Simplex 4090-9120 Six Point module with Four T-Sense Inputs and Two Relay Outputs for use with 4100ES, 4100U, 4010ES IDNet Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4090-9120-six-point-module-with-four-t-sense-inputs-and-two-relay-outputs-for-use-with-4100es-4100u-4010es-idnet-communications-4156390278.pdf |
---|---|
Type | |
Size | 642.57 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Peripherals 4090 9120 Six Point Module with T Sense Inputs and Two Relay Outputs point operation provides four supervised inputs and two relay outputs in a package using only one address For use with Simplex 4007ES 4010ES 4100ES or Fire Alarm Control Panels providing IDNet 4100U requires software revision 11 higher Typical applications include fan motor control centers fire pump motor running status low fuel warnings and for multiple dual damper feedback monitoring details Four inputs provide supervised monitoring normally open dry contacts Status conditions are Normal Open Circuit trouble Current Limited position input 1 and position input 2 Total wiring distance to supervised contacts is up to ft 152 m for indoor wiring applications Two relay outputs with Form C contacts rated A 30 VDC and 0.5 A 120 VAC resistive construction Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Optional covers are available to allow LED to be after installation Screw terminals for wiring connections Listed to Standard 864 Address Six Point Module The 4090 9120 Point Module allows a compatible Simplex fire alarm panel IDNet communications channel to monitor T sense input circuits and control two output relays a single compact module requiring a single address is supplied by a 24 VDC connection to a listed fire power supply Device Description The input circuits output relay operation are controlled independently may be disabled separately Point association is at the host panel At the host panel display device address is designated as a single hardware such as 1 1 Each of the six individual points as and are layered underneath such 1 1 1 1 1 2 1 1 3 POWER SERVICING PT I O 565 984 2 3 4 5 6 7 8 Six Point Module approximately 1 2 size Operation Input Each of the four input circuits for continuity to an end of line resistor and can between a short circuit contact closure and a limited contact closure State Operation Normal is when all contacts are and there is continuity to the end of line resistor is when continuity does not exist to the end of line causing a Trouble condition Short indicates that contact has closed that is directly connected to the input and Current Limited indicates that a contact has beyond a series connected current limiting resistor operation allows differentiation between two contact types due to their wiring location and as a single IDNet addressable point to the fire control panel Applications Package For smoke control applications this provides an efficient package for fan damper with position feedback Monitor points can be to two separate status indicator switches per allowing the host panel to track fan damper status respect to the requested fan control operation Applications The monitor and control points be applied for a variety of associated or independent Flexible programming abilities at the host can provide the association logic required for a variety of fire or utility operations This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this Accepted for use City of New York Department of Buildings MEA35 93E listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products 11 2014 Product Selection Point Module semi flush mounted box surface mounted box trim plate with LED viewing window includes mounting screws steel Resistor Harnesses ordered separately as required No Description k 1 2 W Standard end of line resistor harness for N O contact supervision k 1 2 W k 1 2 W for current limited monitoring applications refer to diagram below T Sense Input Operating Modes Circuit Status Modes Position Monitoring Status Modes Status circuit Status Limited Status Limited Status open discontinuity Status A closed B closed Status switch closed switch closed and Tamper Switch Monitoring Status Modes Wiring Reference k W distance to contacts is 500 ft m inputs are for indoor wiring only k 1 2 W Display Panel Display Closed Open Display Alarm limited 4 shown as a typical closure input k W resistor communications host control panel Fire Alarm applications locate within 3 ft 1 m of contacts Limited Contact Ratings A 30 VDC resistive loads A 30 VDC inductive loads Limited Contact A 120 VAC resistive loads A 120 VAC inductive loads to specifications for additional Point VDC Input 1 2 3 4 next device Wiring Distances Up to 2500 ft 762 m from host control panel Up to 10,000 ft 3048 m total wiring distance including T taps Refer to Installation Instructions 574 876 for detailed installation information 11 2014 Mounting Information indicating LED 102 mm square box 2 1 8 mm minimum depth RACO 232 equal supplied by others Six Point Module gang blank cover plate and mounting screws for when LED is not required to be externally viewed by others Reference Double Gang Blank Cover Plate mm mm pipe for LED viewing 116 mm 109 mm Trim plate for semi flush mounted box Trim plate for surface mounted box Trim Plates for Visible LED 11 2014 Specifications Power Allocation Requirements Supervision Resistors Connections communications one address 18 to 32 VDC nominal 24 VDC 30 mA maximum 24 VDC from listed fire alarm power supply Type MLPTIO Point Usage per Panel 6 1 per relay 1 per input Points Usage up to 7 1 per relay 1 per input 1 for trouble for points mapped to the Fire Alarm open dry contacts to 500 ft 152 m total distance from Six Point Module indoor wiring applications only required per T sense input refer to page 2 and to Installation Instructions for additional information and wiring detail terminals for input and output wiring 18 to 14 AWG wire mm2 to 2.08 mm2 A 30 VDC resistive A 30 VDC inductive A 120 VAC resistive A 120 VAC inductive listed fire alarm supply Contact Ratings C SPDT rated for switching Provide circuit fusing and transient suppression as required per application DC inductive loads can typically be diode suppressed VAC loads may require RC networks or varistors depending on device type Refer to Installation Instructions 574 876 for information Wiring Distance Refe