Simplex 4010 Expansion Power Supplies Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings Expansion Power Supplies Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area may cause in which case the user at his own expense will be required to take measures may be required to correct the interference 120V and 4010 9823 240V Expansion Power Supplies provide of battery backed power limited notification power The output of the power supply can be harnessed to notification circuits on the 4010 Alarm Control Panel FACP SFI O board publication shows how to install the 4010 9813 and 4010 9823 Expansion Supplies into a 4010 FACP Only one of these expansion supplies is per system For more information on the 4010 FACP and expansion supplies refer to the 4010 Fire Alarm Front Panel Installing Operating Programming Instructions 574 052 Refer to the Field Wiring Diagram for additional wiring information Page and 9823 Expansion Power Supplies and Checkout this Publication publication discusses the following topics 1999 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice D and 9023 Expansion Power Supplies expansion power supply provides a maximum of 4A of filtered 24VDC This power can be distributed between each of the following four with no circuit drawing more than 2A NAC Circuit 3 NAC Circuit 4 Circuit 1 TB1 1 and TB1 2 on the expansion power supply Circuit 2 TB1 3 and TB1 4 on the expansion power supply 4010 9813 120V and 4010 9823 240V expansion power supplies have own dedicated hardware slot See Figure 2 See Figure 1 for all connector Connector White Harness Connector Red Harness Leads AUX Power Output maximum via two 2A taps 1 4010 Expansion Power Supply 4010 9813 and 9823 Expansion Power Supplies install in their own slot located to the right of the 4010 SFI O module see Figure 2 Use 1 through 3 to mount an expansion supply Disconnect battery and then AC power from the FACP With TB1 of the expansion power supply in the bottom position slip the top of the expansion supply metal bracket over the flanges located on the chassis Use the supplied slotted Torx screws Part No 441 002 and lock washers secure the expansion supply bracket to the chassis The yellow and orange wires on the expansion power supply have no on the FACP They must be neatly tucked out of the way to hook chassis Red and P14 Expansion Connectors Screw 2 2 4010 Expansion Supply Hardware Slot Wiring the following information to wire the expansion power supply For information reference the 526 407 and 526 408 labels inside the and the 842 058 Field Wiring Diagram Pay careful attention to the routing for power limited non power limited wiring You must maintain a separation between these two types of Steps 1 through 4 to wire AC power to the 4010 9813 or 9823 Power Supplies Disconnect battery and then AC power from the FACP Remove the existing AC harness from the FACP Now remove the connector from the chassis by firmly gripping the release and pulling it free The quick disconnect connector is located directly the chassis The quick disconnects on the AC Harnesses are not for quick disconnect while power is applied should be turned OFF at the breaker box disconnecting the AC Power quick disconnect Remove the harness wiring from the AC terminal block located in the lower corner of the 4010 back box Wire the 733 949 4010 9813 120V Supply or the 733 955 4010 9823 Supply harness to the back box terminal block Match incoming and Hot wires to their corresponding wires The wires lead from terminal block located in the lower right corner of the back box to the harness and screw into place NOT APPLY POWER TO THE 4010 AT THIS TIME NOT connect the quick disconnect AC to either the expansion power supply or main chassis Refer to the and section of this publication on next page Continued and Power Wiring expansion power supplies require power and communications connections the 4010 SFI O board Use Steps 1 through 3 to connect a power and harness from the expansion supplies to the 4010 FACP Both connectors are keyed for correct connection Connect the 733 950 white harness from P2 of the expansion supply to P14 Connect the 733 951 red harness from P1 of the expansion supply to P13 of the SFI O board SFI O board This connection is optional It is only needed if you want to power 3 and 4 on the 4010 FACP from the expansion power supply of the 4010 FACP System Power Supply Neatly dress the wiring behind the 4010 chassis using the holes provided to the harnesses expansion power supplies require connection to the battery terminals TB8 the 4010 SFI O board Connect the red battery lead from the expansion supply to the terminal TB8 on the SFI O This connection is optional If no battery backup is required for the Power Supply you do not need to connect this red wire you still must connect the black wire Connect the black battery lead from the expansion supply to the terminal TB8 on the SFI O and Checkout AC and Battery Panel Programming must enable the expansion power supply via the 4010 FACP Follow Steps through 6 to program the 4010 FACP to accept the expansion power supply the following steps to apply AC and battery power to the 4010 FACP Connect the appropriate dual AC harness to the bottom of the expansion supply first and then to the bottom of the main FACP chassis Apply AC power at the breaker box Connect the crimped ends of the 733 945 battery harness to the batteries polarity red to black to when connecting batteries contains sulfuric acid which can cause burns to the skin and eyes and can destroy Replace any leaking or damaged battery If is made with sulfuric acid immediately flush or eyes with water for 15 minutes and seek medical attention applying power to the system use the following list to check the 4010 for operation Ensure the green AC power LED is ON Ensure all yellow and red LEDs are OFF Whenever possible schedule an alarm test with the building owner to verify power supply operation during an alarm load condition Log in to the 4010 FACP at Level 4 Simplex Service Mode Press the MENU button and then the NEXT or PREVIOUS button Programming is displayed Press ENTER Press the NEXT or PREVIOUS button until System Options is Press ENTER Press ENTER Press the NEXT or PREVIOUS button until Expansion Power is Press the NEXT or PREVIOUS button until NEW ON is displayed ENTER to update the option Save your CFIG with the new settings now in place the following notes as reference information for installing the expansion supply The SFI O board monitors two circuits for trouble condition Comparators the expansion power supply are used to monitor the output of each tap after the PTC and the battery input The AUX power

Related Files