Simplex 4090-9119 4090-9119 Relay IAM (Individual Addressable Module) with Unsupervised Input

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals 4090 9119 Relay IAM Individual Module with Unsupervised Input point operation provides an unsupervised and a relay output in a single package only one address Typical applications are for fan control with single status feedback monitoring For use with Simplex 4100ES 4100U or 4010ES Alarm Control Panels providing IDNet 4100U requires software 11 or higher details Input provides unsupervised monitoring of normally dry contacts Total wiring distance to supervised contacts is up to ft 152 m for indoor wiring applications Both data and power are provided by the IDNet link over a single wire pair Form C relay output is rated 2 A 30 VDC and A 120 VAC resistive ratings sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Screw terminals for wiring connections Optional covers are available to allow LED to be after installation Listed to Standard 864 Address Dual Point Module The 4090 9119 IAM allows a Simplex 4100ES 4100U or 4010ES communication channel to monitor an input contact closure with one point and an output relay with the other point both from a module requiring a single address Module is supplied from the IDNet communications eliminating the need for separate power wiring Device Description The input circuit and operation are controlled independently and may be separately Point association is determined at the panel At the host panel display the device address is as a single hardware location such as 1 1 individual points are considered and are underneath such as 1 1 1 and 1 1 2 Relay IAM with Unsupervised Input approximately 1 2 size Selection IAM with Unsupervised Input for 4100ES or 4010ES Systems semi flush box surface box trim plate with LED window includes screws galvanized Applications Package For smoke control applications this provides an efficient package for fan control with status feedback The monitor point provides from a single set of unsupervised contacts such a sail switch or pressure switch allowing the host to track the result of the requested relay control Applications The monitor and control points be applied for a variety of associated or independent Flexible programming abilities at the host can provide the association logic required for a variety of fire or utility operations This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of SimplexGrinnell LP IDNET12345678N C N O COMMON MON SIMPLEX TIME RECORDER CO 4090 9119RELAY IAM w UNSUPR FDBK INST INSTR 574 875DATE CODE 1M LSBfirealarmresources com Wiring Reference Specifications Allocation IDNet one address one unit load power supplied from IDNet communications Type FRIAM Point Usage per Panel 1 for relay Points Usage to 3 1 for relay 1 for input 1 for trouble for points mapped to the Fire Alarm Requirements to 500 ft 152 m total distance from Relay IAM open dry contacts Connections Contact Ratings C SPDT rated for switching A 30 VDC resistive A 30 VDC inductive A 120 VAC resistive A 120 VAC inductive indoor wiring applications only terminals for input and output wiring 18 to 14 AWG wire mm2 to 2.08 mm2 listed fire alarm supply Provide circuit fusing and transient suppression as required per application DC inductive loads can typically be diode suppressed VAC loads may require RC networks or varistors depending on device type Refer to Installation Instructions 574 875 for information Wiring Distance Reference to 10,000 ft 3048 m total Class B wiring distance including T Taps to 2500 ft 762 m from the fire alarm control panel with 2081 9044 Overvoltage Protectors Range H x 4 1 8 W x 1 3 8 D 105 mm x 105 mm x 35 mm thermoplastic housing on metal mounting plate to 120 F 0 to 49 C indoor operation only to 90 RH at 90 F 32 C communications from host control panelUnsupervised Input4090 9119 Relay IAM with Input Maximum distance to contacts is 500 ft 152 m input is for indoor wiring only IDNet Wiring Distances 1 Up to 2500 ft 762 m from host control panel 2 Up to 10,000 ft 3048 m total wiring distance including T taps NOTE Refer to Installation Instructions 574 875 for detailed installation information Normally open dry contactTo next deviceN O ComN C OutputFor Fire Alarm applications locate loads within 3 ft 1 m of contactsPower Limited Contact Ratings 2 A 30 VDC resistive loads1 A 30 VDC inductive loadsNon Power Limited Contact Ratings 0.5 A 120 VAC resistive loads0.25 A 120 VAC inductive loads refer to specifications for additional information firealarmresources com Mounting Information 102 mm square box 2 1 8 54 mm minimum depth RACO232 or equal supplied by others Double gang blank cover plate and mounting screws foruse when LED is not required to be externally viewed supplied by others 4090 9119 Relay IAM withunsupervised feedbackAddress setting underresealable label4090 9802 Trim plate for surface mounted box4090 9801 Trim plate for semi flush mounted boxOptional Trim Plates for Visible LEDMounting Reference Double Gang Blank Cover Plate4 9 16 116 mm 4 9 16 116 mm 4 5 16 109 mm Light pipe for LED viewing4 5 16 109 mm firealarmresources com is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo and IDNet are trademarks of Tyco International Ltd and affiliates and are used under license LP Westminster Westminster MA 01441 0001 USA 2011 Tyco All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice

Related Files