Simplex 4090-9117 Addressable Power Isolator for 4100ES, 4100U and 4010ES Series Fire Alarm Controls

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals 4090 9117 Addressable Power Isolator IDNet Communications Control port bi directional power isolator for use with 4007ES 4010ES 4100ES and 4100U fire alarm control panels Either port can serve as an input or output ports are separated when a power wiring short or a low voltage condition occurs can also be activated from the control panel system diagnostics For use with fire alarm control panel system power for up to 2 A 32 VDC communicate their location specific address status and accept control via IDNet Small size fits into 4 square electrical box and allows mounting where protection is required Visible LED flashes to indicate communications optional are available to view LED after installation fault isolation reduces time to fix wiring Built in control panel diagnostics can activate the power isolator assisting in locating earth conditions the most common installation wiring Class B or Class A power wiring Power is monitored from either port Two Isolators can be connected to produce Class A wiring that can optimize operation by connection with devices outside of the wiring section listed to Standard 864 Short Circuit Isolation Under normal conditions the Addressable Power Isolator provides continuity ports In the event of a short circuit or if requested the control panel the isolator opens a two pole switch isolating both power circuit conductors Isolators power up in isolation mode and are to connect by the control panel If the output is acceptable the isolator will connect to the rest the circuit If the output wiring is shorted the isolator isolated Tracking The isolator reports to the panel when it in isolation mode and the extent of shorted wiring is at the panel by identifying non communicating addresses Isolators are assigned sequentially to low addresses to expedite Signaling Line Circuit SLC Refer to Installation Instructions 574 873 for information Faults During system installation earth faults occur Finding these faults normally requires wiring disconnection With the Addressable Isolator earth faults on fire alarm system power can be more quickly located to expedite repair 2 3 4 5 6 7 8 2 3 4 5 6 7 8 CODE Addressable Power Isolator with IDNet Control shown approximately 1 2 size Selection Addressable Power Isolator For semi flush box For surface box trim plate with LED window includes screws galvanized Rating Power Reference Wiring Wiring A maximum 32 VDC maximum mA maximum 24 VDC system power communications 1 address one unit terminals for input and output wiring to 14 AWG 0.82 mm2 to 2.08 mm2 two up to 12 AWG 3.31 mm2 wire terminal to individual devices for wiring with 2081 9028 Circuit Protector to 2500 ft 762 m from fire alarm control to 10,000 ft 3048 m total wiring distance T Taps with Simplex 2081 9044 Protectors H x 4 1 8 W x 1 3 8 D mm x 105 mm x 35 mm to 120 F 0 to 49 C indoor operation to 90 RH at 90 F 32 C Range This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co the property of Tyco Fire Protection Products 11 2014 Power Isolator Multi Floor Example 1 Circuit Isolation The one line diagram on this shows a multiple floor example with Class B IDNet and conventional Class B power wiring floor wiring starts at an isolator If any floor beyond the isolator experiences a short circuit floor will be individually separated from the next the short circuit from disabling the entire run Fault Isolation In the event of an earth wiring each floor power wiring can be individually using control panel diagnostics This narrows the area by disconnecting the isolated wiring section can result in decreasing the time required to locate correct the earth fault sensor housing relay output floor device is a duct smoke housing When provided with detector it is designed to sample the air flow by it in the air duct to determine whether it contains unacceptable levels of smoke The of a duct smoke detector is highly dependent upon the design and operating conditions of the handling system in which it is installed variables such as smoke dilution and stratification over which the best designed systems have no control and proper placement and positioning of the duct smoke which is often compromised for practical reasons For the reasons stated above the effectiveness this duct smoke detector cannot be warranted or guaranteed Under no circumstances should this duct detector be used or regarded to be a substitute for the building Fire alarm and detection system to this device is attached as a secondary detection device NOT REMOVE THIS NOTICE local 24V IDNET PWR PWR TIME RECORDER CO ZAM CLASS B INSTR 574 183 CODE Adapter floor 2 3 4 5 6 7 8 2 3 4 5 6 7 8 CODE 2 3 4 5 6 7 8 2 3 4 5 6 7 8 CODE 2 3 4 5 6 7 8 2 3 4 5 6 7 8 CODE floor power VDC nominal sensor relay output communications wire see wiring notes B risers 2 3 4 5 6 7 8 2 3 4 5 6 7 8 CODE IDNet Power Isolator sensor with relay base Addressable Isolator see note 3 Notes This is a one line drawing showing only IDNet communications power wiring Operation of the 4090 9117 Addressable IDNet Power Isolator connection to a 4100ES 4010ES 4007ES or 4100U communications channel IDNet isolators are shown for typical reference but are not 4100ES Series Control Panel for reference 11 2014 Power Isolator Multi Floor Example 2 A Wiring The illustration below is a modification Example 1 Each floor wiring loop connects to the next in a Class A connection From the last device the returns to the panel providing a secondary path is monitored for loop integrity Class A power wiring available from a 4100ES 4010ES 4007ES or 4100U Control Panel programmed for this application using 4090 9117 Power Isolators mounted close nippled at panel Assistance It is recommended that for A wiring isolators be located as the first and last

Related Files