Simplex 4098 Smoke-Heat Sensor Base Rev G
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4098-smoke-heat-sensor-base-rev-g-0916852743.pdf |
---|---|
Type | |
Size | 635.42 KB |
Downloads |
Text Preview
Note 4098 9791 4098 9794 4098 9795 and 4098 9796 are not compatible with the 2120 CDT BASES FLUSH MOUNTED TO BE FLUSH OR RECESSED 1 4 MAX 9791 9792 9796 ALL DETECTOR BASES FLUSH MOUNTED TO BE FLUSH MOUNTED OR RECESSED 1 4 MAX AND 4098 9795 ONLY MOUNTED WITH ADAPTER BRACKET TO FLUSH OR RECESSED 1 4 MAX GANG 2 1 8 DEEP BOX SUPPLIED 10.16cm x 1 1 2 DEEP BOX NOT SUPPLIED 10.16cm x 1 1 2 DEEP BOX SUPPLIED Smoke Heat Sensor Bases Instructions TrueAlarm cid 226 Smoke Heat Sensor and Sounder Bases are connected to a 2120 Multiplex Communication Transponder CDT 4010 4020 4100 or 4120 Fire Alarm Panel by a single wire pair MAPNET or IDNet cid 212 The 4098 9789 9791 9792 9794 and 9796 sensor bases and their sensors obtain both and data over MAPNET II or IDNet wiring Additionally the 4098 9791 sensor base requires power for relay operation The 4098 9794 sensor base with sounder and 4098 9795 Multi Sensor base require 24VDC or Notification Appliance Circuit NAC power document covers only the information necessary to mount and wire these sensor base configurations installing these devices make a survey of the area to be covered in accordance with information in NFPA 72 Chapter 5 For specific applications refer to Simplex publication Common Code for Fire Alarm Systems Publication No FA2 91 010 For additional information refer to 72 and the NEMA Guide for Proper Use of System Smoke Detectors to the 4098 Detectors Sensors and Bases Application Manual 574 709 was shipped with the fire alarm system for compatibility and data address settings maintenance and correct application of Smoke Heat Sensor Bases the bases described in this instruction in accordance with applicable standards local codes and the authorities having jurisdiction Failure to these instructions may result in failure of the sensor to initiate an alarm Simplex is not responsible for sensors that have been improperly tested or maintained smoke sensors come with dust covers to protect them from contamination completion of building construction Sensors will not operate with dust in place PLATE KIT FOR 4 SQUARE SURFACE MOUNTED BOX NOTE 4 6 32 SCREW WASHER SUPPLIED 8 32 x 1 1 4 MACHINE TO 4 6 in lbs REQUIRED NOTES 1 AND 2 ATTACHMENT 787 BRACKET EQUIVALENT SUPPLIED 8 32 x 1 1 4 MACHINE UNTIL SNUG in lbs 8 x 1 THREAD FORMING SCREW TO 4 6 in lbs x 1 1 4 SCREW TO 4 6 in lbs 4098 smoke heat sensor bases mount to a 4 inch square single gang or 4 inch octagonal electrical box the sensor base using Figure 1 a reference bases with Relay Modules 2098 9737 and 4098 9822 require an 1 extension ring not mounted to the 4 inch square or octagonal electrical box relay module s cannot be used single gang electrical box installations to meet the space requirement of the relay cube and its The Relay Module 4098 9822 must be installed in the electrical box directly behind the base Break off plastic lock tab to engage locking mechanism To lock sensor into base turn unit until the locking tab clicks into place To unlock sensor the blade of a screwdriver into this slot and then pull down on handle This action allows the sensor to be turned and removed Refer to the 4098 Detectors Sensors and Bases Application Manual 574 709 for detailed information on compatible Sensor s and DIP Switch Settings Use the slotted hole indicated for the first screw when mounting the sensor base Use Adapter Plate Kit 4098 9832 when mounting the 4098 9794 and 4098 9795 to a surface mounted 4 inch square or octagonal box Adapter plate be installed with textured side towards the electrical box for this installation only 1 Typical Base Mounting or following an eight Digit Product ID number denotes ULC listed product following an eight digit Product ID number denotes Global product The 2nd suffix identifies market country models with this suffix are not UL Listed II cid 226 Communication Net is protected by U S Patent No 4,796 025 is protected by U S Patent No 5,155,468 is a trademark of Simplex Time Recorder Company 1999 Simplex Time Recorder Co Gardner MA 01441 0001 USA 1999 Simplex International Time Equipment Co Ltd Mississauga Ontario L4V 1H3 Canada specifications and other information shown were current as of publication and are subject to change without notice G 2 illustrates the wiring connections for the different smoke heat sensor base configurations All screw terminals accept 14 to 18 gauge AWG solid or stranded wire torque should not exceed 12 inch pounds Connect wiring to terminals as illustrated in Figure 2 not loop wire under terminals Break wire runs to provide supervision OTHER 24V DEVICES NEXT OR NAC LED 4098 9822 IF USED NOTE 1 NOTES 8 10 5 NOTE 8 9795 BASE BASE 9796 BASE NOTE 3 NOTE 3 NOTE 3 N C N O B NOTE 4 N C N O CONTACT A NOTE 4 MAPNET II IDNet MAPNET II IDNet 6 RELAY 9 N C N O A NOTE 7 6 9 BASE NOTE 8 N C N O B NOTE 7 NOTE 3 MAPNET II IDNet MAPNET II IDNet OTHER II DEVICES NOTE 2 Maximum quantity of devices per circuit is 127 for 4020 4100 or 4120 128 for the 2120 CDT panel and 250 for the 4010 panel Maximum quantity of 4098 9795 and 4098 9796 Multi Sensor bases is 63 with 4020 4100 and 4120 and 124 for the 4010 panel LED and relay wires are not supervised 4098 9795 output is coded Temporal code etc via MAPNET II IDNet control see note 10 shield is used twist shield wires together and cap with wire nut Shield should be insulated from electrical box A or B Dry Form C each rated 2 amperes at 24VDC 0.5 amperes at 110VAC resistive to 32VDC 008 amperes typical 013 amperes max not use remote LED if the 4098 9822 relay module is used A or B Dry Form C Each rated at 3 amperes at 28VDC 115VAC resistive 4098 9794 4098 9795 and 4098 9796 are not compatible with 2120 CDT Maximum wire length between 4098 9791 sensor base and 2098 9737 relay module is 100 feet Maximum quantity of sensors with 4098 9794 or 4098 9795 sounder bases limited to 43 if output is coded Temporal code etc via MAPNET II IDNet control If coding is performed via 24VDC or NAC circuit see note 2 2 4098 Smoke Heat Sensor Base Connections G