ULC FM Approved expanded content display interface for 4010ES Series fire alarm control panels for 4010ES Fire alarm control panels stand alone or requires two bay cabinet Remote InfoAlarm Command Centers that mount in a cabinet 4010ES control panels support InfoAlarm Command Centers independent of panel display type UL listed to Standard 864 Command Centers provide customized convenience in System primary display choices include and Most Recent First 5 and Most Recent First 8 Plan with activity status icons General Alarm or to List selectable individually by event type System reports are easily viewed logs can be read with scrolling required Up to six per screen provide functions that with the particular screen information aiding to determine how to proceed Up to two languages are available per system easily by programmable key press systems with or 2 x 40 LCD panels or annunciators one language to be the default font models allow customized language legends operator keys and status LEDs properties 320 x 240 dot matrix QVGA display provides an active of 4.53 W x 3.4 H 115 mm x 86 mm displaying to 854 characters using standard ASCII character font Bright white LED backlighting provides efficient and lasting illumination operation is selectable as or off with power fail or with no key presses more information The InfoAlarm Command provides an expanded content multi line LCD that requires minimal key presses to access detailed Because it is system powered its detailed is provided without requiring separate equipment Command Center Control Panel By using larger area format instead of an individual text line display LCD provides text information for Alarm Priority 2 or Trouble The format is flexible and able to be per application allowing additional information to presented to suit the specific application Control Panels InfoAlarm Command Center the 4010ES Fire Alarm Control Panel Command Center for Control Panel Mounting Command Center in Remote Cabinet Series InfoAlarm Command Centers for 4010ES fire systems provide a large display with extended content dual language support including 2 byte languages and an intuitive control key interface the following Up to 10 InfoAlarm Command Centers are supported per control panel able to allow one InfoAlarm Center to take control and to designate access for interfaces not in control LEDs can be for in control status indications Menu driven format conveniently prompts operators for next action required Key controls are provided to select the highlighted entry next screen of information or jump to top or of activity lists Direct point callup displays individual points and then homes in on the logical choice as point information is entered A Site Plan bitmap can be displayed for reference icons be added to indicate system status Up to 50 custom point detail messages can be generated Date formats are either MM DD YY or DD MM YY Time formats are either 24 hour or 12 hour with AM PM System Normal screen supports a gray scale bitmap for location name company logo or site plan Additional listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of LP Westminster B CD E FG H IJ K LM N OP Q R S T UV W XY Z ZONE1SIG2AUX3FB4IO5IDNet6P7A8L9NETADDR0C ExitMenuEnterPreviousNextPage DnPage UpACPowerALARMSFire AlarmPriority 2AlarmWARNINGSSystemSupervisorySystemTroubleAlarmSilencedFire AlarmAckPriority 2AckSupvAckTroubleAckAlarmSilenceSystemResetfirealarmresources com Control Panel Operation Reference Refer to page 5 for international control panel reference information B CD E FG H IJ K LM N OP Q R S T UV W XY Z ZONE1SIG2AUX3FB4IO5IDNet6P7A8L9NETADDR0C ExitMenuEnterPreviousNextPage DnPage UpACPowerALARMSFireAlarmPriority 2AlarmWARNINGSSystemSupervisorySystemTroubleAlarmSilencedFire AlarmAckPriority 2AckSupvAckTroubleAckAlarmSilenceSystemResetSEVEN PROGRAMMABLEFUNCTION SWITCHES eachequipped with dual color LEDindicators the top six LEDs areselectable as either red oryellow the bottom LED isselectable as either red orgreen NOTE Program thebottom switch as LampTest for UL listed systemsGround FaultCustom label insert typicalchoices shown for reference THREE PROGRAMMABLELEDs provide custom labeling the top two LEDs are selectableas red or yellow the third LED isselectable as red or