Simplex 4100+ Firefighters Audio System Operating Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4100-firefighters-audio-system-operating-instructions-6340519782.pdf |
---|---|
Type | |
Size | 665.90 KB |
Downloads |
Text Preview
4100 OPERATING INSTRUCTIONS FOR FIREFIGHTER AUDIO SYSTEM CHANNEL AUDIO SAFETY AND THE SAFETY OF THOSE AROUND YOU ALWAYS COMES FIRST taken during a fire depend upon local practices sure you know what to do FIRE ALARM LED ALARM MAIN CONTROL PANEL SILENCED TALK 1 2 3 4 5 6 7 8 PIEZO 2 TO OPERATE MIKE TO OPERATE MICROPHONE To make an announcement with mike ALL AREAS Flip up ALL SPEAKERS TALK switch SPECIFIC AREAS Flip up all desired Speaker Select AREA IN ALARM Go to step 2 Remove mike from enclosure and press Mike Talk Switch Turns off any active tone or message Wait for Talk LED to go on Make appropriate announcement Releasing Mike Talk Switch restarts tone or message if exists When finished flip down ALL SPEAKERS TALK switch all activated Speaker Select Switches Then replace mike TO INITIATE AN EVACUATION SIGNAL TO EVACUATE ALL AREAS Flip up ALL SPEAKERS switch EVACUATE SPECIFIC AREAS Flip up all desired Select Switches then flip up SELECTIVE EVAC To make an announcement over mike see HOW TO MICROPHONE instructions shown above When finished flip down ALL SPEAKERS EVAC switch TO SILENCE FIRE ALARM SIGNALS ALARM SILENCE key silences evacuation tone and lights the ALARM SILENCED LED To silence alarm evacuation signals press Main Panel SILENCE key TO USE LOCAL SPEAKER SWITCH active tone message on panel speaker Flip up LOCAL SPEAKER switch When finished flip down LOCAL SPEAKER switch YOUR SYSTEM SWITCH CONFIGURATION DOES NOT THIS SHEET CONSULT SIMPLEX FOR SPECIFIC SIMPLEX IS LISTED IN THE YELLOW SELECT SELECT SELECT SELECT IS NORMAL 27 SEP 97 SELECT SWITCH OPERATION UP CENTER DOWN Manuals Online 1997 Simplex Time Recorder Co Gardner MA01441 0001 U S A specifications and other information shown were current as of publication and are subject to change without notice INSTRUCTIONS ARE INTENDED TO BE FRAMED AND ADJACENT TO THE CONTROL PANEL FOR READY REFERENCE Operator Instruction Manual for detailed operation TO OPERATE PHONE OPERATION When remote phone is plugged in or remote handset is Ring signal is heard on handset Phone LED flashes at panel Tone sounds at panel Pick up master phone To connect phone flip up Phone Select Switch next to LED Handset ring signal goes off Flashing LED turns on steady Panel tone is turned off Use master phone as required Repeat steps 3 and 4 if another remote handset is lifted phone is plugged in silence the tone without connecting the remote phone up PHONE PIEZO SILENCE switch When finished hang up master phone and flip down Select Switches Remote phone must be unplugged or remote handset If remote phone is off hook more than 10 sec panel tone re sounds and LED flashes TO RESET THE SYSTEM When the alarm condition has been cleared restore or all affected devices in accordance with the provided with each device smoke detector sensor etc Reset the system FIRE ALARM Condition Press the SYSTEM RESET PRIORITY 2 ALARM Condition Open the Operator Panel access door and press the PRIORITY ALARM RESET key on the programmable CON Key Panel The CONTROL Key Panel is located the far left of the Operator Interface Panel a short delay the system will return to normal and dis the following message CASE OF TROUBLE NOTIFY NO A TO OPERATE MIKE TO OPERATE MICROPHONE To make an announcement with mike ALL AREAS Flip up ALL SPEAKERS TALK switch SPECIFIC AREAS Flip down all desired Speaker Switches Remove mike from enclosure Press Mike Talk Switch Wait for Talk LED to go on Make appropriate announcement then release Mike Talk When finished flip down ALL SPEAKERS TALK switch flip to center position all activated Speaker Select Then replace the mike TO INITIATE AN EVACUATION SIGNAL TO EVACUATE ALL AREAS Flip up ALL SPEAKERS switch EVACUATE SPECIFIC AREAS Flip up all desired Select Switches then flip up SELECTIVE EVAC To make an announcement over mike see HOW TO MICROPHONE instructions shown above When finished flip down ALL SPEAKERS EVAC switch flip to center position all activated Speaker Select Then replace mike TO SILENCE FIRE ALARM SIGNALS ALARM SILENCE key silences evacuation tone and lights the ALARM SILENCED LED To silence alarm evacuation signals press Main Panel SILENCE key TO USE LOCAL SPEAKER ALERT SWITCH active tone message on panel speaker Flip up LOCAL SPEAKER ALERT switch When finished flip down LOCAL SPEAKER ALERT TO USE LOCAL SPEAKER EVAC SWITCH audio channel to panel speaker Flip up LOCAL SPEAKER EVAC switch When finished flip down LOCAL SPEAKER EVAC switch OPERATING INSTRUCTIONS FOR FIREFIGHTER AUDIO SYSTEM CHANNEL AUDIO SAFETY AND THE SAFETY OF THOSE AROUND YOU ALWAYS COMES FIRST taken during a fire depend upon local practices sure you know what to do FIRE ALARM LED ALARM MAIN CONTROL PANEL SILENCED TO OPERATE PHONE OPERATION When remote phone is plugged in or remote handset is Ring signal is heard on handset Phone LED flashes at panel Tone sounds at panel Pick up master phone To connect phone flip up Phone Select Switch next to LED Handset ring signal goes off Flashing LED turns on steady Panel tone is turned off TALK 1 2 3 4 5 6 7 8 PIEZO 2 Use master phone as required Repeat steps 3 and 4 if another remote handset is lifted phone is plugged in silence the tone without connecting the remote phone up PHONE PIEZO SILENCE switch When finished hang up master phone and flip down Select Switches Remote phone must be unplugged or remote handset If remote phone is off hook more than 10 sec panel tone re sounds and LED flashes TO RESET THE SYSTEM When the alarm condition has been cleared restore or all affected devices in accordance with the provided with each device smoke detector sensor etc Reset the system FIRE ALARM Condition Press the SYSTEM RESET PRIORITY 2 ALARM Condition Open the Operator Panel access door and press the PRIORITY ALARM RESET key on the programmable CON Key Panel The CONTROL Key Panel is located the far left of the Operator Interface Panel a short delay the system will return to normal and dis the following message IS NORMAL 27 SEP 97 SELECT SELECT SELECT SELECT SELECT SWITCH OPERATION ON EVAC ON TALK ALERT OFF AUTO YOUR SYSTEM SWITCH CONFIGURATION DOES NOT MATCH THIS SHEET CONSULT SIMPLEX SPECIFIC OPERATIONS SIMPLEX IS LISTED IN THE YELLOW PAGES CASE OF TROUBLE NOTIFY INSTRUCTIONS ARE INTENDED TO BE FRAMED AND ADJACENT TO THE CONTROL PANEL FOR READY REFERENCE Operator Instruction Manual for detailed operation NO Manuals Online 19