Simplex 4100-7401, 4100-7402, 4100-74003, 4100-7404 4100 Series Graphic Annunciator Modules; LED Switch Modules and 24 Point I O Graphic Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4100-7401-4100-7402-4100-74003-4100-7404-4100-series-graphic-annunciator-modules-led-switch-modules-and-24-point-i-o-graphic-module-1538062947.pdf |
---|---|
Type | |
Size | 820.83 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Accessories LED Annunciators 4100 Series Graphic Annunciator Modules Modules and 24 Point I O Graphic Module modules for LED and switch control of graphic annunciator panels including 4100 7401 24 Point I O Graphic Modules with points as either switch inputs or LED outputs 4100 7402 64 Switch and 64 LED Driver Module 32 on board LED drivers 4100 7403 32 Point LED Driver Modules 4100 7404 32 Point Switch Input Modules compatibility For use with Simplex 4100ES 4100U and 4010ES fire alarm control panels Also compatible with Simplex legacy panel model 4100 4120 and 4020 see 4020 compatibility on page 2 mounting options are available Semi flush or surface mount cabinets in beige or red or without glass door modules can be mounted in the same cabinet graphic panel or mounted nearby Plate mounted for mounting in cabinet by others modules are UL listed for use in agency custom graphic annunciator panels and status supervision Supervised RUI remote unit interface require a single twisted wire pair applications may require shields to the fire control panel power is supplied via a second pair Multiple annunciator module types can be connected same communications wiring Convenient wiring connections are via pluggable blocks listed to Standard 864 for Fire Detection and Control UOJZ Smoke Control Service UUKL Control These remote annunciator control modules complement Simplex 4100ES 4010ES and other installed legacy panels by LED lamp relay drivers and switch inputs to custom graphic displays to be designed for specific requirements such as for smoke control UUKL Wiring is minimized by Signaling Line Circuit communications that also provides supervision the event of communications loss a trouble will be at the fire alarm control panel and can also be at the remote annunciator if desired additional ARM SIL ENCED AL ARM ITY 2 AL ARM SYSTEM SUPERVISORY SYST EM TROUBLE POW ER ON ARM SIL ENCE SYSTEM RESET DISPL AY TIME ARM ACK SUPV ACK TBL ACK ARM ACK 9101 LCD Annunciator shown for reference mounted graphic interface modules E 6 STAIR BBY 6 WATCH T OUR STAT ION 2 E 2 16 L STAT IO N WATCH T OUR STAT ION 3 A 2 17 AUS T E 1 604 KE DET ECT OR A 1 WATCH TOUR STAT ION 1 ROOM KE DET ECT OR SENSOR STAIR Graphic Annunciator Panel Communications power wiring Control Fire Alarm Control Panel for reference Fire Alarm Control Panel Connected to a Remote Annunciator and a Remote LCD Annunciator Continued Flexibility For packaging flexibility these are plate mounted allowing compatibility with graphics assemblies These modules also provide terminal block wiring connections and use ribbon cable connectors for multiple module This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of SimplexGrinnell LP ACK located under flashing indicator Repeat operation until all events are acknowledged Local tone will silence A B CAC PowerD E FG H IJ K LM N OP Q R 0 S T UV W XY Z ALARMSFire AlarmPriority 2 AlarmSYSTEM WARNINGSSupervisoryTroubleAlarm SilencedEmergency Operating InstructionsAlarm or Warning ConditionHow to Acknowledge View EventsHow to Silence Building SignalsSystem indicator flashing Tone On Press Alarm Silence How to Reset SystemPress System Reset Press Ack to silence tone device ZONE1SIG2AUX3FB4IO5IDNet6P7A8L9NETADDR0DELEnterC ExitFire AlarmAckPriority 2AckSupvAckTroubleAckAlarmSilenceSystemResetEventTimeEnableOn ArmDisableOffDisarmAutoLampTestMoreInfoMenuPreviousNextfirealarmresources com Control Module Descriptions 24 Point I O Graphic Module 64 64 LED Switch Controller Module 24 Points selectable as either a switch input or a Support for up to 64 switches and 64 LEDs switches are driver output Switch monitoring includes unsupervised supervision opens supervision for opens or shorts and monitoring of HOA hand off auto switches Switches can be momentary or maintained 2 position or position maximum distance is 2500 ft 762 m or from the module Each LED lamp relay driver is rated at 150 mA VDC per point inrush is current limited for with incandescent bulbs relays need to be suppressed at the relay coil maximum distance is ft 183 m or 2 from the module LED lamp relay driver outputs are supervised for open and can be set as on continuous or pulsed at a or fast rate Additional inputs are included for communicating a power supply trouble and for lamp testing the can also be configured to provide local of communications loss NOTE 4100 7401 is not compatible with installed 4020 Series fire alarm control panels 32 LED driver outputs on board for direct LED Full capacity is achieved by using a 4100 7403 32 Point Driver Module and two 4100 7404 32 Point Modules Multiplexed LED drivers provides 40 mA peak 5 mA 60 Hz rate 12.5 duty cycle for direct LED and can be steady on or slow or fast pulse LEDs are supervised for open circuits LED and switch connections are supervised LEDs or switches can be up to 25 ft 7.6 m or 3 from 32 Point LED Driver Module Provides an additional 32 LED drivers for use with the Controller LED output is the same as for the 4100 7402 32 Point Switch Module Monitors momentary or maintained 2 or 3 position Switch position sampling is multiplexed at a 60 Hz rate duty cycle 40 mA maximum 5 mA average Module Mounting Reference x 12 1 4 165 mm x311 mm 4100 74034100 74044100 7404Annunciator mounting platewith 1 4100 7402 64 64LED Switch Controller 1 4100 7403 32 PointLED Driver and 2 4100 7404 32 PointSwitch ModulesAnnunciator mounting platewith 3 4100 7401,24 Point I O Graphic ModulesMounting plate dimensions 12 3 8 H x 21 1 2 W 314 mm x 546 mm 4100 7403 7404 dimensions 3 1 4 x 12 1 4 83 mm x 311 mm 4100 74016 1 2 x 12 1 4 4100 7401 4100 7401 firealarmresources com Product Selection Type select one mounted graphic modules modules only plate mounted addition modules only Modules select as required refer to page 2 for panel mounting dimensions Information Point I O Graphic Module is on dedicated mounting plates up to 3 per plate LED Switch Controller Point LED Driver Module Point Switch Input Module Rules 4100 7402 64 64 LED Switch Controller mounted per plate the same can mount one 4100 7403 32 Point LED Driver Module and two 32 Point Switch Input Modules mounting plate requires 2 units of space 1 plate per 2 unit cabinet 2 per 4 unit cabinet 3 plates per 6 unit cabinet These 4100 series graphic modules are available internally mounted and UL listed in custom graphic annunciator panels and graphic smoke control annunciators from Space Age Electronics Inc website www 1sae com Size Finish and Trim Options select as required if 4100 8401 assembly box with glass door retainer only no door finish option trim option beige 1 7 16 wide 37 mm trim option red 1 7 16 wide 37 mm Solid Door for cabinet only models