Simplex 4100-3106 4100ES IDNet expansion module with QuickConnect and QuickConnect2 sensor compatibility (B) S4100-0041-3 2 11 4100-3115 XA Loop Interface to the 4100ES Fire Alarm Control Panel (B)
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
CSFM Listed FM Approved NYC Acceptance Control Panels XA Loop Interface to the 4100ES or 4100U Fire Control Panel Module 4100 3115 the Simplex 4100ES or 4100U to operate either an XA Loop Master Panel or an XA Loop Gathering Panel operating as an XA loop Master Panel Connects to up to 255 input devices and up to 255 output on a single XA loop to monitor supervise and Monitoring status includes Normal Trouble or Alarm XA loop devices can be 4 wire if command output are used or 3 wire if used for monitoring only XA loop devices appear to the 4100ES 4100U similar to addressable devices including custom labels up to 40 characters operating as an XA loop Data Gathering Panel Communicates status and receives control from the XA Autocall compatible Master Panel Control includes Acknowledge Silence Reset and level commands 4100ES 4100U operates as a stand alone fire alarm panel for its connected devices and appliances or 4100U panels equipped with Simplex communications can send XA loop information to other Network nodes Flexibility When a fire alarm system using XA loop devices requires expansion use of the XA Loop Interface Module allows the to include the capabilities of the 4100ES or fire alarm control panel This module allows the control panel to be selected to function as either the loop master controller head end or as a Data Panel as an intelligent device on the XA loop to a remote master controller XA Loop Interface Modules can be in the 4100ES 4100U allowing a variety of expansion situations to be satisfied The accepts up to a total of 30 modules of this which also includes IDNet modules MAPNET II and VESDA modules LEDs are provided for service diagnostics to XA loop status internal 4100ES 4100U status and supervision status when as a master controller for the XA loop additional information refer to Installation and Guide 579 513 This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7165 0026 251 rise and 7170 0026 250 high rise for allowable values and or conditions material presented in this document It is subject to re examination revision and cancellation Accepted for use City of New York Department of Buildings This product was not ULC listed as of document revision date Additional may be applicable contact your local Simplex product supplier for the latest status and approvals under Simplex Time Recorder Co are the property of Tyco Safety Westminster XA Loop Interface Block Diagram Specifications Requirements VDC from expansion bay supply if present or wired AUX and AUX from 24 VDC in panel mA 24 VDC Loop Specification Reference Resistance per wire Capacitance wire to wire wire to shield mA VAC 250 Hz Addresses per Loop 255 Specifications Temperature Range F to 120 F 0 C to 49 C Range Wiring Connections to 93 RH non condensing 90 F 32 C x 10 102 mm x 254 mm requires two vertical bay blocks terminal blocks for field 18 to 12 AWG 0.82 mm2 3.31 mm2 XA Loop Interface System Diagram Master Panel Operation XA Loop Interface System Diagram Data Gathering Panel Operation is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo IDNet AUTOCALL and MAPNET II are trademarks of International Ltd and its affiliates and are used under license VESDA is a trademarks of Xtralis Pty Ltd Safety Products Westminster Westminster MA 01441 0001 USA 2011 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice