Simplex 4010 SFIO Board Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4010-sfio-board-installation-instructions-0219583674.pdf
Type PDF
Size 800.29 KB
Downloads

Text Preview

Cautions and Warnings the Panel the SFIO Board SFIO Board Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times publication shows how to replace an existing SFIO board in a 4010 Fire Control Panel FACP with a replacement SFIO board Part No 565 737 or 565 738 Canada For additional wiring information please refer to the Fire Alarm Installing Operating and Programming Instructions 574 052 4010 FACP must be reconfigured for the replacement SFIO board Take following steps to complete the upload the existing SFIO board is still functional upload the CFIG OR you are unable to upload the CFIG from the existing SFIO use an CFIG disk OR you are unable to either upload the CFIG from the FACP or from an CFIG disk use the AUTO CFIG feature and the 4010 Front Panel PC Programmer to restore the original CFIG data base functionality from copy records Refer to the 4010 Fire Alarm Panel Programmer Installation and Instructions 574 187 for additional programming remove the SFIO board from a 4010 FACP follow Steps 1 through 14 and to Figures 1 and 2 Remove AC Power from the FACP at the breaker Using a Key unlock and open the door assembly on the 4010 FACP Remove the retainer from the panel Disconnect the FACP batteries Check Aux 1 and Aux 2 terminals for any external from field wiring Remove the voltage at the before attempting to disconnect field wiring to remove the SFIO Mark and remove all field wiring and internal wiring from the SFIO board 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice A the SFIO Board Using needle nose pliers disconnect P9 Orange wire and P10 Yellow on the left hand side of the SFIO board Using a T 15 Torx driver unscrew the four No 6 screws that connect the mounting plate assembly to the SFIO mounting plate Place the and washers aside Gently lift the keyboard mounting assembly straight upward Disconnect keypad harness connecting the keyboard mounting assembly to the SFIO P11 Set the keyboard mounting plate assembly aside Remove the four hex posts that hold the keyboard plate in place Using a T 15 Torx driver unscrew the four No 6 screws that connect the mounting plate to the 4010 chassis Set the washers and screws aside Gently lift the SFIO mounting plate from the 4010 chassis Locate the bridge rectifier on the back of the SFIO mounting plate Using pliers disconnect the Brown and Blue wires connected to the rectifier and then disconnect the Red and Black wires connected to bridge rectifier Using a T 15 Torx driver remove the No 6 screw and washer located in the right hand corner of the SFIO board Set the screw and washer aside With all the wiring removed from the SFIO Board Assembly and the plate take the assembly to a flat surface With a flat blade gently dislodge the SFIO board from the SFIO mounting plate the SFIO board aside Box Rectifier back of Plate Assembly Mounting Plate Board Assembly Mounting Assembly 1 Expanded View of a 4010 FACP the SFIO Board install the replacement SFIO board into a 4010 FACP follow Steps 1 14 and refer to Figures 1 and 2 On a flat surface align the replacement SFIO board over the SFIO mounting assembly Gently push the board down until it snaps into place Replace the screw and washer on the top right hand corner of the SFIO card Reconnect the SFIO Bridge Harness Red wire from H1 to the Bridge and Black wire from H2 to the bridge terminal Reconnect the transformer connections to the bridge rectifier Connect the and Blue wires from the transformer to the bridge terminals 6 Screw on the Board board 733 965 to P13 Red if an expansion power is NOT installed 2 4010 Interconnection Drawing Note the SFIO Board Align the SFIO board mounting plate assembly over the 4010 chassis so that four holes of the mounting plate are in line with the holes on the chassis Screw the SFIO mounting plate assembly onto the FACP chassis using the four No 6 screws and washers Replace hex posts for the display mounting plate With the SFIO mounting plate assembly in place align the keyboard assembly over the SFIO board assembly Reconnect the harness the SFIO Reconnect the assembly headers to the SFIO connector s Attach the keyboard mounting assembly to the SFIO mounting plate using the four original No 6 screws and washers Reattach all field wiring and internal wiring to the SFIO board assembly in the lower left corner of the SFIO must not each other or any other metal surface Check the Baud rate settings Reapply power to the 4010 FACP Connect the AC power first and then battery power Verify that all FACP operations work properly Re install the retainer into the panel A

Related Files