Simplex 4100 v8[1] 01 Front Panel Operation Instructions Addendum
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4100-v8-1-01-front-panel-operation-instructions-addendum-8317469502.pdf |
---|---|
Type | |
Size | 792.71 KB |
Downloads |
Text Preview
4100 Fire Alarm Panel Operation Instructions 8.01 Addendum A Manuals Online Trademarks 1996 Simplex Time Recorder Co All rights reserved Printed the United States of America in this document is subject to change without notice No part of this may be reproduced or transmitted in any form or by any means or mechanical for any purpose without the express written consent of Time Recorder Company and the Windows cid 228 logo are trademarks of the Microsoft Corporation Scanner cid 228 the VESDA cid 226 logo and VESDA cid 226 E70 D are registered trademarks Vision Systems are trademarks and the name and MiniVESDA cid 228 II Communication Net is protected by U S Patent No 4,796,025 Analog Detection is protected by U S Patent No 5,155,468 Detector Base is protected by U S Patent No 5,173,683 Manuals Online of Contents 1 Intelligent Interface 2 Card Statuses 2 Device Banner and Primary Status 3 Lists 3 VESDA Front Panel displays 4 Air Flow Status 4 Head Status 5 Chamber Voltage 5 Sensitivity 5 Threshold Level 5 Logs 5 Port 6 Status Types 6 Enable 6 Reset 6 to 20mA Monitor ZAM 7 Device and Point Types for 4 to 20mA Monitor ZAM 7 Panel Display 8 Front Panel Displays for AMZ 8 Screens for the 20mA Monitor ZAM 9 Logs 10 of Date Recording 11 Thresholds 12 Keys 12 Digital Alarm Communicator Transmitter SDACT 13 Fault 13 Failure 13 Documents 14 Manuals Online document has been created as an addendum to the 4100 4100 Fire Alarm Instructions document number FA4 31 201 to document the display specific to VESDA Intelligent Interface Serial Digital Alarm communicator Transmitter SDACT Monitor ZAM actual operating instructions for the front panel can be found in the mentioned document Manuals Online Intelligent Interface VESDA Early Smoke Detection System consists of hardware and software VESDA detectors communicates with the 4120 4100 4020 via the VESDA Interface Unit which provides gateway functionality between a Fire Control Panel FACP and VESDA detectors detectors are mapped into the 4100 system using a TrueAlarm format VESDA air sampling aspirating smoke detection system intelligently with the main fire alarm system to indicate the following functions Device address Alarm and pre alarm threshold levels reached total of three Sensitivity and threshold status Air sampling aspirating fan trouble not running Airflow trouble obstruction or break Smoke detector out of or at limits of calibration Light source trouble number of programmed TrueAlarm devices varies for each VESDA device as shown in the following table Devices of Devices 50 E70 D Scanner Card Statuses VESDA card statuses that are available for display at the 4120 4100 or are listed below Card Missing Failed Wrong Card VESDA Communications Failure Consumes four 4 addresses Manuals Online Intelligent Interface Device Banner and Status is the text associated with the new VESDA Point Banner and Primary display Banner Point Banner for a VESDA device is based off its point type The banner no distinction as to the VESDA device type Two new point types have added to support the VESDA devices They are cid 222 DETECTOR cid 222 MONITOR Status Primary Status of a VESDA device is derived from the generic device type point type and the logical state of the point S3SMOKE has a status of FIRE and S3UTIL has a primary status ON OFF Behavior alarm detect bit for VESDA devices is only set when the third fire threshold crossed This implies that the area being protected is not evacuated by default the alert and action thresholds are crossed devices are placed on the appropriate active list whenever an abnormal occurs If the device is configured with point type S3SMOKE a fire is indicated at the front panel and any remote annunciators configured annunciate the VESDA device This condition is resounded for each level crossed should be noted that VSCAN devices share some detector trouble statuses If of these trouble statuses is asserted four troubles will be annunciated in the one for each corresponding TrueAlarm device Lists Manuals Online Intelligent Interface VESDA Front Panel a VESDA device crossed its action threshold A LED will light and a beeping will be emitted See the 4100 4100 Fire Alarm Operating Instructions details on what action needs to be performed The Primary Status screens on front panel might be displayed as shown below DEVICE CUSTOM LABEL GOES HERE DETECTOR DEVICE CUSTOM LABEL GOES HERE DETECTOR DEVICE CUSTOM LABEL GOES HERE DETECTOR ALARM DEVICE CUSTOM LABEL GOES HERE MONITOR 1 DEVICE CUSTOM LABEL GOES HERE MONITOR 2 DEVICE CUSTOM LABEL GOES HERE MONITOR 3 Air Flow Status Detector Air Flow Status informs you that there is a problem with the air within a VESDA unit The condition could indicate one of the following trouble obstruction break will need to investigate the cause of the air flow problem It should be that if the VESDA Scanne is equipped with four monitoring units this will always be the same for the four TrueAlarm devices associated with unit i e four troubles will be reported DEVICE CUSTOM LABEL GOES HERE FLOW STATUS Manuals Online Intelligent Interface Head Status Chamber Voltage Sensitivity with the air flow status the Detector Head Status is a generic grouping of abnormalities that can occur to a VESDA detector head It should be that if the VESDA Scanne is equipped with four monitoring units this will always be the same for the four TrueAlarm devi