Simplex 4010-9806 NAC Class A Adapter ™ Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4010-9806-nac-class-a-adapter-installation-instructions-6914805372.pdf |
---|---|
Type | |
Size | 693.80 KB |
Downloads |
Text Preview
Cautions and Warnings NAC Class A Adapter Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area is likely to cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install the 4010 9806 Class A Adapter Module a 4010 Fire Alarm Control Panel FACP One of these modules is needed every two NAC circuits for Class A operation on the 4010 to the 4010 Fire Alarm Installing Operating and Programming 574 052 for configuration information Refer to the 842 058 Field Diagram for additional wiring information Page Class A Adapter Module Installation this Publication publication discusses the following topics 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice B Class A Adapter Module four NACs found on the 4010 SFI O board are Class B Style Y To Class A Style Z you must install an adapter module that mounts to the board Each 4010 9806 Class A adapter module supports up to two 1 shows the location of the P1 connector and the Class A terminal block 1 or 3 NAC 2 or 4 A Terminal Block Interface Header 1 4010 9806 Class A Module A Wiring Class A wiring is terminated at TB1 on the module Maximum current for circuit is 2A Use the information in Figure 2 to terminate all Class A Refer to the 842 058 Field Wiring Diagram for complete wiring appliances current and line distance information 1 2W EOL a 733 894 10KW harness from to terminals of Class A NAC in use on the Class A Remove any installed resistors the associated NACs on the SFIO 565 737 or 565 738 All wiring to be 18AWG minimum or to code All wiring is supervised 2 Class A Wiring Installation the Class A Adapter a Class A module piggy backed onto the 4010 SFI O Use the following and Figure 3 to mount the module on a 4010 Disconnect battery and then AC power from the FACP Terminate all wiring to their appropriate connectors Press two Snap Posts Part No 202 067 into the appropriate holes on the SFI O see Figure 3 the 8 pin header Part No 532 624 into the 8 pin socket on the 4010 Line up the back 8 pin connector of the Class A module with the 8 pin installed on the 4010 SFI O and line up the two mounting holes and the Class A module into place can now reconnect AC and Battery Power A Snap Post Header Socket Class A Module 565 789 Class A Module 565 789 Pot for LCD Adjustment Module 4010 9820 Module 4010 9825 Extender Terminal Block PTCs MUST NOT TOUCH EACH OTHER OR ANY OTHER METAL SURFACE 3 Class A Module Installation Power 565 792 Power 565 793 B