Simplex 4010-9825 24V Distribution Block Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4010-9825-24v-distribution-block-installation-instructions-0487136592.pdf |
---|---|
Type | |
Size | 630.69 KB |
Downloads |
Text Preview
Cautions and Warnings 24V Distribution Block Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives publication shows how to wire and install the 4010 9825 24V Distribution into a 4010 Fire Alarm Control Panel FACP Refer to the 842 058 Field Diagram for additional wiring information The 4010 9825 Distribution is a module that provides additional field wiring connections for Power 24V auxiliary power The block connects to auxiliary power from the board 565 737 or 565 738 or the Expansion Power Supply 565 792 or maximum current rating for the block is 0.5 Amp from the SFI O auxiliary The block has a 2 Amp maximum current rating from each tap when to the 4010 FACP expansion power supply Wiring to the 4010 the following instructions to wire the distribution block to an auxiliary source you are using the SFI O board within the FACP to wire the block take the two steps Connect the 14 AWG Red Wire from the SFI O Board TB5 1 to the connector on the left side of the distribution block labeled 24V Connect the 14 AWG Black Wire from the SFI O Board TB5 2 to the connector on the left side of the distribution block labeled 0V The proper wiring must be fastened the Distribution Block before it is to the 4010 Chassis There is a small opening underneath SFI O board Feed the wiring this opening so the harness behind the SFI O board and up the Distribution Block mounting DISTRIBUTION BLOCK NO 4010 9825 INSTRUCTIONS 467 REV A 1 Distribution Block 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice A to the Expansion Power are two different taps on the expansion power supply that can be used when the distribution block 1 Connect the 14 AWG Red Wire from the expansion power supply TB1 1 the top connector on the left side of the distribution block labeled 24V Connect the 14 AWG Black Wire from the expansion power supply TB1 2 the bottom connector on the left side of the distribution block labeled 0V 2 Connect the 14 AWG Red Wire from the expansion power supply TB1 3 the top connector on the left side of the distribution block labeled 24V Connect the 14 AWG Black Wire from the expansion power supply TB1 4 the bottom connector on the left side of the distribution block labeled 0V the wiring is complete follow Steps 1 through 3 and refer to Figure 2 to install 4010 9825 distribution block into a 4010 FACP Keep all wiring separate from 120 VAC City Circuit and non power limited wiring Maintain at least 1 4 inch of between power limited wiring and non power limited the distribution block into the far right slot of the 4010 FACP chassis Align the screw slot at the bottom of the block with the screw hole on the Use a No 6 screw supplied to fasten the block flush against the 4010 chassis chassis can now connect external 24V wiring to the terminal block If the far right is already occupied a module use the slot located to left of the far right Expansion Supply or 565 793 2 Installing the Block into a 4010 FACP A