications or Conventional NACs information For additional operation detail and information refer to Installation Instructions 574 181 and wiring diagram 842 068 4100U requires revision 11 software or higher for compatibility requires revision 2 software or higher for compatibility additional notification appliance circuit NAC capacity flexible operation modes and power limited design Class B NACs are standard Rated 2 A each for conventional reverse polarity 24 VDC notification and providing multiple operation modes Can be selected to provide synchronization for Simplex visible strobe flashes Capable of controlling TrueAlert non addressable notification operating with SmartSync two wire control mode control options IDNet addressable communications from a 4007ES 4010 4010ES or 4100ES Fire Alarm Control Panel See note Or from one or two conventional 24 VDC NACs with multiple output options communications control benefits Provides status monitoring and individual NAC control using a single per 4009 IDNet NAC Extender Supports IDNet Level earth fault location operation is available with either input choice 8 A power supply battery charger Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in cabinet Provides status monitoring of battery input power and earth faults Rated 8 A for Application appliances including 4901 4903 and 4906 Series horns strobes horn strobes and speaker Rated 6 A for 24 DC appliance power 4009 IDNet NAC Extender modules IDNet Communications Repeater provides Class B or Class A output IDNet Communications Fiber Optic Receiver Repeater available as B or Class X Four additional Class B NACs rated 1.5 A for Special Application 1 A for Regulated 24 DC appliance power Class A Two Circuit Adapter Module Listed to Standard 864 Accessories communication fiber optic transmitters For applications requiring the data integrity available with fiber optic Available as Class B or Class X Mounts in standard six gang electrical box battery cabinet for 18 Ah batteries compliance Complying with the notification requirements of Americans with Disabilities Act may require more notification power than is available within the fire alarm control panel additional power is required a 4009 IDNet NAC Extender can up to 8 A of NAC power with up to eight supervised reverse NACs flexibility The 4009 IDNet NAC Extender can be mounted to a compatible dedicated host panel or can be located remotely convenient power distribution Multiple operation modes and connection options further increase location flexibility 1 4009 IDNet NAC Extender reference drawing listed model is 4009 9202CA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this document Accepted for use City of New York Department of Buildings MEA35 93E Additional listings be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection Products Rev 15 9 2019 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs and operation information addressable communications compatible Up to 10 4009 IDNet NAC Extenders can be controlled for each 4007ES 4010ES 4100U or IDNet communications channel up to 5 can be controlled on the 4010 IDNet communications channel Each output NAC can be individually for general alarm or selective area notification requiring only one point address for each Extender Individual Extender NACs can also be controlled from the host panel IDNet controlled extenders will inform the host panel of troubles using IDNet communications 4007ES 4100ES and 4100U control panels control using multi point rules refer to data sheet S4090 0011 for details IDNet repeaters IDNet communications can be repeated with the optional IDNet Repeater Module or with the optional Fiber Optic Module Up to 100 of the IDNet channel points can be repeated once refer to Typical IDNet connection example and 4009 IDNet NAC specifications for details Repeated IDNet communications also support the device level earth fault location utility of the host panel control applications For applications where an existing or new conventional NAC needs additional power the 4009 IDNet NAC can be controlled directly from the NAC Either one or two NACs from either the same or from different host fire alarm control panels can connected to control the 4009 IDNet NAC Extender output NACs Multiple control selections provide flexible operation See Hardwire Control Information for more detail Alarms from the host panel will activate the four 4009 IDNet NAC Extender NACs or optionally 8 NACs to the alarm 4009 IDNet Extender monitors itself and each of its output NACs for trouble conditions including earth faults Extenders wired to conventional will indicate a trouble by opening the path to the NAC end of line resistor but retaining the ability to respond to alarms Individual troubles also annunciated by LEDs located on the 4009 IDNet NAC Extender main circuit board Refer to Service diagnostic features for more diagnostic selection 1 Standard models ULC listed model 4009 9201 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F requires battery brackets detailed on data sheet S2081 0019 IDNet NAC Extender with 4 Class B NACs 8 A power supply VAC input VAC input VAC input Optic Receiver Appliqu for door Trim Kit Ah Battery 12 VDC Ah Battery 12 VDC Ah Battery 12 VDC Ah Battery 12 VDC 2 Optional modules for on site installation four point NAC module rated 1.5 A Special Application 1 A for Regulated 24 DC appliance power Class B Class A adapter for two NAC outputs Repeater output is Class A or Class B maximum B A IDNet Class X fiber trim trim as required 4 maximum either an IDNet Repeater or a Fiber Optic as required one transmitter can connect one receiver if required 7 16 in wide 78 mm use if required for semi installations 3 Battery selection select battery size using system requirements 4 External accessories select using system requirements B operation Fiber Optic X operation battery cabinet for up to 18 Ah batteries beige resistor harnesses see data sheet S4081 0003 for details batteries are required 24 VDC operation external battery cabinet two batteries are 24 VDC operation in six gang electrical box refer to IDNet fiber optic transmitter information for mounting details Class B Fiber Transmitter Rev C or higher NOT COMPATIBLE with Class B Fiber Receiver Rev J in W x 13 1 2 in H x 5 3 4 in D 413 mm x mm x 146 mm series 2 Rev 15 9 2019 IDNet connection example IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Up to 10 4009 IDNet NAC Extenders may be connected using 4007ES 4010ES 4100U or 4100ES IDNet channel up to 5 on the 4010 IDNet IDNet communications can be repeated only once can pass through only one series connected repeater or one fiber optic receiver 2 IDNet connection example 3 Rev 15 9 2019 fiber optic system connections IDNet NAC Extender for Control with IDNet Communications or Conventional NACs 3 fiber optic system connections Up to 10 4009 IDNet NAC Extenders may be connected per 4007ES 4100ES or 4010ES Up to 5 4009 IDNet NAC Extenders may be connected the 4010 IDNet channel IDNet communications can be repeated only once can pass through only one series connected repeater or one fiber receiver Fiber optic transmitters connect to only one receive