greenULC SYSTEMS requiredesignating a Ground FaultindicatorWaterflow WestWaterflow EastLCD NAVIGATIONCONTROL Menu Enter Previousitem select Next itemselect Page Up andPage Down320 x 240 DOT MATRIX DISPLAY WhiteLED backlighting provides easy viewing operation is programmable for key inactivitytimeout and or AC power failPRIMARY ACTIVITY IN SYSTEM DISPLAY OPTIONS Choices include First8 shown below for Fire Alarm in System First and Most Recent First 5 and MostRecent Site Plan General Alarm or Direct to List After the event isacknowledged screen reverts to thesequential event list until Clr Exit softkey isselected or after timeout 30 seconds applicable to Fire Alarm Priority 2 Alarm System Supervisory and System Trouble each category is independently selectablefor primary display modeSIX SOFT KEYS are available whenrequired This sample provides Menuto call up the available operations More Info to call up specific pointdetails Site to call up the Site PlanGraphic Screen Event Time whilepressed displays time and date for alldisplayed events and Clr Exit thefollowing are other typical soft keys Point Enable and DisableForce On or ArmForce Off or DisarmReturn On Off orArm Disarm to Auto ModeEvent Time RequestMore Information RequestFIRE ALARM ACK acknowledges a Fire Alarm condition logs theacknowledge silences the operator panel and all annunciator tone alerts and displays sequential alarm listPRIORITY 2 ACK acknowledges a Priority 2 Alarm condition logs theacknowledge silences the operator panel and all annunciator tone alerts and displays sequential Priority 2 alarm listSUPV ACK acknowledges system supervisory conditions logs theacknowledge silences the operator panel and all annunciator tone alerts and displays sequential supervisory condition listTROUBLE ACK acknowledges system troubles logs theacknowledge silences the operator panel and all annunciator tone alerts and displays sequential trouble listALARM SILENCE causes notification appliances to be deactivated typically after evacuation is complete and while alarm source is beinginvestigated May be programmed to silence audible notification andallow visible notification to continue strobes still flashing SYSTEM RESET restores control panel to normal when all alarmedinputs are returned to normalCity DisconnectManual EvacDoor HolderBypassDrillLanguageToggleSmoke SensorAlmost Dirty CheckLamp TestNUMERIC KEYPAD forpoint category and pointselection alphabetcharacters are not usedat this time C Exit Key duplicatesthe Clr Exit softkeywhen presentSIX SYSTEM STATUS INDICATORLEDs provide system status indicationsin addition to LCD information LEDs flashto indicate the condition and then whenacknowledged remain on until reset Fire Alarm Priority 2 Alarm red LEDSupervisory Trouble yellow LEDAlarm Silenced yellow LEDAC Power green LED on for normal firealarmresources com Display Feature Reference shown actual size KEYS in thiscolumn correspond tothe panel pushbuttonswitches programmingallows the soft keys toappear only when thefunctions are enabledFONT ATTRIBUTES include Normal Bold Underline Double Dim Reverse Flash On Off Flash On Dim andcommands for Vertical and Horizontal PlacementCOMMAND PROMPT advises the operator of the action required and displays local panel timeMOST RECENT advises of the time date device type and custom label ofthe most recent occurrence of the list shown in this case the Fire Alarm listFIRST OCCURRENCES UP TO 5 AND MOST RECENT OCCURRENCE ACTIVITY IN SYSTEM DISPLAY Fire Alarm in System screen shown for reference see page 2 for a First 8 Events display FIRST OCCURRENCE advises of the time date device type and custom label of thefirst occurrence of the event type displayed the numerical count identifies thesequence of occurrence when selected as the primary display screen display of firstoccurrence and most recent occurrence is maintained until events are acknowledgedwhich brings up the event list similar to the First 8 display the display reverts back to First and Most Recent when the Clr Exit softkey is selected or after a time delayTALLY COUNTS list the number of activities per category of Fire Alarm FIRE Primary 2 Alarm PRI2 Supervisory SUPV and Trouble TRBL DISPLAY SIZE 4.53 W x 3.4 H 115 mm x 86 mm firealarmresources com Plan with