Simplex 4099-9012 & 4099-9802 IDNet or MAPNET II Addressable Manual Station for Releasing Applications Dual action (Push and Pull) [moved location 3 10 08 from Addressable Initiation, IDNet or MAPNET II Devices ]

File Preview
File Preview
Click below to download for free

Text Preview

Releasing System Peripherals II or IDNet Communicating Devices Manual Stations for Releasing Applications ULC Listed FM CSFM Approved addressable manual fire alarm for releasing applications with Power and data supplied via MAPNET II or IDNet communications using a single wire pair Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break rod supplied use is optional Dual action push and pull operation Label kit provides for six varieties of releasing ordered separately with Simplex 4010 4100 4120 4020 fire alarm control equipped with either IDNet or MAPNET II construction Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections resistant reset key lock Locks are keyed the same as Simplex fire alarm cabinets mounting options Surface or semi flush with standard boxes or matching boxes Flush mount adapter kit Adapters are available for retrofitting to commonly existing boxes listed to Standard 38 4099 series addressable manual stations combine familiar Simplex housing with a compact module providing easy installation for applications The integral individual addressable IAM monitors status and communicates changes the connected control panel via MAPNET II or IDNet wiring blank area on the front of the station allows the of a label to match the specific releasing label kit is ordered separately Refer to data S4099 0001 for standard Simplex addressable stations This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7150 0026 224 allowable values and or conditions concerning material presented in this document It is to re examination revision and possible cancellation This product was not approved MEA NYC as of document revision date Additional listings may be applicable contact local Simplex product supplier for the latest status Listings and approvals under Time Recorder Co are the property of Tyco Safety Products Westminster Addressable Manual Station for Releasing front and side view AGENT DIOXIDE SYSTEM Kit requires that a spring loaded interference marked PUSH be pushed back to access the station lever with a firm downward pull that activates the switch Completing the action breaks an internal break rod visible below the pull lever use is The use of a break rod can be a deterrent to without interfering with the minimum pull needed for easy activation The pull lever into the alarm position and remains extended out the housing to provide a visible indication reset requires the use of a key to reset the station lever and deactivate the alarm switch If break rod is used it must be replaced testing is performed by physical activation of pull lever Electrical testing can be also performed by the station housing to activate the alarm switch MAPNET II and IDNet addressable communications designs are protected by U S Patent 4,796,025 6 2003 Addressable Manual Station Product Selection Manual Stations action Push operation Addressable manual station red housing with white letters and white pull requires label kit 4099 9802 kit white lettering on red background select the label required for the specific releasing application include Clean Agent Extinguishing Carbon Dioxide Foam System Sprinkler and Manual mount steel box red Cast aluminum surface mount box red trim plate for double gang switch box red trim plate for Wiremold box V5744 2 red mount adapter kit black mount adapter kit beige Replacement break rod to page 3 for dimensions for retrofit refer to page 4 to page 4 for details Specifications and Communications II or IDNet 1 address per station up to 2500 ft 762 m from fire alarm control up to 10,000 ft 3048 m total wiring distance including T Taps Means 8 position Connections Listed Temperature Range terminal for in out wiring for 18 to 14 AWG wire wire equivalents 18 AWG 0.82 mm2 14 AWG 2.08 mm2 to 120 F 0 to 49 C intended for indoor operation Range Color Lever Color to 93 RH at 100 F 38 F with white raised lettering and pull lever are Lexan polycarbonate or equal with red raised lettering Dimensions H x 3 3 4 W x 1 D 127 mm x 95 mm x 25 mm Addressable Manual Station Semi Flush Mounting Gang Box Mount gang box 2 1 2 deep mm RACO 500 or equal by others Square Box Mount 102 mm square box 2 1 8 54 mm minimum RACO 231 or equal supplied by others flush or with 2 mm extension NOT RECESS Square box cover plate view DOWN gang cover plate 3 4 mm extension RACO 773 equal supplied by others gang outline surface Mount Side View 6 2003 Box H x 4 W x 2 3 16 D mm x 102 mm x 56 mm separately Cast Box H x 3 7 8 W x 2 3 16 D mm x 98 mm x 56 mm separately Addressable Manual Stations Surface Mounting Mounting For mounting of these manual stations the electrical boxes are in the illustration to the Mounting Refer to page 4 for box mounting located and bottom DOWN mm for 3 4 threaded located top and bottom 95 mm 25.4 mm Series Addressable Manual Station Surface Mount Side View with Internal Detail wiring for reference mm 2975 9178 box for reference setting under label accessible cover open cover open for access mm wiring 6 2003 Addressable Manual Station Additional Mounting Information retrofit and new additional mounting boxes the required adapter plates shown in the illustration to right box V5744 2 by gang switch box each H x 2 W x 2 3 4 D mm x 51 mm x 70 mm by others Surface trim Wiremold box H x 5 W mm x 127 mm Semi flush trim for switch box 6 H x 4 1 2 W mm x 114 mm 121 mm 171 mm View Addressable Manual Station Flush Mounting Information mount adapter kit Black Beige must be recessed into wall to 1 1 8 25.4 mm to 29 mm mm cutout must be a of 6 H by 5 W 152 mm by 127 mm 119 mm box 2 1 8 mm minimum by others View Simplex the Simplex logo MAPNET II and IDNet are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries Lexan is a trademark the General Electric Co Wiremold is a trademark of the Wiremold Company 2003 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 6 2003

Related Files