Simplex 4090-9002 IDNet Relay IAM, for use with 4100ES 4100U, 4010ES, 4008, and 4010 IDNet communications (B)

File Preview
File Preview
Click below to download for free

Text Preview

ULC Listed FM CSFM MEA NYC Approved Peripherals IDNet Communicating Devices 4090 9002 Relay IAM Addressable Relay Module Relay addressable control for use with Simplex fire control panel models 4100ES 4100U 4010ES and 4010 A single addressable point provides control and status of a Form contact Low power latching relay design allows IDNet to supply both data and module power sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 102 mm square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be after installation listed to Standard 864 Relay IAMs allow fire alarm control panels to a remotely located Form contact using IDNet communications for both data and module Typical applications would be for switching local for control functions such as elevator capture or of HVAC components pressurization fans etc Relay status is also communicated requiring one device address Selection Relay IAM Trim Plates For semi flush box For surface box plate galvanized with LED viewing includes screws This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products IDNet Relay IAM Package approximately 1 2 size communications 1 address per IAM Power Supplied by IDNet communications Ratings not rated for incandescent switching C SPDT A 24 VDC resistive A 24 VDC inductive listed alarm 0.5 A 120 VAC resistive Provide circuit fusing and transient suppression as per application DC inductive loads can typically diode suppressed 120 VAC loads may require RC or varistors depending on device type Refer to Instructions 574 184 for additional information Connections Screw terminals for in out wiring to 14 AWG wire 0.82 to 2.08 mm2 to 2500 ft 762 m from control to 10,000 ft 3048 m total wiring including T Taps with Simplex 2081 9044 Protectors H x 4 W x 1 D mm x 105 mm x 35 mm Reference Material Black thermoplastic Plate Range metal galvanized to 120 F 0 to 49 C for indoor operation to 93 RH at 100 F 38 C 12 2012 Relay IAM Mounting Information setting under label 102 mm square box 2 1 8 mm minimum depth RACO or equal supplied by others Relay IAM gang blank cover plate and mounting screws for when LED is not required to be externally viewed by others Reference Double Gang Blank Cover Plate mm mm pipe for LED viewing 116 mm 109 mm Trim plate for mounted box Trim plate for mounted box Trim Plates for Visible LED SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2012 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 11 2012

Related Files