Simplex 4098-9846 TrueAlarm Sensor Vandal Guard Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4098-9846-truealarm-sensor-vandal-guard-installation-instructions-9875041326.pdf |
---|---|
Type | |
Size | 671.68 KB |
Downloads |
Text Preview
Cautions and Information TrueAlarm Vandal Guard Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon your Simplex product inspect the contents of the carton for shipping damage If is apparent immediately file a claim with the carrier and notify Simplex This product is designed to protect a smoke sensor from vandalism It not designed to protect people from intentionally causing harm to Please use caution when installing this device in detention hospitals or other residential or highly trafficked locations HAZARD Disconnect electrical power when making any internal adjustments or Servicing should be performed by qualified Simplex representatives NFPA Section 2 1.3.1 1999 Edition subject to mechanical damage an initiating shall be protected A mechanical guard used to protect a smoke or heat detector shall be for use with the detector being used presence of debris on the sensor vandal guard will significantly restrict airflow into the sensor is recommended that increased visual maintenance be performed to ensure proper operation publication shows how to install the 4098 9846 TrueAlarm Sensor Vandal Guard The sensor is a device that is mounted on a wall or ceiling to provide protection for a 4098 9714 Smoke Use only a 4098 9714 Sensor Refer to 2120 Job Configuration Report or Custom Control Equation Listing in 4010 4020 or 4100 Programmer Report to verify the sensitivity range is 0.5 to 1.5 per foot obscuration steps 1 through 6 and refer to Figures 1 through 3 to install the sensor guard Seal the electrical box using 3M Weatherban 606 or equivalent Use the appropriate template below to drill holes for appropriate anchoring per local codes Use Figure 2 if you are flush mounting with the mounting frame Use Figure 3 if you are surface mounting with the 4098 9847 Extension Box the sensor and base The installed sensor base must be a 4098 9789 4098 9791 4098 9792 or Refer to 4098 Smoke Heat Sensor Bases Installation Instructions 574 707 when sensor bases 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice is a registered trademark of Simplex Time Recorder Co is a registered trademark of Minnesota Mining and Manufacturing on next page A Sensor Guard Installation Instructions Continued Flush Mount Electrical Box the sensor guard mounting frame to the wall or ceiling using 1 4 inch minimum hex head bolts with lead expansion shields or toggle bolts not supplied Avoid shields Mount Electrical Box the 4098 9847 Extension Box to the wall or ceiling using 1 4 inch minimum hex head bolts with lead expansion shields or toggle bolts not supplied Avoid shields Secure the sensor guard mounting frame to the extension box using 1 4 inch hex head bolts not supplied Place the sensor guard cover in the mounting frame Secure the cover to the frame using four 10 32 x 1 2 inch long button head hex with center screws supplied Use the 4098 9823 5 32 Inch Tamperproof Hex Key 553 692 not to install the screws DO NOT paint the sensor guard 1 inch Extension Must be used for surface electrical box 10 32 x 1 2 Inch Head Drilled Drivers and Spanner Insert Supplied Box or Surface Supplied Sensor Warning below with 4098 9791 or 4098 9793 Base Guard Frame 1 4 inch Diameter Screws Supplied Guard Cover 1 Installing the Sensor Guard with a 4098 9789 9791 9792 or 9793 Sensor Base on next page Sensor Guard Installation Instructions Continued and recommends routine cleaning of the smoke sensor and guard so that dust and other matter not accumulate Refer to the 4098 Detectors Sensors and Bases Application Manual for details The strength of final installation requires heavy solid anchoring flush mounted electrical box must be installed even to the or be recessed 1 4 inch maximum If the electrical box is mounted the 4098 9847 Extension Box must be used the figures on the next pages as templates when you are mounting the sensor guard Use Figure 2 for flush mount applications Use Figure 3 for surface mount applications Do not photocopy this figure Use the original figure as a template 2 Sensor Guard Mounting Frame Template Flush Mounting Do not photocopy this figure Use the original figure as a template 3 4098 9847 Extension Box Mounting Template Surface Mounting A