Simplex 4099 Series IDNet Addressable Manual Stations
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4099-series-idnet-addressable-manual-stations-1238546079.pdf |
---|---|
Type | |
Size | 1.02 MB |
Downloads |
Text Preview
Listed addressable manual fire alarm with Power and data supplied via IDNet addressable using a single wire pair Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break rod supplied use is optional models are available Single action operation Double action operation Breakglass or Push Two stage pull station use with Simplex IDNet communications sealed construction Allows mounting in standard electrical boxes spacer Screw terminals for wiring connections Reduces dust infiltration resistant reset key lock keyed same as fire alarm cabinets mounting options Surface or semi flush with standard or matching boxes Flush mount adapter available Adapters are available for retrofitting of existing stations Simplex 4099 Series addressable stations combine the Simplex manual station housing with a compact module that is easily installed to satisfy applications Its integral individual addressable IAM constantly monitors status and changes to the connected control panel via IDNet communications wiring Simplex IDNet addressable communications are by U S Patent 4,796,025 Peripherals Communicating Devices Manual Stations Single Stage Two Stage Breakglass Push of the Simplex 4099 9001 single manual requires a firm downward pull to activate the alarm Completing the action breaks an internal plastic visible below the pull lever use is optional The of a break rod can be a deterrent to vandalism without with the minimum pull requirements needed for activation The pull lever latches into the alarm and remains extended out of the housing to provide visible indication Action Stations Breakglass require the to strike the front mounted hammer to break the and expose the recessed pull lever The pull lever then as a single action station Action Stations Push Type require that a loaded interference plate marked PUSH be pushed to access the pull lever of the single action station reset requires the use of a key to reset the manual lever and deactivate the alarm switch If the is used it must be replaced testing is performed by physical activation of the lever Electrical testing can be also performed by the station housing to activate the alarm switch 2000 Simplex International Time Equipment Co Ltd All rights reserved 7 01 Addressable Manual Station Product Selection Manual Stations Options action addressable manual station action addressable manual station Breakglass operation action addressable manual station Push operation addressable manual station addressable manual station with N C Contact addressable manual station Breakglass operation addressable manual station Breakglass operation with N C Contact action addressable manual station with N C Contact action addressable manual station Breakglass operation with N C Contact shown are English Language 4099 9001 add for French for Bilingual 4099 9001 4099 9001CF 4099 9001CB all other models add for French for Bilingual e g 4099 9004CA 4099 9004CAF 4099 9004CAB Accessories mount steel box red aluminum surface mount box red trim plate for single gang box red trim plate for Wiremold 5744 2 red mount adapter kit black mount adapter kit beige breakglass break rod to page 3 for dimensions for retrofit refer to 4 to page 4 for details 1 address per station up to 2500 ft 762 m from fire alarm control panel up to ft 3048 m total wiring distance including T Taps 8 position terminal for in out wiring for 18 to 14 AWG wire Listed Temperature Range F to 120 F 0 C to 49 C intended for indoor operation and Communications means Connections Range Colour Lever Colour Dimensions to 93 RH at 100 F 38 C with white raised lettering and pull lever are Lexan polycarbonate with red raised lettering H x 3 3 4 W x 1 D 127 mm x 95 mm x 25 mm 7 01 Page 2 Manual Station Mounting for 4099 9001 9002 9003 D SIMPLE STANDARD RACO N 773 APPLETON N 8468 STEEL CITY N 52C 14 PAR D POUR CONDUIT 3 4 19 MM EN HAUT EN BAS DU BO PAR SIMPLEX EN STANDARD DE 2 1 8 5.39cm DE PROFONDEUR RACO N 231 APPLETON N 4SD 3 4 OU 4SD SPL STEEL CITY N 52171 3 4 OU 52171 1 2 3 4 NE PAS UTILISER UN BO PEU PROFOND DU MUR BOX NO 57441S DEEP TRIM RECEPTACLE BOX 2099 9814 BOX BOX FOR THREADED INCH 1.9cm CONDUIT TOP BOTTOM OF BOX BY SIMPLEX 1 2 3.65cm DEEP SINGLE GANG BOX NOT FURNISHED BY SIMPLEX NO 500 APPLETON NO 222 OR STEEL NO CDOW BOX NO 5747 FURNISHED BY SIMPLEX NUT 3 SWITCH BOX x 2 x 2 3 4 BOXES GANGED TOGETHER TRIM FOR SWITCH BOX 2099 9813 Reference to N B C 3.2.4.12 for requirements on manual pull stations to CAN ULC S524 Section 5 2 for the requirements on the installation of manual pull stations 7 01 Page 3 Manual Station Mounting for 4099 9004 9005 9006 9007 9008 9009 the Simplex logo and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co in the U S and or other countries NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Lexan is a registered trademark of the General Electric Co FOR THREADED INCH 1.9cm CONDUIT TOP BOTTOM OF BOX BY SIMPLEX 2975 9312C BOX NO 5744 FURNISHED BY SIMPLEX CONDUIT ENTRY CONDUIT ENTRY TRIM RECEPTACLE BOX 2099 9814 BOX NO 5744 2 DEEP SPACER BY SIMPLEX REAR CONDUIT ENTRY BOX FURNISHED BY SIMPLEX REAR CONDUIT ENTRY HOLES BACK CONDUIT ENTRY HOLES TRIM MBD 2 K BOX 2099 9813 BOX 7 01 Skymark Avenue Mississauga Ontario L4W 5K5 and Representatives Throughout the World us on the world wide web at www simplexnet com specifications and other information shown were current as of printing and are subject to change without notice Printed in Canada