Simplex 4098-9687, 4098-9842 TrueAlarm Smoke Detector Duct Detector Housing and TrueAlarm Photoelectric Detector for Stand-Alone Operator

File Preview
File Preview
Click below to download for free

Text Preview

CSFM Listed NYC Acceptance Smoke Detectors Duct Detector Housings with TrueAlarm Photoelectric for Stand Alone Operation stand alone operation air duct detector with clear cover to monitor for the of smoke factory installed TrueAlarm smoke detector and features On board TrueAlarm sensitivity drift compensation dirt accumulation tracking Multi function status LED indicator on detector Magnetic test that initiates an alarm and provides diagnostic information Clear cover allows visual inspection Test ports provide functional smoke testing access cover in place Input power of 120 VAC 24 VAC or 24 VDC UL listed to Standard 268A relay output features Fail safe operation that is normally energized and upon alarm loss of power or detector Contacts are Form C rated 5 A 120 VAC or VDC resistive requires Control Station 4098 9842 Provides power on LED alarm LED local tone alert local tone alert silence and keyed test reset Control station is ordered separately to rectangular ducts or round ducts Minimum size is 8 203 mm square or 18 mm diameter operated functional test Initiates alarm and displays dirt accumulation status the detector status LED Assists with maintenance priorities by categorizing status and identifying dirty detectors tubes ordered separately Available in multiple lengths to match duct size Installed and serviced with housing in place Please note that smoke detection in air ducts is intended to provide of the presence of smoke in the duct It is not intended and will not replace smoke detection requirements for open or other non duct applications This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation This product not ULC listed or FM approved as of document revision date Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection device is a duct smoke housing When provided with detector it is designed to sample the air flow by it in the air duct to determine whether it contains unacceptable levels of smoke The of a duct smoke detector is highly dependent upon the design and operating conditions of the handling system in which it is installed variables such as smoke dilution and stratification over which the best designed systems have no control and proper placement and positioning of the duct smoke which is often compromised for practical reasons For the reasons stated above the effectiveness this duct smoke detector cannot be warranted or guaranteed Under no circumstances should this duct detector be used or regarded to be a substitute for the building Fire alarm and detection system to this device is attached as a secondary detection device NOT REMOVE THIS NOTICE Stand Alone Duct Detector Front View Control Station Operation Model 4098 9687 duct detector housings with smoke detector for applications that operate independent of a fire control panel They provide a TrueAlarm smoke for monitoring air conditioning or ventilating Sampling tubes are installed into the duct allowing to be directed to the smoke detector mounted in the Control Station 4098 9842 provides a red LED a green power on LED a piezoelectric a tone alert silence switch and a key switch for normal operating mode or to initiate a test or operation This control station is required Operation If an alarm is detected the relay contacts transfer the control station sounds and the alarm LED illuminates the Silence switch will silence the tone alert the source of the alarm is located and resolved the key switch to Test Reset will reset the Relay Operation The output relay contacts held energized during normal operation Upon loss of or removal of the detector the contacts will 11 2012 Duct Detector Selection Chart Stand alone operation duct detector with internal output relay power is 120 VAC 24 VAC or 24 VDC 4098 9842 Test Station separately Station required ordered separately Station with power on green LED red alarm LED silence switch and key switch for test reset on steel plate double gang box H x 4 W x 2 D mm x 102 mm x 51 mm Stand alone duct detector housing includes an internally mounted model 4098 9601 TrueAlarm photoelectric detector and an exhaust A correctly sized sampling tube ordered per application is required refer to chart below Sampling Tube Selection Chart Ordered Separately Per Duct Width Select One Duct Width 305 mm to 23 330 mm to 584 mm to 46 610 mm to 1168 mm to 71 1168 mm to 1803 mm to 95 1803 mm to 2413 mm Required Cut Length 12.7 mm longer than duct width 12.7 mm longer than duct width in 76 mm longer than duct width in 76 mm longer than duct width in 76 mm longer than duct width 4098 9842 Control Station Indicator Reference Status LED LED missing detector head power fail On Off Relay energized de energized TrueAlarm Detector Status LED Indications approximately every 4 seconds Indication On LED Response to Magnetic Test Indication turns ON pulses quickly times in 3 seconds turns ON pulses slowly times in 8 seconds turns ON By is initiated is initiated is initiated not initiate Alarm sensitivity is within range sensitive out of normal range sensitive out of normal range is malfunctioning or other is required is required Testing requires placing a magnet at the designated location on the duct housing cover for 4 seconds and referring to the response from red LED status indicator on the detector Refer to Installation Instructions 574 777 for further test and maintenance information 11 2012 Stand Alone Duct Detector Housing Detail Reference Refer to Installation Instructions 574 777 for additional detail and maintenance information test area 289 mm tube access hole by others LED mm tube hole Smoke detector in base supplied baffle built in fastening screws 4 cover detector area VDC VAC and control terminals device is a duct smoke housing When provided with detector it is designed to sample the air flow by it in the air duct to determine whether it contains unacceptable levels of smoke The of a duct smoke detector is highly dependent upon the design and operating conditions of air handling system in which it is installed variables such as smoke dilution and stratification over even the best designed systems have no control and proper placement and positioning of the duct detector which is often compromised for practical reasons For the reasons stated above the of this duct smoke detector cannot be warranted or guaranteed Under no circumstances this duct smoke detector be used or regarded to be a substitute for the building Fire alarm and system to which this device is attached as a secondary detection device plate with dual holes 3 4 19 mm conduit plug for unused hole NOT REMOVE THIS NOTICE View VAC input terminals output terminals

Related Files