Simplex 4090-9116 Addressable IDNet Communications Isolator
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4090-9116-addressable-idnet-communications-isolator-5724890613.pdf |
---|---|
Type | |
Size | 802.77 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance port bi directional communications short isolator Compatible with Simplex 4007ES 4008 4010ES or 4100U Series fire alarm control panel Signaling Line Circuits SLCs providing IDNet IDNet 1 IDNet 2 or IDNet 2 2 loops see additional information on pages 2 3 Either port can serve as an input or output ports are separated when a communications short occurs can also be activated from the control panel system diagnostics Mounts in standard 4 102 mm square electrical box adapter plate is available to mount in a 4 11 mm square electrical box LED flashes to indicate communications optional are available to view LED after installation TrueAlarm sensor base IDNet Isolators are also refer to data sheet S4098 0025 for details UL listed to Standard 864 fault isolation reduces time to fix wiring Built in control panel diagnostics assist in locating fault conditions the most common installation problem Class B or Class A wiring Communications are monitored from either port Class A wired SLCs can optimize operation by communications with devices outside of isolated wiring section Addressable IDNet Communications provide IDNet communications isolation to installation convenience and increase system Isolation is automatically activated when an short circuit is detected and isolation can also be manually from the control panel to assist with wiring problems Isolators power up in isolation mode and are to connect by the control panel If the output is acceptable the isolator will connect to the rest the circuit If the output wiring is shorted the isolator isolated Peripherals Addressable Communications Isolator Addressable IDNet Isolator approximately 1 2 size Continued Tracking The isolator reports back to the panel it is in isolation mode and the extent of shorted is reported back to the panel by identifying device that are not communicating Isolators are sequentially to low number addresses to expedite power up Faults During installation earth faults frequently Finding these faults normally requires extensive disconnection With the 4090 9116 Addressable Isolator earth faults on the IDNet communications can be quickly located to assist in their repair and to the system wiring to normal Selection Addressable IDNet Communications Adapter plate to fit 4 11 119 mm square box For semi flush box For surface box trim plate with viewing window mounting screws steel This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co the property of Tyco Fire Protection Products 10 2014 Multi Floor Isolator Example 1 Circuit Isolation The one line diagram on this shows a multiple floor example with Class B IDNet for each floor starting at an isolator A in the 4098 9793 Isolator Base is shown for as an alternate isolating device If floor wiring the isolator should experience a short circuit each is automatically separated from the next preventing short circuit from disabling the entire IDNet wiring Fault Isolation In the event of an earth fault floor can be individually isolated using built in panel diagnostics With individual floor control earth fault can be isolated to the floor level to narrow search area By adding more isolators the section to be isolated can be reduced allowing more to remain active floor floor floor floor base IDNET A IDNET A IDNET B IDNET B TIME RECORDER CO ISOLATOR INSTR 574 872 REV IDNET A IDNET A IDNET B IDNET B TIME RECORDER CO ISOLATOR INSTR 574 872 REV IDNET A IDNET A IDNET B IDNET B TIME RECORDER CO ISOLATOR INSTR 574 872 REV IDNet wire see wiring notes B riser IDNET A IDNET A IDNET B IDNET B TIME RECORDER CO ISOLATOR INSTR 574 872 REV Addressable IDNet Isolator Compatible TrueAlarm sensor base IDNet device type addressable ZAM IAM etc Notes Operation of the 4090 9116 Addressable IDNet Isolator requires connection a compatible 4007ES 4008 4010ES 4100ES or 4100U IDNet channel NOTE The 4100 3103 Panel Mounted Quad Isolator is compatible only with II Remote Isolators Maximum line resistance between the panel and an isolator and between two is 10 or 780 ft 238 m with 18 AWG wire This is a one line drawing showing only IDNet communications wiring Some IDNet devices require additional wiring for power Refer to specific for details 4100ES Series Control Panel for reference 10 2014 Multi Floor Isolator Example 2 A Wiring The illustration below is a modification Example 1 Each floor is wired as a Class A and a sensor mounted in a 4098 9793 Isolator has been added for reference This illustrates that additional isolators either the 4090 9116 or the Base there is a reduction in the number of devices in the event of a short circuit Assistance Communications from an 2 IDNet 2 2 or IDNet output provide individual circuit isolation and allow individual output control provide assistance in locating wiring faults When wiring Class A IDNet communications by IDNet or IDNet 1 outputs locate isolators the first and last devices in the loop close to the panel provide loop short circuit isolation operation as shown bases note 6 Wiring Example A riser with Isolators Class B taps IDNET A IDNET A IDNET B IDNET B TIME REC ORD ER CO 16 DRESSA BLE ISO LA TO R INSTR 574 872 R EV IDNET A IDNET A IDNET B IDNET B TIME RECO RDER C O ESSABLE ISOLATOR ST IN STR 574 872 REV IDNET A IDNET A IDNET B IDNET B TIME RECO RDER C O ESSABLE ISOLATOR ST IN STR 574 872 REV IDNET A IDNET A IDNET B IDNET B TIME REC ORD ER CO 16 DRESSA BLE ISO LA TO R INSTR 574 872 R EV IDNET A IDNET A IDNET B IDNET B TIME REC ORD ER CO 16 DRESSA BLE ISO LA TO R INSTR 574 872 R EV IDNET A IDNET A IDNET B IDNET B TIME RECORDER CO ISOLATOR INSTR 574 872 REV IDNET A IDNET A IDNET B IDNET B TIME RECORDER CO ISOLATOR INSTR 574 872 REV