Simplex 4099-9001, 4099-9002, 4099-9003, 4099-9001CB, 4099-9001CF, 4099-9020, 4099-9805 IDNet or MAPNET II Addressable Manual Stations and Accessories; Includes NO GRIP Handle models (B)
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Peripherals or MAPNET II Communicating Devices Manual Stations addressable manual fire alarm with Power and data supplied via IDNet or MAPNET II communications using a single wire pair Operation that complies with ADA requirements The NO GRIP Single Action Station and Retrofit Kit available with a more easily operated pull lever for where anticipated users may find the station lever difficult to activate Pull lever that protrudes when alarmed Break rod supplied use is optional Models are available with single or double action or push operation UL listed to Standard 38 with the following Simplex control Model Series 4100ES 4010ES 4008 4010 4100U 4100 and 4120 fire alarm control panels with either IDNet or MAPNET II Model Series 2120 Communicating Device CDTs equipped with MAPNET II construction Electronics module enclosure minimizes dust Allows mounting in standard electrical boxes Screw terminals for wiring connections resistant reset key lock keyed same as fire alarm cabinets mounting options Surface or semi flush with standard boxes or matching boxes Flush mount adapter kit Adapters are available for retrofitting to commonly existing boxes Simplex addressable manual station combines the Simplex manual station housing with a compact module that is easily installed to satisfy applications Its integral individual module IAM constantly monitors status and changes to the connected control panel via or MAPNET II communications wiring Refer to page 2 for specific model listings This product has been approved by the State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health Safety Code See CSFM Listing 7150 0026 224 for allowable values and or conditions material presented in this document It is subject to re examination revision possible cancellation Accepted for use City of New York Department of Buildings Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products action GRIP action GRIP kit GLASS 2099 9828 kit of the 4099 9001 single action manual station a firm downward pull to activate the alarm switch the action breaks an internal plastic break rod below the pull lever use is optional The use of a can be a deterrent to vandalism without with the minimum pull requirements needed for activation The pull lever latches into the alarm and remains extended out of the housing to provide visible indication Action NO GRIP Station 4099 9020 For such as California Building Code Title 24 requires and operating mechanisms shall operable with one hand and shall not require tight pinching or twisting of the wrist the model station provides a more easily operated pull compared to standard stations Retrofit of existing is available using the 4099 9805 Retrofit kit Action Stations Breakglass require the to strike the front mounted hammer to break the and expose the recessed pull lever The pull lever then as a single action station Action Stations Push Type require that a loaded interference plate marked PUSH be pushed to access the pull lever of the single action station reset requires the use of a key to reset the manual lever and deactivate the alarm switch If the break is used it must be replaced testing is performed by physical activation of the lever Electrical testing can be also performed by the station housing to activate the alarm switch 5 2012 Addressable Manual Station Product Selection Manual Stations Red Housing with White Letters and White Pull Lever Lever action English Single action Bilingual English and French Single action French Double action Breakglass operation English Double action Push operation English action NO GRIP operation English mount steel box red ALARM FIRE FEU DOWN UL ULC FM CSFM MEA PULL FM ALARM DOWN UL ULC FM CSFM MEA ALARM DOWN UL ULC FM CSFM to page 3 for dimensions trim plate for double gang switch box red trim plate for Wiremold box V5744 2 red mount adapter kit black mount adapter kit beige Cast aluminum surface mount box red Replacement breakglass Replacement break rod Retrofit Kit for field conversion of a single action station to a NO GRIP station refer to Installation Instructions cover kit for field installation on 4099 9001 for retrofit refer to page 4 to page 4 for details for details Specifications refer to Installation Instructions 574 332 for additional information and Communications or MAPNET II communications 1 address per station switch 8 position Means Connections terminal for in out wiring for 18 to 14 AWG wire to 120 F 0 to 49 C intended for indoor operation Listed Temperature Range to 93 RH at 100 F 38 F Range with white raised lettering Color and pull lever are Lexan polycarbonate or equal with red raised lettering Lever Color Dimensions H x 3 3 4 W x 1 D 127 mm x 95 mm x 25 mm Addressable Manual Station Semi Flush Mounting Gang Box Mount gang box 2 1 2 deep mm RACO 500 or equal by others Square Box Mount 102 mm square box 2 1 8 54 mm minimum RACO 231 or equal supplied by others flush or with 2 mm extension NOT RECESS Square box cover plate DOWN gang cover plate 3 4 mm extension RACO 773 equal supplied by others view gang outline surface Mount Side View 5 2012 Box separately H x 4 W x 2 3 16 D mm x 102 mm x 56 mm Addressable Manual Stations Surface Mounting Mounting For mounting of these manual stations the electrical boxes are in the illustration to the Mounting Refer to page 4 for box mounting located and bottom Cast Box H x 3 7 8 W x 2 3 16 D mm x 98 mm x 56 mm separately DOWN mm for 3 4 threaded located top and bottom 25.4 mm 95 mm Series Addressable Manual Station Surface Mount Side View with Internal Detail wiring for reference mm 2975 9178 box for reference setting under label accessible cover open cover open for access mm wiring Application Reference to NFPA 72 the National Fire and Signaling Code and all local codes for complete for manual stations The summarizes the basic Stations shall be located in the path of exit and distributed the protected area such that they unobstructed and readily Mounting shall be with the part not less than 42 in m and not more than 48 in m above floor level At least one station shall be on each floor Additional shall be provided to obtain travel distance not more than ft 61 m to the nearest station any point in the building When manual station coverage limited in any way stations should be