Simplex 4099-9707 IDNet Communicating Devices, External Manual Callpoint; (-2, formatted for 8 5 x 11 inch) (B) (C)

File Preview
File Preview
Click below to download for free

Text Preview

Manual Callpoint IDNet Communicating Devices Addressable Manual Callpoint addressable manual fire alarm with Power and data supplied via IDNet addressable using a single wire pair Enhanced aesthetics Designed for fast and easy installation Designed for EMI compatibility Surface mounting Test key allows the callpoint to be tested without the glass Requires a special key to open the callpoint Simple snap fit to mounting box with Simplex Model series and 4100U addressable manual callpoints with compact module are easily installed to satisfy applications An integral individual module IAM monitors status and changes to the connected control panel via communications and Means Type Connections and Operating Range Range Protection to 95 RH non condensing RAL3001 H x 3 1 2 W x 2 7 8 D mm x 89 mm x 28 mm 8 position spade terminals to 158 30 C to 70 C 1 address per callpoint This product is not presently agency listed Contact your local Simplex product supplier for latest status Addressable Manual Callpoint of the Simplex callpoint requires the glass to be broken Completing the action operates a whose condition is signaled back to the panel reset requires the use of a special key with the callpoint to remove the front cover allows the glass element to be replaced testing is performed by inserting the key into the bottom of the housing and pulling down releases the bottom of the housing and break glass To reset the callpoint the bottom of the housing pushed upwards until it locks in position See below Testing 3 2009 At least one callpoint shall be provided on each floor callpoints shall be provided to obtain a distance not more than 200 ft 61m to the callpoint from any part of the building When manual callpoint coverage appears limited in way additional callpoints should be installed Reference to NFPA 72 the National Fire Alarm Code and all local codes for complete requirements for callpoints The following summarizes the basic Callpoints shall be located in the normal path of exit distributed in the protected area such that they unobstructed and readily accessible Mounting shall be with the operable part not less than ft 1.1 m and not more than 4 1 2 ft 1.37 m floor level Product Selection Manual Callpoints with Internal IAM external English callpoint with LED replacement glass package of 10 Mounting Information Notes Mount the back box to a suitably flat surface using the three fixing holes and the screws provided in the pack The 20 mm cable entry holes should be in the vertical plane The back box can be mounted with either the single or the double entry holes at the top 3 2009 Setting the Callpoint Address Callpoint to Backbox Callpoint from Backbox Ensure that the O ring is correctly seated in the on the rear of the cover Place the cover squarely over the back box and push the cover until the locating clips have Do not use excessive force is recommended that the 4 cover fixing screws are to lock the cover into place The O ring should be replaced when refitting or the Waterproof Cover To remove the cover undo and remove the 4 Cover screws Place the edge of a large flat bladed screwdriver into slot between the Cover and back box as shown and gently twist until the latches are disengaged Pull cover away from backbox 3 2009 the Break Glass Element is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo and IDNet are trademarks of Tyco International Ltd its affiliates and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA 2009 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 3 2009

Related Files