Simplex 4090-9118 4090-9118 Relay IAM (Individual Addressable Module) with T-Sense Input

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals 4090 9118 Relay IAM Individual Module with T Sense Input point operation provides a supervised input and a relay output in a single using only one address Typical applications are for damper motor control dual damper position feedback monitoring open closed For use with Simplex 4100ES 4100U or 4010ES Alarm Control Panels providing IDNet 4100U requires software revision 11 higher details operation is and provides supervised of normally open dry contacts Status conditions are Normal Open Circuit trouble Current Limited position input 1 and position input 2 Total wiring distance to supervised contacts is up to ft 152 m for indoor wiring applications Both data and power are provided by the IDNet link over a single wire pair Form C relay output is rated 2 A 30 VDC and A 120 VAC resistive ratings sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Screw terminals for wiring connections Optional covers are available to allow LED to be after installation Listed to Standard 864 Address Dual Point Module The 4090 9118 IAM with T Sense allows a Simplex 4100ES or 4010ES IDNet communication channel to two input contact closures with one point and an output relay with the other point both from a module requiring a single address Module is supplied from the IDNet communications eliminating the need for separate power wiring Device Description The input circuit and operation are controlled independently and may be separately Point association is determined at the panel At the host panel display the device address is as a single hardware location such as 1 1 individual points are considered and are underneath such as 1 1 1 and 1 1 2 Relay IAM with T Sense Input approximately 1 2 size Operation Input The 4090 9118 Relay IAM with has a supervised input that monitors for to an end of line resistor and can differentiate a short circuit contact closure and a current contact closure State Operation Normal is when all contacts are and there is continuity to the end of line resistor is when continuity does not exist to the end of line causing a Trouble condition Short indicates that contact has closed that is directly connected to the input and Current Limited indicates that a contact has beyond a series connected current limiting resistor operation allows differentiation between two contact types due to their wiring location and as a single IDNet addressable point to a fire alarm control panel Applications Package For smoke control applications this provides an efficient package for fan damper with position feedback The monitor point can be to two separate status indicator switches the host panel to track the fan damper status with to the requested fan control operation Applications The monitor and control points be applied for a variety of associated or independent Flexible programming abilities at the host can provide the association logic required for a variety of fire or utility operations This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 311 allowable values and or conditions concerning material presented in this document It is to re examination revision and possible cancellation Accepted for use City of New Department of Buildings MEA35 93E Additional listings may be applicable contact local Simplex product supplier for the latest status Listings and approvals under Time Recorder Co are the property of SimplexGrinnell LP Westminster IDNET12345678N C N O COMMON MON SIMPLEX TIME RECORDER CO 4090 9118RELAY IAM w T SENSEINST INSTR 574 874DATE CODE 1M LSBfirealarmresources com Resistor Harnesses ordered separately as required trim plate with LED viewing window includes mounting screws steel for current limited monitoring refer to diagram below Product Selection IAM with T Sense semi flush mounted box surface mounted box No Description k 1 2 W k 1 2 W T Sense Input Operating Modes Circuit Status Modes Position Monitoring Status Modes Status circuit Status Limited Status Limited Wiring Reference and Tamper Switch Monitoring Status Modes Status open discontinuity Status A closed B closed Status switch closed switch closed Display Panel Display Closed Open Display Alarm communications from host control panelT Sense Input4090 9118 Relay IAM with T Sense1.8 k 1 2 W Maximum distance to contacts is 500 ft 152 m input is for indoor wiring only IDNet Wiring Distances 1 Up to 2500 ft 762 m from host control panel 2 Up to 10,000 ft 3048 m total wiring distance including T taps NOTE Refer to Installation Instructions 574 874 for detailed installation information Current limited contactShorting contactTo next deviceN O ComN C OutputFor Fire Alarm applications locate loads within 3 ft 1 m of contactsPower Limited Contact Ratings 2 A 30 VDC resistive loads1 A 30 VDC inductive loadsNon Power Limited Contact Ratings 0.5 A 120 VAC resistive loads0.25 A 120 VAC inductive loads refer to specifications for additional information 4.7 k 2 WEnd of line resistorfirealarmresources com Mounting Information 102 mm square box 2 1 8 54 mm minimum depth RACO232 or equal supplied by others Double gang blank cover plate and mounting screws foruse when LED is not required to be externally viewed supplied by others 4090 9118 Relay IAMwith T SenseAddress setting underresealable label4090 9802 Trim plate for surface mounted box4090 9801 Trim plate for semi flush mounted boxOptional Trim Plates for Visible LEDMounting Reference Double Gang Blank Cover Plate4 9 16 116 mm 4 9 16 116 mm 4 5 16 109 mm Light pipe for LED viewing4 5 16 109 mm firealarmresources com Specifications Allocation IDNet one address one unit load power supplied from 4100ES 4100U 4010ES IDNet Type TRIAM Point Usage per Panel 2 1 for relay 1 for input Points Usage to 3 1 for relay 1 for input 1 for trouble for points mapped to the Fire Alarm Requirements to 500 ft 152 m total distance from Relay IAM open dry contacts indoor wiring applications only Supervision Resistors Connections required refer to Installation Instructions 574 874 for additional information wiring detail terminals for input and output wiring 18 to 14 AWG wire mm2 to 2.08 mm2 Contact Ratings C SPDT rated for switching A 30 VDC resistive A 30 VDC inductive A 120 VAC resistive A 120 VAC inductive listed fire alarm supply Provide circuit fusing and transient suppression as required per application DC inductive loads can typically be diode suppressed VAC loads may require RC networks or varistors depending on device type Refer to Installation Instructions 574 874 for information Wiring Distance Reference to 10,000 ft 3048 m total Class B wiring distance including T Taps to 2500 ft 762 m from the fire alarm control panel with 2081 9044 Overvoltage Protectors Range H x 4 1 8 W x 1 3 8 D 105 mm x 105 mm x 35 mm thermoplastic housing on metal mounting plate to 120 F 0 to 49 C indoor operation only to 90 RH at 90 F 32 C is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo and IDNet are trademarks of Tyco International Ltd and affiliates and are used unde

Related Files