Simplex 4098-9794 TrueAlarm Photoelectric, Ionization, and Heat Sensors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4098-9794-truealarm-photoelectric-ionization-and-heat-sensors-4293170586.pdf |
---|---|
Type | |
Size | 811.24 KB |
Downloads |
Text Preview
ULC Listed FM CSFM MEA NYC Approved Analog Sensing Sounder Base 4098 9794 for use with Photoelectric Ionization and Heat Sensors Modular TrueAlarm sensor base with built in alarm sounder Piezoelectric sounder provides high output 88 dBA low current requirements 20 mA For use with interchangeable TrueAlarm sensors heat or ionization ordered separately operation can be Powered from 24 VDC or from a compatible Appliance Circuit NAC Synchronized via communications or by the NAC NAC powered Manually activated from the control panel analog sensing operation Analog sensor information is digitally communicated the control panel via MAPNET II or IDNet communications Sensor information is processed by the control panel determine sensor status use with Simplex control panels model 4020 4100 4120 and Universal and architecturally styled enclosure ceiling or wall mounting Sound louvers exit both front and side for high output Smoke sensor louver design directs air flow to enhancing smoke capture Built in magnetic test feature accessories Remote alarm LED indicator on single gang plate Alarm LED tracking relay listing status Sensor and sounder operation is listed to UL 268 Sounder operation is also listed to UL Standard 464 an audible notification appliance This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Refer to page 4 for ULC status Additional listings may be applicable contact your local Simplex product for the latest status Total quantity of sounder bases available for coding on the same communications channel may with panel application and availability of NAC power Refer to specific control panel TrueAlarm analog sensors and MAPNET and IDNet communications are protected by one or of the following U S Patents 5,155,468 5,173,683 5,543,777 5,400,014 5,552,765 4,796,025 DES 377,460 Photoelectric Sensor Mounted in Base 4098 9794 Analog Sensing Description bases combine an audible notification appliance a TrueAlarm analog sensor to provide Communication of Analog Sensing provide an analog measurement that is digitally to the control panel where it is analyzed an average value is determined and stored An alarm other abnormal condition is determined by comparing sensor present value against its average value Data Evaluation Monitoring each sensor value provides a software filtering averaging that compensates for environmental factors dust etc and component aging providing an accurate for evaluating new activity The result is a reduction in the probability of false or alarms caused by shifts in sensitivity either up down Panel Selection Peak activity per sensor is to assist in evaluating specific locations The alarm point for each TrueAlarm sensor is determined at the panel selectable as more or less sensitive as the application requires Selection Alarm set points can be for timed automatic sensitivity selection as more sensitive at night less sensitive during Control panel programming can also provide operation per sensor For example a 0.2 may cause a warning to prompt investigation while a level may initiate an alarm Alarm and Trouble LED Indication The panel determines when individual sensors need Dirty sensors or other sensor trouble will be annunciated at the control panel and that base LED will light steadily In an alarm the alarmed sensor LED will light steadily operation is controlled by the panel During a alarm a sensor LED steady on to indicate a may return to pulsing to conserve communications 12 01 Additional Sounder Base Features Base mounted address selection allows the address remain with its programmed location when the sensor removed for service or type change Access is from the under the removable sensor sensor type identification provides sensitivity when substituting sensor types sensor types can be easily interchanged to meet location requirements This feature also allows sensor substitution during building When conditions are temporarily dusty of covering the smoke sensors causing them to be heat sensors may be installed without the control panel red LED indicates power on by pulsing or or trouble when steady on The exact status is at the fire alarm control panel alarm control panel operation features sensitivity selection for each sensor Sensitivity monitoring that satisfies NFPA 72 testing requirements Peak value logging allowing accurate analysis for selection Automatic once per minute individual sensor check verifies sensor integrity Automatic environmental compensation Display of sensitivity directly in percent per foot Multi stage alarm operation Ability to display and print detailed sensor information plain English language Accessories LED Annunciation Relay activates when LED is on steady indicating a local alarm or trouble are DPDT rated 2 A 30 VDC 1 2 A VAC for transient suppressed loads requires external VDC coil power Remote red LED Alarm Indicator mounts on single gang box to provide status indications where the location may not be readily visible Mounting Reference Box Requirements boxes are by others relay 4 octagonal or 4 square 1 1 2 deep single gang deep relay 4 octagonal or 4 square 1 1 2 deep with 1 1 2 ring 102 mm Square Box mount reference 102 mm Octagonal Box 38 mm box depth Single gang plate RACO 787 or equal is when using 4 box by others mount reference mount even with final or with up to 1 4 6.4 mm maximum recess 4098 9822 Relay in base electrical box requires additional see notes below size X 1 1 2 X 1 mm X 38 mm X 25.4 mm 3.75 cubic inches Adapter Plate required for mounting surface mounted boxes mounts inverted 164 mm mm status output louvers from front to side sensor shown for reference Review actual wire size wire count box type and whether 4098 9822 relay is used before determining box size Mounting to flush mounted box also fits single gang handy box 2 1 8 51 mm deep if wiring allows Not applicable if 4098 9822 relay is used For surface mounted boxes use 4 square box with single gang adapter plate RACO No 787 or equal by others or 4 octagonal box both require 4098 9832 Adapter Plate When 4098 9822 relay is used mount relay in electrical box and use 1 1 2 extension ring by others on 4 square or octagonal box of 1 1 2 or 2 1 8 depth as required Refer to Installation Instructions 574 707 for additional information Remote LED Alarm Indicator 12 01 TrueAlarm Analog Sensor Features against rear air flow entry are EMI RFI shielded sensors Selectable rate compensated fixed temperature sensing or without rate of rise operation Listed to UL Standard 521 for 60 ft 18.3 m spacing 135 F 57.2 C alarm and 40 ft 12.2 m spacing 155 F 68 C alarm sensors Photoelectric or ionization technology sensing 360 smoke entry for optimum response Built in insect screens Heat Sensor heat sensors are self restoring and provide rate fixed temperature sensing selectable with without rate of rise temperature sensing Due to its thermal mass the sensor accurately and quickly the local temper