Simplex 4100-0154, 4100-6048, VSR-13D01-S04 High Level Interface to VESDA Air Aspiration Detectors for 4100ES 4100U 4100 4010ES Series Fire Alarm Control Panels
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
UL ULC Listed Approved Fire Alarm Systems Level Interface to VESDA Air Aspiration Detectors for Series Fire Alarm Control Panels communications between Simplex fire control panels and VESDA air aspiration detection systems mission critical high value applications to advised of very low level smoke activity early response system communications include Smoke obscuration threshold levels Air flow components status Detector head status Sensitivity settings detection panel features include Panel operation can be programmed to recognize and up to three smoke levels from up to 30 VESDA smoke detectors can gathered on one communications input Can perform Reset Enable and Disable of each VESDA smoke detector with Simplex 4100ES 4100U 4010ES and legacy fire alarm control panels VESDA models LaserPLUS VLP LaserSCANNER LaserCOMPACT VLC and LaserFOCUS air aspiration smoke detection systems Panels require software version 8 or higher listed to Standard 864 High Level Interface HLI allows addressable fire detection panels to gather and status information from VESDA high sensitivity aspiration smoke detection systems Hardware include an Intelligent Interface Module in the fire alarm control panel and an HLI and associated VESDA equipment installed in a enclosure Warning The combination of VESDA smoke and the extensive features of the Simplex panel allows mission critical and high value to be equipped with a low level smoke detection that can provide very early warning of the of incipient fire conditions air inlet Air Aspiration Detection System level smoke in West cable tray PLUS GRAMM ER Esc net link GRAMM ER Esc High Level Interface HLI and associated equipment 19 rack mount with box 232 data WING CLEAN ROOM DETECTOR ALARM Alarm Control Panel with Interface Module shown for reference Control Panel Communicates with VESDA Smoke Equipment via High Level Interface HLI The High Level Interface has been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this MEA NYC acceptance is not applicable for this product type This product was FM approved as of document revision date Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of SimplexGrinnell LP Westminster the Simplex VESDA HLI communications link VESDA smoke detectors are connected to the alarm control panel as remote addressable devices connection provides remote monitoring of the locally displayed information and allows the to provide remote control for Reset Enable and of the VESDA smoke detector Interface Applications Critical High Value All facilities containing and material need to be adequately protected from and fire However some facilities have missions are extremely critical as well as contents of high value and may benefit from integrating early smoke detection into their facility fire detection HLI Interconnection Information Interface Applications Continued Critical Typical examples of mission critical applications would be telephone switching semiconductor clean rooms computer rooms research laboratories With such facilities loss of can result in significant economic impact Value Other types of facilities such as libraries and museums may not be burdened by short of downtime but their high value contents are irreplaceable objects that deserve extra the earliest indication of a potential fire condition facilities need the ability to dispatch trained to investigate and repair wiring problems or malfunction In some instances saving a few in response time may avoid extensive downtime avoid smoke damage to delicate equipment or a work of art For additional High Level Interface refer to VESDA Hardware Configuration Instructions 574 050 Air Aspiration Detection System VSR 13 D 01 S 04 VESDA High Level Module and associated equipment in 19 rack with box includes a programmer a VESDAnet socket RS 232 connection for the fire alarm panel GRAMM ER Esc net link GRAMM ER Esc Fire Alarm Control mounted VESDA Intelligent Module shown for reference wiring 4 wire RS 232 compatible cable total length not to exceed 20 ft 6 m 232 Cable assembly with 4 1 2 ft 1.3 m leads supplied with the Intelligent Interface Module Smoke Detection Summary VESDA air aspiration family of smoke detectors sophisticated combinations of air intake air filtering intensity laser photoelectric sensing and unique applications to provide extremely early of incipient fire conditions By linking the analog of a VESDA smoke detection system to a Simplex fire detection panel it is possible to those conditions well before they become a A complete description of the extensive available with VESDA systems is beyond the of this document Please refer to the specific product literature for further details Product Selection and Reference Alarm Control Model Series Number and 4100U Interface Module mounted in fire alarm control panel Each Intelligent Interface Module reduces MAPNET II or IDNet for 4100ES 4100U 4010ES addressable communications channel by one VESDA Smoke Detector Equipment Reference VESDA High Level Interface board a VESDA programmer and a VESDAnet socket all in a 19 equipment rack within a mounting box rack provides two unused slots for additional VESDA accessories such as Programmers Detector Displays etc VESDA processing note To order additional Xtralis products in JobDesign AOP query use OPVIS or vendor Xtralis to documentation supplied with the specific VESDA Smoke Detector Equipment for additional and information smoke detection systems are supplied by Xtralis www xtralis com VESDA Specifications Control Panel Mounted Intelligent Interface Module to 32 VDC from control panel mA 9600 baud maximum distance is 20 ft 6 m Requirement module requires 2 internal rack width 51 mm Listed Temperature Range F to 120 F 0 C to 49 C Range to 95 RH non condensing Level Interface Module VSR 13D01 S04 Mounted in VESDA Smoke Detector mA to 32 VDC from the VESDA Smoke Detector Equipment is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo LifeAlarm MAPNET II and IDNet are trademarks of Tyco Ltd and its affiliates and are used under license Xtralis VESDA LaserPLUS LaserSCANNER LaserCOMPACT LaserFOCUS and VESDAnet are trademarks property of Xtralis Pty Ltd LP Westminster Westminster MA 01441 0001 USA 2011 Tyco All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice