Simplex 4099-9001, -9002, -9003 Addressable Pull Station Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4099-9001-9002-9003-addressable-pull-station-installation-instructions-8213704695.pdf |
---|---|
Type | |
Size | 1.30 MB |
Downloads |
Text Preview
Cautions and Warnings 9002 9003 Addressable Station Installation Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of carton for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times 4099 9001 9002 9003 Addressable Pull Stations provide two state status NORMAL and SHORT to the 4010 Fire Alarm Control Panel via the IDNet channel and to the 4100 4120 4020 FACP via the II channel The IDNet and MAPNET II channel s provide the link between pull stations and FACP and powers the entire Pull Station installation consists of the following Setting the Addressable Pull Station address Making electrical connections to the Addressable Pull Station Mechanically installing the Addressable Pull Station this Publication publication discusses the following topics 1 Addressable Pull Station Assembly Page the Addressable Pull Station Address Electrical Connections to the Addressable Station Installing the Addressable Pull E 1999 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice is a trademark of the Simplex Time Recorder Company II Communication Net is protected by U S patent no 4,796,025 the Addressable Pull Address The IDNet channel 4010 FACP only supports address codes 1 through The MAPNET II channel 4100 or 4120 or 4020 FACP supports codes 1 through 127 Addressable Pull Station has a unique address The address of the Pull Station is set via an eight position dip switch Figure 1 DIP position 1 is the least significant bit LSB and position 8 is the most bit MSB Set the Addressable Pull Station address using Figure 2 reference Use a small screwdriver or pen to set the switches The device for the Addressable Pull Station should be written on the re sealable this information provides an aid in troubleshooting the system DIP switch in position is while DIP switch in position is IS SHOWN SET AT ADDRESS 7 ON OFF SWITCHES 5 THRU 8 1000 0100 1100 0010 1010 0110 1110 0001 1001 0101 1101 0011 1011 0111 1111 128 144 160 176 192 208 224 240 129 145 161 177 193 209 225 241 130 146 162 178 194 210 226 242 131 147 163 179 195 211 227 243 116 132 148 164 180 196 212 228 244 117 133 149 165 181 197 213 229 245 118 134 150 166 182 198 214 230 246 119 135 151 167 183 199 215 231 247 120 136 152 168 184 200 216 232 248 121 137 153 169 185 201 217 233 249 122 138 154 170 186 202 218 234 250 123 139 155 171 187 203 219 235 124 140 156 172 188 204 220 236 125 141 157 173 189 205 221 237 126 142 158 174 190 206 222 238 127 143 159 175 191 207 223 239 II supports address codes 1 through 127 only 2 Addressable Pull Station Address Chart FACP IDNet Channel the Addressable Pull Station to the 4010 panel using the 4010 Fire Installation and Programming 574 187 and 4010 Fire Alarm Operating and Programming Instructions 574 052 Refer to 4010 label 526 444 for appropriate revision of the instructions to be used FACP MAPNET II Channel the Addressable Pull Station to the host FACP using the 4100 4120 4020 Programmer Report The Addressable Pull Station address and must match up with the address listed in the specification sheets of the 4120 or 4020 Programmer Report Electrical to the Pull Station IDNet or MAPNET II signal connects to the Addressable Pull Station via 1and 2 Terminals 3 and 4 are factory wired do not use for field Terminal connections for the Addressable Pull Station are illustrated in 3 Do not loop wire under terminals Break wire runs to supervision II IDNet note 1 II IDNet note 1 A or Class B Installation Note 2 II IDNet note 1 II IDNet note 1 Station Connections Wired Station Connections Wired B Installation Note 2 When connecting two wires to one terminal position one wire on each side of the screw Maximum allowable run from FACP to farthest device not to 2500 feet Maximum total wire including all T Taps from FACP is 10000 IDNet and MAPNET II lines are 18 AWG twisted pair shield recommended Refer to Field Wiring Diagram 842 073 for further information on wiring Pull Stations to IDNet Refer to Field Wiring Diagrams 841 804 or for further information on wiring Addressable Pull Stations to MAPNET II and MAPNET II wiring are supervised and Power Limited 3 Addressable Pull Station Connections Installing the Pull Station the Addressable Pull Station into an U L Listed single gang or 4 inch electrical box not supplied using Figure 4 as a reference for Glass Replacement hammer A away from front of pull station glass retainer B onto bottom of glass plate Then fit top of glass plate behind tab glass retainer B into station until it snaps place Gently return hammer A to its normal position 4 Addressable Pull Station Back Box Installation VIEW VIEW E