Simplex 4090-9119 Relay IAM (Individual Addressable Module) with Unsupervised Input for use with 4100ES, 4100U, or 4010ES IDNet Communications

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals 4090 9119 Relay IAM Individual Module with Unsupervised Input point operation provides an unsupervised and a relay output in a single package only one address Typical applications are for fan control with single status feedback monitoring For use with Simplex 4007ES 4010ES 4100ES or Fire Alarm Control Panels providing IDNet 4100U requires software 11 or higher details Input provides unsupervised monitoring of normally dry contacts Total wiring distance to supervised contacts is up to ft 152 m for indoor wiring applications Low power latching relay design allows IDNet to supply both data and module Relay is set to OFF on initial power up and upon loss IDNet communications Form C relay output is rated 2 A 30 VDC and A 120 VAC resistive ratings sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Screw terminals for wiring connections Optional covers are available to allow LED to be after installation Listed to Standard 864 Address Dual Point Module The 4090 9119 IAM allows a compatible Simplex fire alarm panel IDNet communications channel to monitor unsupervised input contact closure with one point and an output relay with the other point both from a module requiring a single address Module is supplied from the IDNet communications eliminating the need for separate power wiring Device Description The input circuit and operation are controlled independently and may be separately Point association is determined at the panel At the host panel display the device address is as a single hardware location such as 1 1 individual points are considered and are underneath such as 1 1 1 and 1 1 2 Relay IAM with Unsupervised Input approximately 1 2 size Selection Relay IAM with Unsupervised Input Adapter and Trim Plates Adapter plate to fit 4 11 119 mm square box For semi flush trim plate with LED box window includes screws galvanized For surface box Applications Package For smoke control applications this provides an efficient package for fan control with status feedback The monitor point provides from a single set of unsupervised contacts such a sail switch or pressure switch allowing the host to track the result of the requested relay control Applications The monitor and control points be applied for a variety of associated or independent Flexible programming abilities at the host can provide the association logic required for a variety of fire or utility operations This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 311 allowable values and or conditions concerning material presented in this document for use City of New York Department of Buildings MEA35 93E Additional may be applicable contact your local Simplex product supplier for the latest status and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 11 2014 Wiring Reference distance to contacts is 500 ft m input is for indoor wiring only open contact Input communications host control panel next device Wiring Distances Up to 2500 ft 762 m from host control panel Up to 10,000 ft 3048 m total wiring distance including T taps IAM Input Fire Alarm applications locate within 3 ft 1 m of contacts Limited Contact Ratings A 30 VDC resistive loads A 30 VDC inductive loads Limited Contact A 120 VAC resistive loads A 120 VAC inductive loads to specifications for additional Refer to Installation Instructions 574 875 for detailed installation information communications one address one unit load power supplied from IDNet communications Type FRIAM Point Usage per Panel 1 for relay Points Usage up to 3 1 for relay 1 for input 1 for trouble for points mapped to the Fire Alarm open dry contacts to 500 ft 152 m total distance from Relay IAM indoor wiring applications only terminals for input and output wiring 18 to 14 AWG wire mm2 to 2.08 mm2 A 30 VDC resistive A 30 VDC inductive A 120 VAC resistive A 120 VAC inductive listed fire alarm supply Contact Ratings C SPDT rated for switching Provide circuit fusing and transient suppression as required per application DC inductive loads can typically be diode suppressed VAC loads may require RC networks or varistors depending on device type Refer to Installation Instructions 574 875 for information Wiring Distance Reference to 2500 ft 762 m from the fire alarm control panel to 10,000 ft 3048 m total Class B wiring distance including T Taps with 2081 9044 Overvoltage Protectors Specifications Allocation Requirements Connections Range Instructions H x 4 1 8 W x 1 3 8 D 105 mm x 105 mm x 35 mm thermoplastic housing on metal mounting plate to 120 F 0 to 49 C indoor operation only to 90 RH at 90 F 32 C 11 2014 Mounting Information setting under label 102 mm square box 2 1 8 mm minimum depth RACO or equal supplied by others Relay IAM with feedback gang blank cover plate and mounting screws for when LED is not required to be externally viewed by others Reference Double Gang Blank Cover Plate mm mm pipe for LED viewing 116 mm Trim plate for mounted box 109 mm Trim plate for mounted box Trim Plates for Visible LED 11 2014 SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2014 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 11 2014

Related Files