Simplex 4090-9116 Addressable IDNet Isolator - Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings Addressable IDNet Isolator Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of carton for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times 4090 9116 IDNet Isolator is a line powered addressable device that short circuit protection on an IDNet channel When a short is detected the IDNet channel an IDNet Isolator connected between the 4100U Fire Control Panel FACP and the short shall automatically open the IDNet The 4100U FACP is able to command the Isolator to open or close the which enables the FACP to locate earths or shorts on the IDNet channel IDNet channel provides the communication link between Addressable Isolator and FACP and powers the circuit range of possible temperatures under which the 4090 9116 Addressable Isolator may function are between 0 C 32 F and 49 C 120 F 4090 9116 Addressable IDNet Isolator operates normally under non humidity conditions up to 93 with relative humidity at 32 C 90 F IDNet Isolator installation consists of the following Setting the Addressable IDNet Isolator address Making electrical connections to the Addressable IDNet Isolator Mechanically installing the Addressable IDNet Isolator Input Label Switch Re sealable Output Note The LED flashes approximately once every three seconds to indicate communications with the 4100U FACP 1 Addressable IDNet Isolator Assembly 2001 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice is a trademark of the Simplex Time Recorder Company B the Addressable Isolator Address The IDNet channel supports address codes 1 through 250 Addressable IDNet Isolator has a unique address The address of the IDNet Isolator is set via an eight position dip switch Figure 1 switch position 1 is the least significant bit LSB and position 8 is the most bit MSB Set the Addressable IDNet Isolator address using Figure as reference Use a small screwdriver or pen to set the switches The device for the Addressable IDNet Isolator should be written on the re sealable this information provides an aid in troubleshooting the system DIP switch in position is while DIP switch in position is IS SHOWN SET AT ADDRESS 7 ON OFF SWITCHES 5 THRU 8 1000 0100 1100 0010 1010 0110 1110 0001 1001 0101 1101 0011 1011 0111 1111 128 144 160 176 192 208 224 240 129 145 161 177 193 209 225 241 130 146 162 178 194 210 226 242 131 147 163 179 195 211 227 243 116 132 148 164 180 196 212 228 244 117 133 149 165 181 197 213 229 245 118 134 150 166 182 198 214 230 246 119 135 151 167 183 199 215 231 247 120 136 152 168 184 200 216 232 248 121 137 153 169 185 201 217 233 249 122 138 154 170 186 202 218 234 250 123 139 155 171 187 203 219 235 124 140 156 172 188 204 220 236 125 141 157 173 189 205 221 237 126 142 158 174 190 206 222 238 127 143 159 175 191 207 223 239 2 Addressable IDNet Isolator Address Chart the Addressable IDNet Isolator to the 4100 panel using the 4100 Fire PC Programmer Programming Manual 574 849 Configuration Electrical Connections the Addressable IDNet connections for the Addressable IDNet Isolator are illustrated in 3 Do not loop wire under terminals Break wire runs to supervision FACP NEXT STYLE 4 TO NEXT DEVICE IF USED STYLE 6 TO NEXT DEVICE or FACP R NEXT FACP IDNet and POWER WIRING METHOD IDNet and POWER RISER Maximum allowable run from FACP to farthest device not to exceed 2500 feet total wire including all T Taps from FACP is 10000 feet IDNet and are 18 AWG twisted pair shield recommended The Addressable IDNet Isolator counts as one unit load wiring is supervised and Power Limited 3 Addressable IDNet Isolator Connections R Installing the IDNet Isolator the Addressable IDNet Isolator into a grounded 4 inch U L Listed back not supplied using Figure 4 as a reference Mount the Addressable IDNet to the back box as follows Loosen the two screws on the square back box Mount the Addressable IDNet Isolator to the back box using the teardrop holes Secure the Addressable IDNet Isolator to the back box using the two 8 32 the mounting bracket screws Panhead Screw Supplied Listed Square 2 Inch Deep Box Supplied Supplied IDNet Isolator Flathead Screw Supplied Simplex offers semi flush and surface covers ordered separately with light pipe The cover s with light pipe allow viewing of the LED without taking the cover off Installation of the semi flush cover and 4090 9807 surface cover are detailed publication 4090 IDNet Semi Flush Surface Covers and IAM Installation Instruction 574 796 4 Addressable IDNet Isolator Back Box Installation B

Related Files