Simplex 4010-9812 RS232 Service Modem Card Rev B

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4010-9812-rs232-service-modem-card-rev-b-1543268097.pdf
Type PDF
Size 712.27 KB
Downloads

Text Preview

Cautions and Warnings Dual RS232 and RS232 Service Modem Installation Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area is likely to cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install the 4010 9811 Dual RS232 or 4010 9812 Modem Optional Cards into a 4010 Fire Alarm Control Panel Only one of these option cards is allowed per system Refer to the Fire Alarm Installation Instructions 574 052 for configuration Refer to the 4010 Fire Alarm Front Panel Programming Part No 574 054 for programming information Refer to the 842 Field Wiring Diagram for additional wiring information Page and IC Requirements Dual RS232 Card RS232 Service Modem Card Installation this Publication publication discusses the following topics 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice Manuals Online B and IC Requirements Requirements The Federal Communications Commission FCC has established Rules permit this device to be directly connected to the telephone network jacks are used for these connections This equipment should be used on party lines or coin lines this device is malfunctioning it may also be causing harm to the network this device should be disconnected until the source of problem can be determined and until repair has been made If this is not the telephone company may temporarily disconnect service The telephone company may make changes in its technical operations and if such changes affect the compatibility or use of this device the company is required to give adequate notice of the changes the telephone company requests information on what equipment is to their lines inform them of The telephone number that this unit is connected to The ringer equivalence number 0.8B The USOC jack required RJ11C and The FCC Registration Number 5QWUSA 32100 AL E b and d are indicated on the label The ringer equivalence number is used to determine how many devices can be connected to your line In most areas the sum of the RENs of all device on any one should not exceed five 5.0 If too many devices are attached they not ring properly Requirements the event of equipment malfunction all repair should be performed by our or an authorized agent It is the responsibility of users requiring to report the need for service to our Company or to one of our authorized Service can be facilitated through our office at Time Recorder Simplex Plaza MA 01441 978 632 2500 on next page Manuals Online and IC Requirements Continued Attachment The Industry Canada label identifies certified equipment certification means that the equipment meets certain network protective operational and safety as prescribed in the appropriate Terminal Equipment Requirements document s The Department does not the equipment will operate to the user satisfaction installing this equipment users should ensure that it is to be connected to the facilities of the local company The equipment must also be using an acceptable method of connection The customer be aware that compliance with the above conditions may not degradation of service in some situations to certified equipment should be coordinated by a designated by the supplier Any repairs or made by the user to this equipment or equipment may give the telecommunications company cause to the user to disconnect the equipment should ensure for their own protection that the electrical connections of the power utility telephone lines and metallic water pipe system if present are connected This precaution may be particularly important in rural Users should not attempt to make such connections but should contact the appropriate electric authority or electrician as appropriate Ringer Equivalence Number REN assigned to each terminal provides an indication of the maximum number of terminals to be connected to a telephone interface The termination an interface may consist of any combination of devices subject to the requirement that the sum of the Ringer Equivalence of all the devices does not exceed 5 on next page Manuals Online and IC Requirements Continued the FCC and or Canada Label an RS232 card is installed in the 4010 Fire Alarm Control Panel the panel be labeled to indicate this fact The label informs all persons servicing the that the panel is configured with an RS232 card and complies with FCC 68 Part No 519 749 and Industry Canada 519 751 listings To apply label do the following Refer to Figure 1 and locate the LCD Display and the Touch Pad keys it Part 68 Label and or Canada label 1 Placement for FCC Part 68 and Industry Canada Labels Notice the placement of the labels above and to the right of the LCD and the Touch Pad keys in Figure 1 Place the FCC and Industry Canada labels on the 4010 Fire Alarm Control door in the same position as that shown in Figure 1 Be sure not to vent holes Manuals Online Dual RS232 Card 4010 9811 Dual RS232 Card Part No 565 810 is connected to the N2 lines The 4010 can vector messages to RS232 ports by The RS232 ports may be configured as follows serial printers 80 or 40 column One serial printer and one CRT Keyboard command line interface RS232 ports on the option card are electrically isolated from earth allowing of an AC powered printer or CRT keyboard without causing a power Earth Fault trouble at the FACP 2 shows the location of connectors and switches Port A P7 Port B P6 Switch SW3 Rate Selection SW2 Switch SW1 Interface P2 Interface P1 2 4010 9811 Dual RS232 Card Manuals Online RS232 Service Modem Card 4010 9812 RS232 Service Modem Card Part No 565 811 is similar to the RS232 card except that one port is a dedicated Service Modem port line interface The second port Port A may be programmed for use a serial printer or left unused Event vectoring by category is supported on modem and RS232 ports RS232 port Port A on the option card is electrically isolated from earth connection of an AC powered printer without causing a power supply Fault trouble at the FACP 3 shows the location of connectors and switches Telco Jacks P8 P10 Port A P7 Switch SW3 Rate Selection SW2 Switch SW1 Interface P2 Interface P1 3 4010 9812 RS232 Service Modem Card Manuals Online Settings Address Setting SW1 cards in the 4010 system have specific addresses The card address for both the Dual RS232 and RS232 Service Modem cards is Card 4 Set to the ON position and set the remaining dip switches to the OFF the CFIG Add NEW Hardware function described in the 4010 Alarm Installation Operation Instructio

Related Files