Simplex 4010 Addressable Controller

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4010-addressable-controller-6439012758.pdf
Type PDF
Size 893.87 KB
Downloads

Text Preview

UL ULC Listed FM CSFM MEA NYC Approved Model 4010 Fire Alarm Control Panel for TrueAlarm Sensors and IDNet Addressable Devices Fire Alarm Controls features include Up to 250 addressable TrueAlarm sensor or addressable points using IDNet communications that operate either shielded or unshielded twisted pair wiring Four 2 A notification appliance circuits NACs with state current protection event reporting DACT module standard on 4010 9101 4010 9102 4010 9150 listed to Standard 864 convenience features Power limited design with electronic modules contained one piece chassis Up front terminal blocks for wiring access Compact NEMA 1 rated cabinet is available in beige or and can be pre shipped for early installation programming and maintenance features Device level ground fault search locate and isolate Auto Program for general alarm operation TrueAlarm individual analog sensing with front panel and selection access TrueAlarm sensor maintenance alerts service status reports including dirty Default TrueAlarm sensor device type operation Duplicate address error detection Front panel or PC programming TrueAlarm sensor peak value performance report WALKTEST silent or audible system test Software verification simulation mode the following IDNet devices Addressable manual stations Quad state zone adapter modules ZAMs for initiating monitoring ground fault short circuit isolator base for sensors Quad state line powered individual addressable modules for initiating device monitoring and relay control option modules include Door mounted 24 LED annunciator std on ULC models Network or Point Reporting DACT Class A NAC adapter module RS 232 ports for printer and maintenance PC Additional power supply Auxiliary Relay Module or Interface Equipment for Suppression Release Applications to data sheet S4010 0003 with Simplex auxiliary panels TrueAlert Addressable Controllers and NAC power IDNet controlled and conventional 4003 Voice Control Panel 4081 Battery Cabinet with charger for 50 Ah batteries Fire Alarm Control Panel with standard door fire alarm control panels have the ability provide location accuracy for monitoring and control equipped with TrueAlarm analog sensing for and heat detection the processing power of the panel also has the ability to analyze conditions at location to provide accurate detection with reduced maintenance costs 4010 TrueAlarm Fire Alarm Control Panel has been designed to provide addressable operation and detection in a cost effective package for sizes that previously were considered only for conventional zoned monitoring and Service Ease The 4010 mounts on a chassis for quick installation and removal blocks are large and up front for easy access inspection Optional modules are easily and quickly and programmed as required 4010 cabinet provides convenient stud markers for thickness and nail hole knockouts for quicker Smooth cabinet surfaces are provided for cutting conduit entrance holes exactly where 4010 cabinets and electronics can be ordered allowing early cabinet installation Fault Assistance Ground fault problems occur during installation The 4010 provides circuitry and software controlled sequencing to ground faults to specific identified locations This helps the installer to accurately locate the problem for quicker repair Refer to page 6 for listing details This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code CSFM Listing 7170 0026 226 for allowable values and or conditions concerning presented in this document It is subject to re examination revision and possible Accepted for use City of New York Department of Buildings MEA35 93E listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Safety Products Westminster TrueAlarm analog smoke detection and IDNet addressable devices are protected by one more of the following U S Patents 5,155,468 5,173,683 5,543,777 5,400,014 5,552,763 DES 377,460 WALKTEST system test is protected under U S patent 4,725,818 10 2004 Operator Control Summary Display Panel and Diagnostic Mode Feature List The 4010 Fire Alarm Control provides access to an extensive feature list that Providing easy and powerful operator information with logical menu driven display Extensive and automatic diagnostics for maintenance History Logs available from the LCD or capable of being printed Software Verification allowing detailed logic simulation to be conducted without connected outputs Control Panel or service PC label editing Password access control Auto Program Quick Configuration Quick CFIG of modules and IDNet devices for general alarm to quickly get the system up and running Status Information With the locking closed a window allows viewing of the status The 4010 status panel provides a two line by 40 super twist LCD information display and eight LED indicators as shown in the illustration below this display the LED indicators will describe the category of activity being displayed with the LCD more detail For the authorized user unlocking door will provide access to the control switches and further inquiry by scrolling the display for detail Refer to control panel functional below Diagnostic Operation Mode The WALKTEST process allows a single person to system test The system records test inputs such intentional alarms or trouble and either logs the silent WALKTEST operation or outputs a recognizable audible notification signal audible operation Extended Operator Control Panel Functions STATUS INDICATOR LEDs provide system status indications in to LCD information LEDs flash to indicate the condition and when acknowledged remain on until reset X 40 LCD READOUT LED backlighted during normal conditions and abnormal conditions provides up to 40 characters for custom label information ALARM DISPLAY Operation can be selected for maintained display of first until acknowledged PROGRAMMABLE LEDs custom labeling labels insert into pocket the top two LEDs are as red or yellow the bottom is selectable as green or yellow VIEW with door closed TROUBLE RESET restores panel to normal when alarmed inputs are to normal ACK acknowledges a Fire Alarm condition the acknowledge and silences the operator and all annunciator tone alerts EXTENDED FUNCTION KEYS accessible with open select and scroll through display prompts for additional system information performing functions or for front panel programming ACK acknowledges system supervisory logs the acknowledge and silences the panel and all annunciator tone alerts SILENCE causes audible notification appliances be silenced used after evacuation is complete and alarm source is being investigated ACK acknowledges system troubles the acknowledge and silences the operator and all annunciator tone alerts 10 2004 Addressable Interface Analog Sensors Continued The 4010 provides IDNet addressable device Using a two wire circuit individual such as manual fire alarm stations TrueAlarm and sprinkler waterflow switches can be directly or interfaced to the IDNet controller to their

Related Files