Simplex 4010 Series; 4090-9005 9006 Release Control for the 4010 Fire Alarm System; includes Suppression Release Peripherals and associated accessories (C)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Control Fire Alarm Systems Control Systems Reference for the Fire Alarm Control Panel control using the Simplex 4010 Fire Control Panel to provide Coverage for up to 10 hazard areas of Automatic Release and or Deluge and Preaction System Release Releasing Appliance Circuit RAC control of Listed Approved 24 VDC automatic control one per circuit or two 12 VDC actuators in per circuit RAC provides short circuit supervision to coil module Four 2 A Notification Appliance Circuits NACs in the for use with Suppression Release Peripherals SRP Additional actuator circuit control and additional NACs available using 4009 IDNet Addressable NAC and Suppression Release Peripherals Escalation of Events Temporal or 20 bpm March Time pattern for first 120 bpm March Time pattern to indicate releasing timer alarm On steady to indicate releasing timer expired and is activated NOTE Requires NACs dedicated to conventional horn not SmartSync operation with strobes on separate NACs IDNet NAC Extenders provide Up to eight NACs for notification requirements and for input to Suppression Release Peripherals Control is via IDNet addressable communications Suppression Release Peripheral Dual Command Control Dual command control requires that both IDNet commands and an activated NAC are to initiate the desired release NAC provides wiring supervision to the actuator monitoring of coil continuity Release Peripheral control features An on board DC DC regulator compensates for drops to the peripheral and ensures proper circuit voltage over a wide operating range Provides a single RAC for control of actuators for up 1 A using a 2 A NAC input system components 4010 Series control panel with Releasing Appliqu Dedicated NAC output from 4010 or NAC Extender Coil supervision module one per RAC Maintenance Switch one per RAC Abort Switch connected via an addressable interface listed to Standard 864 Control Circuit supervisory NAC NAC SUPERVISION MODULE 2 AMP 2081 9046 INSTRUCTIONS 574 437 REV 1 4 SEPARATION POWER LIMITED AND NONPOWER YEL BLK WIRING CODE PLEX TIME RECORDER CO GARDNER MA USA circuit Switch indicator lamp SUPPRESSION DISABLE Peripheral devices SUPPRESSION ABORT AND HOLD IDNET IN IN for lamp required circuit SYSTEM IS NORMAL 12 02 15pm Mon 8 Mar 99 TROUBLE RELEASE PANEL This Control Unit has been arranged for releasing Disable all releasing device circuits prior to servicing ALARM NECT BEFORE VIC ING Control Panel with Release Appliqu Series Releasing Control Typical Block Diagram 4010 series fire alarm control panel is capable of actuators for use in automatic extinguishing deluge or preaction releasing systems IDNet communications are used to monitor initiating and for control of 4009 IDNet NAC extenders Suppression Release Peripherals Releasing system is implemented within the 4010 control panel as for the local application 4010 Releasing Control has been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM 7170 0026 226 and 7300 0026 313 for allowable values and or conditions material presented in this document It is subject to re examination revision possible cancellation Accepted for use City of New York Department of Buildings MEA35 93E Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co the property of Tyco Safety Products Westminster This document describes features available with 4010 software revision 3.01 or higher to data sheet S4010 0001 for model 4010 control panel details including IDNet information IDNet addressable communications are protected by U S Patent 4,796,025 3 2007 Automatic Extinguishing Release Systems systems automatically activate electrically actuators for the release of a fire extinguishing such as dry chemical water spray foam CO2 or agent in response to fire detection device inputs as by programming of the host fire alarm control Extinguishing Release System Panels required to have a minimum of 24 hours of standby Initiating devices must be Listed Approved for the and may be wired either Class A or B actuators must be electrically compatible with the panel circuits and power supplies and are wired B to provide coil supervision or Preaction Sprinkler Systems systems automatically activate water control in response to fire detection device inputs Sprinkler Systems employ open sprinkler and provide water flow when the fire detection activates a common automatic water control They are used to deliver water simultaneously all of the system sprinkler heads This type of is applicable where the immediate application of quantities of water over large areas is the proper fire Sprinkler Systems are similar to deluge except that normally closed sprinkler heads are and supervisory air pressure is maintained in the Operation requires both an activated sprinkler head an activated fire alarm initiating device with specific determined at the host fire alarm control System Requirements Releasing actuators are controlled from a Release Peripheral 4090 9005 or Connections are 2 wire Class B releasing with only one 24 VDC actuator per circuit applicable two 12 VDC actuators in series or 12 VDC actuator with manufacturer supplied may be used Coil Supervision Module 2081 9046 must be wired before the actuator and located in the wiring junction box Refer to diagram on 5 The connected RAC provides continuity of the actuator coil and wiring and short circuit supervision to the coil module Cross zoning or other alarm initiation logic per requirements is to be implemented by at the fire alarm control panel UL Listed Automatic Extinguishing Releasing requires that battery standby must be a of 24 hours with 5 minutes of alarm and that actuators are used refer to list on page 6 Releasing System Requirements Continued FM Approved Automatic Extinguishing Release secondary standby to be a minimum of hours with 5 minutes of alarm Actuators must be compatible FM Approved Deluge and Preaction Sprinkler requires that initiating device circuits be A and wired to Listed Approved devices power capacity must be a minimum of 90 with 10 minutes of alarm and that approved Water Control Valves must be used Refer actuator list on page 7 Maintenance Switches one per RAC are required NFPA 72 the National Fire Alarm Code 2002 Chapter 6 to allow the system to be tested or without actuating the fire suppression Their use may not be allowed in some always confirm local requirements used Simplex Maintenance Switches are to ensure that operation initiates a condition Abort Switches are available when abort operation is When used connect to an addressable IAM model 4090 9001 or similar adapter module The Simplex abort switch the IAM mount in a single gang box 2 1 2 depth Addressable Manual Releasing Stations are used to activation of the releasing actuators with the time delay implemented

Related Files