Simplex 4090-5201, 4090-5202, 4090-5203, 4090-5204, 4090-5205, 4090-5206, 4081-9020, 4081-9021, 4081-9022 MX Technology Addressable Devices – IAMs, Monitor ZAMs, and Line Isolator
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
Listed Technology addressable input output features Mini IAMs Individual Addressable Module provide monitoring of a single input and have a small suitable for convenient mounting Dual Input IAMs provide remote monitoring of two B inputs or one Class A input Relay IAMs provide remote relay contact control Signal IAMs combine with 24 VDC to provide a 2 A Class B or Class A operation Notification Circuit NAC Monitor ZAMs Zone Adapter Module provide local Device Circuit IDC operation either dual B IDCs or single Class A IDC Line Isolator Modules monitor line condition and input from output to isolate short circuits Address is easily programmed with the MX Service Modules except 4090 5201 Mini IAM are mounted a cover assembly that provides access to the address port and allows viewing of the LED status Modules with covers mount in a standard dual gang box UL listed to Standard 864 For use with Simplex 4100ES 4010ES and 4100U fire alarm control panels equipped with an MX Module Refer to data sheet S4100 0059 for MX Loop Module MX Technology addressable I O input output provide flexible monitoring and control to satisfy variety of applications Each is individually addressable communicates with an MX Loop Module located in host fire alarm control panel Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products Technology Addressable Devices IAMs Mini Dual Signal and Relay ZAMs and Line Isolator Modules MX Technology I O Module Assemblies Details Mini IAM Mini IAM Individual Addressable Features Small size for single input circuit monitoring of open or normally closed contacts Provides open and short circuit monitoring of the line Fits in small devices such as flow switches special devices and explosion proof callpoints A variation of this module is used in addressable and pull stations Dimensions are 1 W x 2 5 H x D mm x 58 mm x 13 mm mounted separately from the device being select electrical box with cover plate per above 3 2012 Product Details Continued Dual Input IAM Dual Input IAM Features Two separately wired Class B spur inputs providing and short circuit line monitoring that can be for one Class A input Each can be configured to monitor normally open or closed inputs Both inputs can be configured to initiate an alarm or circuit fault message in the event of a short on normally open monitoring circuits Monitor ZAM Monitor ZAM Zone Adapter Module Provides monitoring and zone power for two Class B or one Class A circuit of low voltage detectors and callpoints External 24 VDC power is supplied from a 4100 5130 Regulator Module in the controlling host fire panel 24 VDC status is monitored and a fault signal is if lost Power reset is controlled from the MX Loop module the host fire control panel detection circuit can be wired as one or two spur Class B or one 4 wire detection circuit Relay IAM Relay IAM Features A single relay output programmable from the MX Applications include signaling fire conditions to plant fire doors dampers and security systems Relay coil is monitored Relay contact is rated for 2A 24V DC Signal IAM Signal IAM Features Remote addressable NAC spur can be wired Class B Class A and is rated 2A 24V DC for up to 62 requires a separately wired 24 VDC input Can also be used to provide a supervised output for control applications Line Isolator Module Line Isolator Module Features Monitors the MX Loop line condition for short and provides connection isolation using solid switches A spur circuit is connected between the input and switches for connection convenience A fault on either the input Left side wiring or the Right side wiring opens that switch allowing spur to continue to operate for loop circuits wired A and also isolates the shorted wiring section the functioning section A fault on the spur circuit opens both switches the spur from the rest of the loop 3 2012 Dimension and Installation Reference and Bottom View Reference 4090 5202 4090 5203 4090 5204 4090 5205 4090 5206 holes 2 Status Indicator setting port mm mm 9 mm into box 148 mm View with typical module without module cover for reference 3 2012 Product Selection Input Output Modules refer to specific module details on pages 2 and 3 Mini IAM supervised contact monitoring module Dual Input IAM dual Class B or single Class A supervised contact monitoring module Relay IAM contact rated 2 A 24 VDC A monitoring requires EOL resistor assembly 4081 9020 IAM two Class B NACs or one Class A NAC rated 2 A 24 VDC up to 62 Class A output requires EOL resistor assembly 4081 9022 Refer to the Installation Instructions for compatible notification appliances ZAM two Class B inputs or one Class A input Class A input requires EOL resistor 4081 9021 Regulated power is required use the 4100 5130 Voltage Module in the host panel Refer to the Installation Instructions for two wire detector compatibility information Isolator Module Instruction 1 W resistor k 1 W resistor k 1 W resistor listed Four Wire End of Line Resistor Harness Assemblies provides two input and output color coded wire leads red black for in out wiring with an across the line leads are 6 long 152 mm with resistor and terminations insulated Remote LED on single gang stainless steel plate optional for use with 4090 5201 Mini IAM Replacement Module Front Cover MX Service Tool ref MX Model 801AP MX Ancillary Program Lead Spare MX Service Tool Accessory Kit Specifications to additional specifications on pages 1 2 and 3 Monitor ZAM Loop Current Voltage voltage 24 VDC from 4100 5130 Voltage Regulator Module the host fire alarm control panel voltage 21.9 VDC voltage 26.4 VDC from MX Loop Class B standby 0.28 mA Class A standby 0.53 mA from External VDC Supply Does not include current Mini IAM Dual Input IAM 4090 5203 Relay IAM Signal IAM Isolator Module B standby 14 mA Class A standby 8.25 mA B or Class A alarm 50 mA per detector spur circuit detector voltage 18 VDC maximum detector voltage 25 V standby detector load per 4090 5205 2.8 mA Resistor for Class B spur circuits 4.7 k circuit resistance 50 mA in standby or in alarm without remote LED mA in alarm with remote LED mA in standby mA in alarm mA in standby mA in alarm mA in standby mA with single trip 10 mA with double trip fault on spur circuit box for each full size module applicable to the 4090 5201 Mini IAM resistance to monitored circuits Connections Temperature 2 gang MK box maximum blocks for wire size 20 to 14 AWG 0.5 to 2.5 mm2 F to 120 F 0 C to 49 C to 93 RH at 90 F 32 C SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2011 T