Simplex 4090-9051 IDNet or MAPNET II Supervised IAM (B) (C)

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4090-9051-idnet-or-mapnet-ii-supervised-iam-b-c-5469137082.pdf
Type PDF
Size 797.78 KB
Downloads

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals and MAPNET II Communicating Devices Addressable Modules IAMs or MAPNET II addressable communications both data and power over a single wire pair provide Supervised Class B monitoring of normally open dry Total wiring distance from IAM to supervision of up to 500 ft 152 m Monitored connection is compatible with Simplex Overvoltage Protectors for outdoor wiring or noisy applications For use in indoor locations up to 158 F 70 C such as spaces or similar applications use with following Simplex control panels Model Series 4008 4010 4010ES 4100U and 4100ES alarm control panels for IDNet communications Model Series 4100 4100U 4100ES 4120 4020 and Communicating Device Transponders CDTs with MAPNET II communications 4090 9001 Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be after installation requires mounting bracket separately 4090 9051 Encapsulated design for extended exposure to high LED is not present on this model Color coded 18 AWG leads for wiring communications provides current limited Provides monitoring of tamper switch supervisory waterflow switch alarm on same circuit using point Available with IDNet communications only operation modes are available and are at the control panel Contact closure status can be tracked Momentary contact closure conditions can be selected at panel to be latched or tracked not available with the CDT listed to Standard 864 These products have been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Supervised IAM approximately 3 4 size Supervised IAM approximately 3 4 size addressable modules IAMs receive power and communications from a two wire II or IDNet circuit They provide location addressability to a single initiating device such single station smoke detector alarm contacts or heat contacts or multiple devices at the same location monitoring normally open dry contacts and the wiring an end of line resistor 4090 9001 is packaged in a thermoplastic and provides screw terminal connections and a indicating LED 4090 9051 is an encapsulated package with wire It does not provide a status indicating LED IDNET IN IDNET IN LISTEDSIGNALING DEVICEISSUE NO firealarmresources com Closure Closure of the monitored contact s an alarm or other response as programmed at the alarm control panel An open in the monitored circuit will cause a trouble to be reported Selections Selections can be made at the control to maintain the alarm condition if the initiating contacts are momentary such as from a heat detector or to track the device contact not available with the 2120 CDT IAM Product Selection Limited Operation Applications use with IDNet communications only these can provide quad state sensing of normal open short circuit and current limited conditions type is With the proper end of line current limiting resistors dual functions such as switch and waterflow switch monitoring can be and communicated by a single addressable Supervised IAM mounted in thermoplastic housing with screw terminals see applicable options below Supervised IAM encapsulated with wire leads Trim Plates and Mounting Bracket for Model 4090 9001 For semi flush mounted box For surface mounted box plate with LED viewing window requires 4090 9810 mounting bracket mounting screws galvanized steel bracket mounts IAM to electrical box and provides screw holes for trim plate required for optional trim Resistor Harnesses ordered separately as required No Description k 1 2 W Standard end of line resistor harness for N O contact supervision k 1 2 W k 1 2 W for current limited monitoring applications Specifications Connections Documents Distances from IAM to Contacts and Communications II or IDNet auto selected 1 address per IAM Requirements open dry contacts terminals for in out wiring 18 to 14 AWG wire mm2 to 2.08 mm2 Color coded wire leads 18 AWG 0.82 mm2 8 long 203 mm Instructions 574 331 for 4090 9001 579 572 for 4090 9151 Wiring Diagrams 842 073 for IDNet operation 841 804 for MAPNET II operation ft 152 m maximum without protectors ft 122 m maximum with 2081 9044 Overvoltage Protectors ft 762 m maximum from fire alarm control panel ft 3048 m maximum total wiring distance including T Taps Distance Reference per channel MAPNET II or Communications 1 9 16 W x 1 3 4 H x 1 1 4 D 40 mm x 44 mm x 32 mm 1 9 16 W x 1 9 16 H x 9 16 D 40 mm x 40 mm x 14 mm Material 4090 9001 thermoplastic Material 4090 9051 beige Range Range to 158 F 0 to 70 C intended for indoor operation to 93 RH at 100 F 38 C Mounting Information Trim Plates and Mounting Bracket for Visible LEDSingle gang electricalbox 2 1 2 64mm minimum depth supplied by others Single gang blank cover plate and mounting screws for use whenLED is not required to be externally viewed supplied by others 4090 9001 IDNetsupervised IAMField wiring shownfor referenceAddress setting under resealable label IDNET IN IDNET IN LED viewing port4090 9806 Trim plate for semi flush mounted box4090 9807 Trim plate for surface mounted box4 1 4 108 mm 2 1 2 64 mm 2 13 16 72 mm 4 1 2 114 mm Light pipe forLED viewingNOTE These mounting plates require mounting bracket 4090 9810.4090 9810 Mountingbracket orderedseparatelyMounting Reference Single Gang Blank Cover Platefirealarmresources com 4090 9051 Mounting Information is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo IDNet and MAPNET II are trademarks of Tyco Ltd and its affiliates and are used under license LP Westminster Westminster MA 01441 0001 USA 2011 Tyco All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice gang electricalbox 2 1 2 64mm minimum depth supplied by others Single gang blank cover plate andmounting screws supplied by others 4090 9051EncapsulatedSupervised IAMAddress setting isat rear of housingLISTEDSIGNALING DEVICEISSUE NO firealarmresources com

Related Files