Simplex 4098-9601 TrueAlarm Photoelectric Smoke Detectors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4098-9601-truealarm-photoelectric-smoke-detectors-4250179368.pdf |
---|---|
Type | |
Size | 841.54 KB |
Downloads |
Text Preview
SSL Listed UL ULC Listed FM Approved MEA Approved smoke detector with on board sensitivity drift compensation Listed to AS1603.2 1997 listed to standard 268 indicator LED Provides detailed diagnostic information for normal and alarm conditions evaluation dirty detectors assisting with priorities chamber enclosure Louvered design enhances smoke capture by flow to chamber Entrance areas are minimally visible when ceiling operated functional test alarm and verifies performance general sensitivity status using detector sensitivity settings 4098 9601 Standard Sensitivity nominal 2.8 ft base options Bases for 2 wire or 4 wire operation Auxiliary alarm relay output remote alarm indicating LED ULC listed models are designated with a suffix such as 4098 9601C Detector 4098 9601 and compatible bases are for use City of York Department of Buildings MEA35 93E Simplex TrueAlarm smoke detector operation is protected by one or more of following U S Patents 5,155,468 5,173,683 5,543,777 5,400,014 5,552,763 DES 377,460 Smoke Detectors TrueAlarm Photoelectric Smoke Detectors Two Wire and Four Wire Bases TrueAlarm Photoelectric Mounted in Base TrueAlarm photoelectric detectors provide many the proven TrueAlarm analog sensing features for where detectors are connected to 2 wire or 4 wire initiating device circuits Each TrueAlarm detector has an on board that evaluates its photoelectric light chamber activity and makes an intelligent based on light obscuration history as to whether alarm condition is present detectors are packaged in a patented housing minimizes the visibility of the air intake louvers from normal viewing locations while maintaining a high smoke capture ability Bases are available remote alarm LED indicator connections and auxiliary outputs Current Current 2 Wire Current 4 Wire Relay Ratings Velocity Range Approval Listing Temp Range Range to 32 VDC from Fire Alarm Control IDC 24 VDC to 86 mA maximum exact current is by alarm current limiting of IDC mA typical 24 VDC to page 2 under Product Selection ft min 0 610 m min to 8,000 ft 2438 m C to 50 C to 95 RH from 0 C to 50 C White 7 8 Dia x 1 7 8 H mounted in base mm x 48 mm refer to p 3 for detail 1999 Simplex Time Recorder Co All rights reserved 8 00 Smoke Detector Features Data Evaluation Conventional smoke will typically drift toward being too sensitive to the accumulation of dust and dirt With TrueAlarm detection data from the photoelectric chamber is and analyzed at the detector to provide a shifting reference point Compensation The data evaluation and its reference point provide a software filtering that compensates for environmental factors dust etc and component aging establishing an accurate for evaluating new activity With this filtering resulting drift compensation provides a significant in the probability of false or nuisance alarms by shifts in sensitivity either up or down LED Output Detailed service information provided by pulses that are continuously and invisibly into the detector LED status indicator A Smoke Detector Sensitivity Reader service tool this information without requiring direct contact and initiating an alarm Diagnostic information detailed detector identification and the detector compensation level to assist maintenance by an indication of its dirt accumulation status Test Information Status information is also by performing the magnetic test and observing detector LED pulses The LED will normally go into alarm with the magnetic test If there is an condition the LED pulses first to indicate the and then goes into alarm See page 3 Reference Locations Locations should be determined after careful consideration of the physical layout and of the area to be protected Refer to NFPA 72 National Fire Alarm Code further detailed installation information refer to publication 574 709 4098 Detectors Sensors Bases Application Manual Selection The 4098 9601 standard detector is recommended for most applications a special application for a reduced sensitivity is required the 4098 9605 should be considered Simplex for assistance in determining the proper Product Selection Detectors Bases Photoelectric Detector Sensitivity standard with detector bases 4098 9682 and 4098 9683 Base with connections for Remote LED Indicator IDC and LED connections are screw terminals for in out 18 to 14 AWG Base with Auxiliary Alarm Relay and connections for Remote Alarm Indicator Base with Auxiliary Alarm Relay connections for Remote LED Indicator Must be connected as the only device the IDC to ensure relay operation Accessories Adapter Plate Remote LED Indicator Encapsulated 24 VDC End of Line Relay Plate Mounted 24 VDC End of Line Relay Ratings Single Form For Suppressed Loads Power limited 3 A 28 VDC Non power limited 3 A 120 VAC Connections In Out where required Relay contacts and IDC wiring color coded 18 AWG leads LED wiring screw terminals for 18 to 14 AWG Ratings Dual Form For Suppressed Loads Power limited 1 A 28 VDC Non power limited 1 2 A 120 VAC Connections In Out where required Relay contacts and IDC color coded 18 AWG leads IDC and LED wiring screw terminals for 18 to 14 AWG Required for mounting to 4 square box fits 4 octagonal box May be used when retrofitting existing bases Compatible with 4098 9788 9682 9683 detector bases Mounted on single gang stainless steel plate Required for 4 wire circuits using 4098 9682 base one per select mounting type as required Time Recorder Co 8 00 Visible LED Status Indications Indication every 4 seconds On is Normal power is applied is in Alarm Indication By Response to Magnetic Test turns ON quickly 6 times in seconds then turns ON is initiated slowly 4 times in 8 then turns ON sensitivity is compensation range sensitive out of compensation range sensitive out of compensation range or other is required not initiate Alarm Detector is malfunctioning is required Includes encoded diagnostic information within the LED flash Refer to page 2 for description Testing requires placing a magnet at the designated location on the detector cover for 4 seconds Refer to application manual for further test and maintenance information Dimensions and Reference Information mm 3 8 162 mm Optional Adapter Plate for 4 square box 7 8 124 mm 7 8 mm Height mm Status Indicator 9605 Dimensions Mounted on Base 4098 9830 Remote LED Indicator not to scale Time Recorder Co 8 00 Mounting Information boxes are supplied by others Box Requirements Relay base 4098 9788 octagonal or 4 square 1 1 2 deep single gang 2 deep Relay bases 4098 9682 and 4098 9683 octagonal 2 1 8 deep with 1 1 2 extension ring Optional Adapter Plate for 4 square box and 4098 9683 a relay module that in base electrical box Detector Bases 9683 9788 9605 Smoke