Simplex 4010-9826 120VAC Auxiliary Relay Kit Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4010-9826-120vac-auxiliary-relay-kit-installation-instructions-0265187349.pdf |
---|---|
Type | |
Size | 636.28 KB |
Downloads |
Text Preview
4010 9826 Auxiliary Relay Kit Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times publication shows how to wire and install the 4010 9826 120VAC Relay Kit into a 4010 Fire Alarm Control Panel FACP Refer to the Fire Alarm Installing Operating and Programming Instructions for configuration information Refer to the 842 058 Field Wiring for additional wiring information 4010 9826 Auxiliary Relay Kit is comprised of an in line fuse and a block cover The kit is used when connecting 120VAC to a 4010 SFI O 565 737 or 565 738 auxiliary relays TB6 AUX 1 or TB7 AUX 2 circuit rating is 0.5 Amp at 120VAC to Steps 1 through 5 and Figure 1 to install the in line fuse Buss Type Fuseholder Type GLQ 1 Fuse 1A 300V into the 4010 FACP Disconnect the power to the Auxiliary Relay Contacts and the 4010 FACP Wire 120VAC HOT through the in line fuse DO NOT fuse the neutral leg NOT wire 240VAC or voltages greater than 120VAC to the system Connect the other in line fuse end to the Auxiliary Relay Terminal block or TB7 Normally Open NO or Normally Closed NC Connect the Auxiliary Relay Terminal Block TB6 or TB7 Common C to LOAD Connect 120VAC NEUTRAL directly to the LOAD Route 120V in accordance with power limited Keep 1 4 inch distance from all power circuits and Warnings the Fuse 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice 1 Installing the Fuse A the Terminal Block mount the terminal block cover onto the 4010 FACP refer to Figure 2 and 1 through 4 Locate the bottom two screws of the Keyboard Mounting Plate Assembly of Partially unscrew the two screws approximately 1 16 inch Slide the terminal block cover so that the top slots of the cover hook on to 4010 FACP screws With the terminal block cover in place retighten the two screws FACP Screw 2 of Mounting Assembly Slot 2 screws A Block 2 Mounting the Terminal Block Cover