Simplex 4010 ES Fire Control Panels; Addressable Fire Detection and Control; Basic Panel Modules and Accessories; with ESS for IDNAC Addressable Notification; for International Projects [For INTERNATIONAL USE ONLY];
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
ULC CSFM Listed NYC Fire Dept Approved Fire Control Units Addressable Fire Detection and Control Control Unit Modules and Accessories system includes Capacity for up to 1000 addressable IDNet points and to 127 VESDA Air Aspiration Systems interface with up to 2000 points of Annunciation and up to 20 internal and external card addresses Color coded operator interface with membrane keypad 2 x 40 Super twist LCD display programmable control keys and 6 programmable LEDs CPU assembly includes dedicated compact flash for on site system information storage and Ethernet service port access an Enhanced System Supply ESS that power and battery charging 6 A output Dual 3 A on board IDNAC SLCs signaling line circuit enhanced power delivery to addressable appliances With an IDNAC SLC a constant 29 VDC source is maintained during alarm even during battery allowing strobes to operate at higher voltage lower current and ensuring a consistent current and voltage drop margin under both primary power secondary battery standby Efficiencies include lower strobe currents wiring up to 2 to 3 times farther than with notification support for more appliances IDNAC SLC ability to use smaller gauge wiring all installation and maintenance savings with high that appliances that operate during normal testing will operate during worst case alarm SLCs are compatible with both TrueAlert ES TrueAlert addressable notification appliances and 4009 IDNAC Repeaters to extend power and distance even farther and extends supervisory by up to 139 additional unit loads or 3 A Addressable initiating device control is provided by IDNet 2 dual loop SLCs that provide two isolated channels that support TrueAlarm sensors and IDNet communications monitoring control devices with an electrically isolated output allowing use with either shielded or unshielded or untwisted single pair wiring and providing short circuit isolating output loops Battery charger for up to 110 Ah batteries UL or up to Ah batteries ULC 33 Ah max in control unit for 1 bay Systems 50Ah for 2 bay systems 2 A programmable function auxiliary output Remote annunciator module support via RUI Remote Interface communications port supports either B or Class A operation 48 LED panel mount annunciation provides 40 Red and Yellow pluggable LEDs select models meets ULC optional LED kits are available to change LED color to Green or Blue to meet specific requirements Cabinet Cabinet with Annunciation Cabinet Control Unit Type Reference ESS mounted modules include City Connect with or without disconnect switches Alarm Relay Module TrueInsight Remote Gateway Battery brackets for seismic area protection see page 2 block space modules include Fire Alarm Physical Bridge and Network Interface Cards Peer to Peer fire alarm network communications either Class B or Class X operation Ethernet connectivity options include Building Network Module BNIC SafeLINC Internet Interface and Ethernet Portal Dual Class A IDNAC Isolator DCAI Dual RS 232 Module VESDA Air Aspiration High Level Interface Serial DACT 8 Zone IDC Modules Class A or B 4 Point Auxiliary Relay Module Additional IDNET addressable channels with Simplex remotely located 4098 9757 QuickConnect2 and legacy 4098 9710 TrueAlarm smoke sensors 4003EC Small Voice Units 4081 Series 110 Ah Battery Chargers 4100 7400 Series Graphic Annunciators 4190 Series PC Annunciator 4190 Series Fiber Modems and Physical Bridges 4606 9102 Remote LCD Annunciator 4100 9400 Series InfoAlarm Command Centers and 4602 Series Command Units SCU and Remote Command RCU Annunciators communicator compatibility See page 6 for additional listing information This product has been approved by the California Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7165 0026 0369 for allowable values and or conditions concerning presented in this document NYC Fire Dept COA 6193 Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection Products 12 2016 Agency listings UL 864 Control Units System UOJZ Control Unit System Fire Alarm UOXX Control Releasing Device Service SYZV Smoke System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UL 2017 Emergency Alarm System Control Units detection FSZI Process Equipment Management ULC S527 Control Units System Fire Alarm Control Unit Accessories System Fire UOXXC Control Units Releasing Device SYZVC Smoke Control System Equipment ULC S559 Central Station Fire Alarm System Units CSA 6.19 Gas Alarms and Accessories CZHFC ULC ORD C1076 Proprietary Burglar Alarm Units APOUC ULC ORD C100 Smoke Control System Equipment Series Fire Detection and Control Units leading edge installation operator and service for customer applications in the mid range fire alarm systems market An on board port provides fast external system to expedite installation and service Dedicated compact flash memory archiving secure on site system information storage of job configuration files to meet NFPA 72 Fire Alarm and Signaling Code requirements design A variety of functional modules are to meet specific system requirements Selections control units to be configured for either or Networked fire control operation Command Center options provide convenient display content detailed on data sheet S4010 Mechanical Description Mounting box provides convenient stud markers for thickness and nail hole knockouts for quicker Smooth box surfaces are provided for locally cutting entrance holes exactly where required The hinged User Interface panel easily opens for Modules are power limited except as noted such as access modules Doors include tempered glass inserts boxes and doors available in platinum or red Description Continued Box and door retainer assemblies are included with control unit assemblies Cabinet assemblies are rated NEMA 1 and IP 30 Cabinet assembly design has been seismic tested and certified to IBC and CBC standards as well as to 7 categories A through F requires battery as detailed on data sheet S2081 0019 Unit Hardware Master Controller and Enhanced System ESS are mounted in the upper section of the cabinet refer to one and two bay loading diagrams on page 10 Block Space Option Cards mount to the left the 4010ES ESS In 2 bay cabinets block space option also mount below the 4010ES ESS 4010ES Options The 4010ES City Connect or the optional Alarm Relay module mount to the ESS These options are mutually exclusive TrueInsight Remote Gateway mounts on the back of the 4010ES User Interface Panel Media modules mount directly to the 4010ES Interface Card battery compartment is located in the bottom of 4010ES cabinet The cabinet allows for up to 33 battery capacity for 1 bay systems and 50Ah for 2 systems 50Ah batteries also require the use of battery shelf Feature Summary TrueAlarm individual analog sensing with front panel and selection access TrueAlarm sensor maintenance alerts service status reports including dirty TrueAlarm magnet test indication appears as distinct abnormal message on display when in test mode TrueAlarm sensor peak value performance report Mode allows grouping of multiple tr