Simplex 4010-9803 Relay Module Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4010-9803-relay-module-installation-instructions-3579108624.pdf
Type PDF
Size 672.35 KB
Downloads

Text Preview

Cautions and Warnings Relay Module Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of carton for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area may cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install the 4010 9803 Relay Module 566 058 a 4010 Fire Alarm Control Panel FACP Only one of these modules can installed in a 4010 FACP A 4010 FACP supports either a 4010 9803 Relay or 4010 9809 or 9829 City Circuit card to the 842 058 Field Wiring Diagram for additional wiring information This Publication publication covers the following topics Page Module Parts 1 742 310 Service Parts List Number Module Harness Bracket Screws Screw with Lock Washer 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice B Relay Module the Relay Module 4010 9803 Relay Module connects to the SFI O board of a 4010 FACP with ribbon harness 733 952 The relay module provides connections to different through three dry relay contacts providing Alarm Supervisory and reporting If a CPU failure occurs the relay module trouble output See Figure 1 below for connector locations applications requiring relay contact outputs for Alarm Supervisory and the 4010 9803 Relay Module converts the open collector City DACT into individual relay contacts that can be jumper selectable as either Open NO or Normally Closed NC Troubles on the relay card report as a City Circuit Trouble relay output is rated 2A 32 VDC maximum and is for controlling power a power limited fire alarm power supply listed for the application The relay activates on an Alarm condition until reset The Supervisory relay on a Supervisory condition until clear The Trouble relay activates on a condition until clear Each relay has an LED to indicate its ON OFF Bracket The relay module has dry relays There are no markings on board or terminal block P1 P2 and P3 are shown in the Closed position Pin 1 P1 P2 and P3 is the TOP pin the relay module 1 ALARM 1 4010 9803 Relay Module the information in Table 2 to set the jumper positions for relays K1 K2 K3 to utilize Normally Open NO Normally Closed NC contact positions 2 Jumper Positions for NO and NC Relay Contacts Open Closed K1 Alarm K2 Supervisory K3 Trouble to P1 3 to P2 3 to P3 3 to P1 2 to P2 2 to P3 2 relay module circled in Figure 2 installs in a hardware slot located to the of the 4010 SFI O board Use Steps 1 through 9 to install and program the module Disconnect battery power from the 4010 FACP At the breaker disconnect AC power from the 4010 FACP Ensure the jumpers on the module are set to the proper position before With TB1 of the relay module in the top position slip the top hole of the module bracket over the flange located on the 4010 chassis Use the supplied slotted TORX screw 441 002 and lock washer to secure bottom end of the module bracket to the chassis Terminate all wiring to the appropriate connectors Using the ribbon harness connect one end from P4 of the relay module to P2 of 4010 SFI O Board refer to Figure 2 for the location of P2 The ribbon harness is keyed to the LEFT to ensure proper orientation From the breaker apply AC power to the FACP Apply battery power to the FACP 4010 9820 Module 4010 9825 Extender Terminal Block Power 565 792 Power 565 793 Class A Module 565 789 Class A Module 565 789 Pot for LCD Adjustment PTCs MUST NOT TOUCH EACH OTHER OR ANY OTHER METAL SURFACE 2 4010 9803 Relay Module Location on next page Continued installing the 4010 9803 Relay Module follow Steps 10 through 16 to it for the 4010 FACP Log in to the 4010 FACP at Level 4 Simplex Service Mode Press the MENU button and then the NEXT or PREVIOUS button Programming is displayed Press ENTER Wait for the trouble piezo to sound and press ENTER The trouble LED continuously blinks while in the mode Press the NEXT or PREVIOUS button until System Options is Press the NEXT or PREVIOUS button until Enable City Circuit is Press ENTER Press ENTER Press the NEXT or PREVIOUS button until NEW ON is displayed ENTER to update the option Press ENTER to confirm Save your CFIG with the new settings now in place the 4010 9803 Relay Module is not programmed the system it will work as designed but WILL indicate a card trouble B

Related Files