Simplex 4100-6069 and 4010-9915 BACpac Ethernet Module (B)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4100-6069-and-4010-9915-bacpac-ethernet-module-b-2938516704.pdf |
---|---|
Type | |
Size | 792.38 KB |
Downloads |
Text Preview
ULC CSFM Listed mounted modules provides fire alarm status using the ASHRAE BACnet automation communication protocol Building Automation Control Network reference Communications are via BACnet IP internet protocol Reference ANSI ASHRAE Standard 135 To fire alarm system via RS 232 port B configured Computer Port Protocol see page 3 for model reference per panel Output port provides Ethernet LAN local area connection Ethernet Module is pre programmed Module is pre programmed with digital pseudo points to BACnet objects Up to 1000 status changes monitor point status can recognized from the fire alarm control panel Simplex fire alarm control panels 4100ES and 4100U Series fire alarm control panels Network Display Units NDU 4010ES Series fire alarm control panels legacy Models 4100 4100 and 4120 Series alarm control panels and NDU software revision may be required reference UL listed to Standard 864 ULC listed to Standard S527 BACpac Ethernet module provides a supplementary interface that converts computer terminal from a compatible Simplex fire alarm control into the building automation protocol of BACnet this module status information from the fire alarm panel can be provided to other components of the automation network with the detail and format required this information allows other systems to respond to fire alarm system activity in addition the primary fire alarm response that is under the control the fire alarm control panel Control Panels Ethernet Portal Modules 4100 6069 and 4010 9915 LAN Connected BACnet System Controllers LAN DOWN DOWN alarm initiating devices Control Alarm SYST EM IS NORMAL 2 02 15p m Mo n 8 Ma r 99 IR E ARM TEM ERVI SO R EM BL M ENC ED C OWER ARM CK P K OU BLE M LE N CE TEM ES E RE ALARM ER BEFORE BACpac Module Fire Alarm Panel Alarm System Building Automation LAN with Fire Alarm Control Panel and BACpac Portal with 4100ES panel for reference document is a summary of the flexibility available BACnet communications Please contact your local product supplier for further information your specific application This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 4100 Series or 7165 0026 0369 4010ES for allowable values and or concerning material presented in this document It is subject to re examination and possible cancellation This product was not approved by FM or accepted by NYC as of document revision date Additional listings may be applicable contact local Simplex product supplier for the latest status Listings and approvals under Time Recorder Co are the property of Tyco Fire Protection Products 9 2012 FLOOR SMOKE ALARM LAN protocol format Instance 1 LAN M1 1 M1 1 Fire Panel fire BACpac Ethernet and 4010 9918 Module BACpac Ethernet Module Process Reference with 4010ES panel for reference Responsibilities Detection and Alarm Systems are distributed buildings to monitor for indications of the of smoke or fire When a fire alarm condition is the fire alarm system communicates that with sufficient detail to allow the proper fire to begin The fire alarm system may perform control functions such as fan shutdown and elevator or those actions may be performed by other that also handle those functions for normal as well as for abnormal conditions Automation Systems As buildings increase size and complexity control of the electrical and systems requires coordination This process evolved into the general category of Building Systems and includes systems such as heating and air conditioning HVAC elevator security controls lighting controls and other building functions responses to fire alarm system status changes include HVAC fan control operation elevator lighting control and security system awareness examples could include turning on lighting needed aiming security cameras on specific areas door release and implementing detailed fan and or pressurization instructions Communications Between Systems Traditional between systems has included simple relay proprietary and complicated interface devices as well as using a single supplier for all of the automation functions Each of these compromises its limitations With the Simplex BACpac Ethernet BACnet protocol communications allows a fire alarm system to provide pertinent status to systems using standardized formats Example example to the right shows how a smoldering fire on the first floor can be detected by the fire alarm panel processed by the BACpac Ethernet module then sent to the building automation system using the protocol over a LAN connection It is the of the fire alarm control panel to initiate the notification and related fire responses However connected to a BACpac Ethernet module the fire system can make status information available to the building systems allowing them to be informed facility fire detection activity Reference module uses a BACnet protocol converter from Technologies PC compatible diagnostic are available at www fieldserver com 9 2012 Product Selection RS 232 Module separately Data Reference Ethernet Module for 4100ES 4100 4100 and 4120 Series fire control panels single slot 2 module or 4100 4120 Ethernet Module for 4010ES Series alarm control panels single block 4x5 for Note BACpac modules connect to Port B of these RS 232 modules BACnet Protocol Implementation Conformance PIC Reference Standardized Device Profile L Smart Sensor B SS Smart Actuator B SA Application Specific Controller B ASC Interoperability Building Blocks Annex K BIBB Data Sharing ReadProperty B DS RP B BIBB Data Sharing WriteProperty B DS WP B BIBB Device Management Dynamic Device Binding B DM DDB B Capability Object Types Supported NOT Property Details Link Layer Options Address Binding Sets Supported Object Input Output Value Input Output Value State Input Output State Output State Value CreateObject DeleteObject optional properties supported X3.4 10656 ICS 4 10656 UCS 2 8859 1 DBCS Details additional writeable properties exist proprietary properties exist range restrictions exist master Clause 9 baud rate up to 76,800 bps slave Clause 9 baud rate up to 76,800 bps 9 2012 Specifications Power Input Connect to B of RS 232 Output 24 VDC from fire alarm panel operation range 9 to 30 VDC 123 mA maximum from 24 VDC fire alarm panel supply Wires to pluggable terminal block harness included Type RS 232 Computer Port Protocol from fire alarm control panel Pluggable terminal block same terminal block as used for input power connects to module in fire alarm control panel harness included