Simplex 4098-9401, 4098-9402, 4098-9403, & 4098-9404 Electronic Heat Detectors, direct connect models, 135° F (57° C) or 200° F (93° C), available with or without rate-of-rise operation (D) (B) (C)
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
CSFM Listed FM Approved NYC Acceptance Initiating Peripherals Electronic Heat Detectors for Direct Connect thermal detection for protection of listed to Standard 521 temperature operation is suitable for most Thermistor based design is inherently rate due to minimal thermal lag Available for 135 F 57 C or 200 F 93 C UL spacing distance is 60 ft with rate of rise temperature detection Dual thermistor rate of rise operation For use where anticipated ambient temperature are less than 6 F minute UL spacing distance is 70 ft encapsulated electronic design provides Easily tested self restoring operation with repeatable Alarm indicating LED located on detector Current limited alarm that is compatible with initiating device circuits IDCs connecting design Wiring attaches directly to detector terminals Detector mounts onto mechanical adapter plate Electronic Design Simplex electronic heat use a fast response thermistor based design to temperature sensing that quickly accurately and identifies when fixed temperatures are The fixed temperature sensing thermistor tracks the local ambient temperature This the time required to melt a lead pellet or heat a element as occurs in mechanical heat detector and provides the required heat detection for most detection is determined by comparing thermistor responses By combining accurate with proper physical placement this rate of rise detection design achieves a high of performance not normally available with detection Direct Connect Heat Detector Range Current Current Operation Range to 32 VDC filtered DC with maximum ripple A nominal to 100 mA maximum exact is determined by alarm limiting of connected FM requirements for between 15 and F min 8.33 and C min to 95 RH not intended outdoor applications diagram on page 2 Temperature Operating Range F Models F Models to 100 F 0 to 38 C to 150 F 0 to 68 C This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation for use City of New York Department of Buildings MEA35 93E This product not ULC listed as of document revision date Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Safety Products Westminster WARNING In most fires hazardous levels of smoke toxic gas can build up before a heat detection would initiate an alarm In cases where Life is a factor the use of smoke detection is highly Simplex electronic heat detectors are protected under U S Patent No 5,450,066 2 2008 Applications Reference detectors are used where property protection is desired where life safety protection is not required or is by other equipment Typical heat detector are satisfied by use of these fixed temperature detectors addition of rate of rise operation provides two forms of detection for use where temperature fluctuations are and are less than 6 F min 3.33 C min Where may fluctuate more quickly use fixed detection Fixed Temperature Guidelines F 57 C fixed temperature detectors are for temperatures that do not exceed 100 F 38 C F 93 C fixed temperature detectors are for temperatures that exceed 100 F 38 C but are than 150 F 66 C Indicating LED Operation heat detector LED turns ON continuously when in During normal conditions the LED is OFF Product Selection F C F C temperature with rate of rise temperature with rate of rise Maximum Spacing ft x 60 ft 18.3 m x 18.3 m ft x 70 ft 21.3 m x 21.3 m ft x 60 ft 18.3 m x 18.3 m ft x 70 ft 21.3 m x 21.3 m Maximum Spacing ft X 15 ft 4.5 m x 4.5 m ft X 30 ft 9.1 m x 9.1 m ft X 15 ft 4.5 m x 4.5 m ft X 30 ft 9.1 m x 9.1 m Installation Reference 102 mm octagonal box 38 mm deep minimum by others mount reference even with final or with up to 1 4 mm maximum recess mount reference 119 mm plate supplied mm detector assembly alarm indicator temperature sensing thermistor Refer to Installation Instructions 574 686 for additional information 2 2008 Applications Reference following table provides a reference for the rectangular area covered for detectors rated the given spacing For additional information consideration of ceiling height refer to 72 the National Fire Alarm Code Rectangular Area Dimensions For Single Detector Coverage ft Rated Spacing ft Rated Spacing ft Rated Spacing ft Rated Spacing m ft x 15 ft m x 4.5 m ft x 18.7 ft m x 5.7 m ft x 20.6 ft m x 6.2 m ft x 21.19 ft m x 6.4 m m ft x 30 ft m x 9.1 m ft x 34.2 ft m x 10.4 m ft x 37.4 ft m x 11.4 m ft x 39.7 ft m x 12.1 m ft x 41.2 ft m x 12.5 m ft x 42.1 ft m x 12.8 m ft x 42.4 ft m x 12.9 m 18.3 m ft x 60 ft m x 18.3 m ft x 64.6 ft m x 19.7 m ft x 68.5 ft m x 20.8 m ft x 72 ft m x 21.9 m ft x 74.8 ft m x 22.8 m ft x 77.3 ft m x 23.5 m ft x 79.3 ft m x 24.1 m ft x 81 ft m x 24.7 m ft x 82.4 ft m x 25.1 m ft x 83.5 ft m x 25.4 m ft x 84.2 ft m x 25.6 m ft x 84.7 ft m x 25.8 ft x 84.85 ft m x 25.8 m m ft x 70 ft m x 21.3 m ft x 74.6 ft m x 22.7 m ft x 78.7 ft m x 24 m ft x 82.3 ft m x 25 m ft x 85.4 ft m x 26 m ft x 88.1 ft m x 26.8 m ft x 90.5 ft m x 27.5 m ft x 92.6 ft m x 28.2 m ft x 94.3 ft m x 28.7 m ft x 95.7 ft m x 29.1 m ft x 96.9 ft m x 29.5 m ft x 97.8 ft m x 29.8 m ft x 98.4 ft m x 30 m ft x 98.8 ft m x 30.1 m ft x 99 ft m x 30.2 m 2 2008 is a registered trademark of Tyco International Services GMBH and is used under license Simplex and the Simplex logo are trademarks of Tyco International Ltd and its and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA 2008 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 2 2008