Simplex 4010 Suppression Release Kit Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings Suppression Release Kits Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area is likely to cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install the 4010 9814 120V and the 4010 9824 Suppression Release Kits into a 4010 Fire Alarm Control Panel FACP to the 4010 Fire Alarm Installation Instructions 574 052 for information Refer to the 842 058 Field Wiring Diagram for wiring information Page and 9824 Suppression Release Kits and Checkout this Publication publication discusses the following topics 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice B and 9824 Suppression Release Kits the suppression function is controlled by the 4010 Fire Alarm Control a Suppression Release Kit power supply 565 793 can be added to power for this function The suppression release kit provides 24VDC 4A power for Notification When controlling the release function a Notification Appliance Circuit is limited to a single valve 1 and 2 are rated at 2A 24VDC Tap and Terminal 3 and 4 are at 2A 24VDC Tap Maximum wire length is 3,270 feet Be sure to Auxiliary 24VDC in battery standby considerations See Figure 1 for locations Connector White Connector Red Leads AUX Power Output MAX R 1 4010 Suppression Release Kit 4010 9814 and 9824 Suppression Release Kits install in their own slot located to the right of the 4010 SFI O module see Figure 2 Use 1 through 3 to mount the suppression release kit Disconnect battery and then AC power from the FACP With TB1 of the suppression release kit in the bottom position slip the top of the suppression release kit metal bracket over the flanges located the 4010 chassis Use the supplied slotted TORX screws Part No 441 002 and lock washers secure the other end of the suppression release kit bracket to the chassis Class A Module 565 789 Class A Module 565 789 Pot for LCD Adjustment Module 4010 9820 Module 4010 9825 Extender Terminal Block Power 565 792 Power 565 793 PTCs MUST NOT TOUCH EACH OTHER OR ANY OTHER METAL SURFACE Supply Slot Red and P14 Expansion Connectors 2 4010 Suppression Release Kit on next page the suppression function is controlled by the 4010 Fire Alarm Control the panel must be labeled to indicate this fact The label lets all persons the system know that the panel is configured for suppression release that they must disable all releasing device circuits before servicing the panel apply the label do the following Refer to Figure 3 and locate the LCD Display and the Touch Pad keys it Continued the Suppression Label Label Notice the placement of the label below the LCD Display and the Touch keys in Figure 3 Place the Suppression Release Label on the 4010 Fire Alarm Control Panel in the same position as that shown in Figure 3 Wiring the following information the 526 407 and 526 408 labels inside the FACP the 842 058 Field Wiring Diagram to wire the suppression release kit Pay careful attention to the routing for Power Limited Non Power Limited wiring You must maintain a separation between these two types of wiring Steps 1 through 4 to wire AC power to the 4010 9814 or 9824 release kit Disconnect battery and then AC power from the FACP Remove the existing AC harness from the FACP Remove the Quick connector from the chassis by firmly gripping the release tabs pulling it free The Quick Disconnect connector is located directly the chassis The Quick Disconnects on the AC Harnesses are not for Quick Disconnect while power is applied should be turned OFF at the breaker box disconnecting the AC Power Quick connectors Remove the harness wiring from the AC terminal block located in the lower corner of the 4010 back box Wire the 733 949 4010 9814 120V supply or the 733 955 4010 9824 supply harness to the back box terminal block Match incoming and Hot wires to their corresponding wires leading from the block located in the lower right corner of the back box to the harness and screw into place DO NOT APPLY POWER TO THE 4010 AT THIS TIME NOT connect the quick disconnect AC connectors either the suppression power supply or the main Refer to the and Checkout of this publication on next page Continued and Power Wiring suppression release kit requires power and communications connections to 4010 SFI O board Use Steps 1 through 3 to connect a power and harness from the suppression release kit to the 4010 FACP harness connectors are keyed for correct connection Connect the 733 950 white harness from P1 of the suppression release kit Connect the 733 951 red harness from P2 of the suppression release kit to Neatly dress the wiring behind the 4010 chassis using the holes provided to P14 of the SFI O board of the SFI O board the harnesses suppression release kit requires connection to the battery terminals TB8 on 4010 SFI O board Connect the red battery lead from the suppression release kit to the of TB8 on the SFI O Connect the black battery lead from the suppression release kit to the of TB8 on the SFI O and Checkout AC and Battery the following steps to apply AC and battery power to the 4010 FACP Connect the appropriate dual AC harness to the bottom of the suppression kit first and then to the bottom of the main FACP chassis Connect the crimped ends of the 733 945 battery harness to the batteries polarity red to black to when connecting batteries Battery contains sulfuric acid which can cause severe to the skin and eyes and can destroy fabrics any leaking or damaged battery If contact is with sulfuric acid immediately flush skin or eyes water for 15 minutes and seek immediate medical applying power to the system use the following list to check the 4010 for operation Check that the green AC Power LED is ON Check that all yellow and red LEDs are OFF Use the Lamp Test procedure in the Operation Chapter of this publication to that all 4010 LEDs and LCD segments work properly B

Related Files