Simplex 4100 Basic System Description Video Transcript
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4100-basic-system-description-video-transcript-1860937254.pdf |
---|---|
Type | |
Size | 962.48 KB |
Downloads |
Text Preview
Basic System Description Transcript 1989 Simplex Time Recorder Co Gardner Mass 01441 0001 U S A Manuals Online 10 89 Manuals Online you begin you must have a of Publication FA4 91 218 4100 Fire Alarm system contains major components Master Master Power Supply Battery Charger and Master Termination Board These components make up a complete basic fire alarm system Master Controller contains a Unit The Master Power power to the Master Controller devices are connected the Controller Termination Board Battery Charger known as Class Master Controller provides up to initiating device circuits You may each circuit two wire Style operation or four wire Style D operation known as Class A Only these circuits can accept pull stations For the 4100 system accept you must modify system by programming and by removing a capacitor each circuit When used mechanically highest priority devices such as devices the system circuit Master Controller also provides indicating appliance or signal Each individually rated for 2 amps at 24 volts DC fuses are located on the Master A separate harness to the Master Controller signal power for Signal Circuits and 2 The Master Controller Board also provides Y formerly known as Class B or Z formerly known as Class A the Master Power your choice of circuit SYSTEM Master Controller Master Power Supply Battery Charger Master Controller CONTROLLER 8 Initiating Device Circuits P Wire Style B Formerly Class B 4 Wire Style D Formerly A Can Accept Devices CONTROLLER 8 Initiating Device Circuits Manuals Online Manuals Online may control a 64 64 LED Switch Controller annunciator driver maximum of 64 LEDs and 64 A ribbon cable connected Master Controller Connector PlO a row of LED and LED switch modules accesses CONTROLLER 8 Initiating Device Circuits 2 Indicating Appliance Circuits 2 Auxiliary Relays PDT 1 Trouble Relay PDT Master Controller has these city circuits 24 volts reverse box and form contacts possible use a radio master as well as a D A C T Digital Alarm Transmitter energy master box shunt system use these city connection circuits must configure and software For the system you must set the Master system software you must program the desired output the desired city CONNECTION Reverse Polarity Local Energy Master Box Shunt Master Box Form Contact Radio Master Box DACT 71 panel which Master Controller also provides an two line by 40character keypads about the system and for system points panel also has obtaining The CONTROLLER Circuits 8 Initiating Device Circuits 2 Indicating 2 Auxiliary Relays 1 Trouble Relay PDT 64164 LED Switch City Connection Manuals Online Manuals Online are some of the Master Controller P3 of the Master ribbon cable from P7 of the Master Supply provides 24 volts and 8 volts power for the Master Controller All troubles are reported Controller via this cable the Pl of the Master PlO of the Master harness Supply provides signal power for the Controller an alarm condition This harness not supervised signal circuits CONTROLLER ii P5 P8 MSTERF mmam CONTROLLER NO 733 523 CONTROLLER ribbon cable from P7 of the Master P7 of the Master Controller Board provides of the master signal so as to provide supervisory alarm power This cable not however align the cable blue with Pin 1 on both ends Do not or disconnect cable during alarm condition This ribbon cable supervised p5 Manuals Online Manuals Online Manuals Online Manuals Online Manuals Online Manuals Online