Simplex 4100ES, 4190, 4010ES and 4010 Network Interface Reference Network Communications, Options and Specifications Reference (A) (B) (C)

File Preview
File Preview
Click below to download for free

Text Preview

Alarm Network Reference Communications and Specifications Optics Fire Alarm Network communications available for wired or fiber optic connections Wired communications are available on Network modules available with either wired only or as a modular design allowing of either wired or fiber optic media modules Fiber optic communications are available with fiber modules on the Network interface modules or using the higher performance multiple signal optic modems Fiber optic links are point to point continuous connections between Fire Alarm nodes LED status indicators assist with system setup and communication signal modems use optical transmitters to provide transmission distances compared to copper over 20 miles 32 km may be possible with single mode fiber Designs are optimized for fiber type models are for single mode fiber or multi mode fiber Multiple signal modems are two slot modules and are with separate enclosures if required for Network node control panels modular interface modules provide Class B or Class X communications using wired or fiber optics selectable separately to match requirements media module details Provides isolated earth detection Compatible with Simplex isolated loop and protectors Electrical characteristics are similar to RS 485 signal fiber optic media module Fiber optic links provide immunity to electrical short circuits and ground conditions LED based fiber optic media module uses two fibers to communicate has type ST compatible with 62.5 125 or 50 125 fiber Bi Directional Couplers are available to allow use of fiber cable for Network communications communications fiber optic modules Laser based half duplex communications over single connections Available for single mode or multi mode fiber Refer to information summary on pages 2 and 3 and to sheet S4100 0049 for additional feature Alarm Network Communications Wired or Fiber Optic Continued Bridge Modules connect multiple loops and provide Star topology Physical Bridge Modules connect to Network using wired or fiber optic media and using modem media modules refer to sheet S4100 0057 for details TCP IP Physical Bridge Modules are similar but LAN Local Area Network compatible refer to data sheet S4100 0029 for Panel List nodes include the following Simplex fire products 4100ES 4100U 4010ES and 4010 Series Fire Alarm Panels and 4100ES or 4100U Network Display NDU 4190 Series TrueSite Workstations TSW 4190 Series Network System Integrators Legacy 4120 Series panels NPU and 2500 NDU 4190 IMS and GCC systems 4020 4002 Series and retrofitted 4100 4100 and 2120 systems NOTE Refer to individual product data sheets for specific product listing details see data sheet list on page 3 2 2013 Network Communications Module Selection Reference Interface Modules for Fire Alarm Control Panels and TrueSite Workstation Network Interface for Master Controller Network Interface for Redundant Master Controller Media Module Optic Media Module Interface with fixed wired media PCI slot card Network Interface PCI slot card Media Module Optic Media Module Interface with fixed wired media Network Interface Network Interface Media Module Optic Media Module two media modules below on 4100 6078 or 4100 6061 Interface also used with System Integrator two media modules below on 4190 6061 Network two media modules below on 4010 9817 or 4010 9922 Interface Multiple Signal Modems Reference refer to data sheet S4100 0049 for additional information Type Mode Mode Mode Fiber Modem Assembly Fire Alarm Network Example with Multiple Communication Media Fiber Modem Assembly for Expansion Mounting Fiber Modem Assembly direct mounting onto a 4100ES 4100U bay Fiber Modems are required to ordered in pairs Left Port Fiber Modems only to Right Port Fiber Modems if required one maximum to ST Coupler others or 50 125 Multi mode graded single fiber optic cable requires coupler at each end 1 CARD communications Network audio can be the same fiber modems single fiber signal modems are modules and fit in bay or in separate if required fiber optic media require dual fiber twisted shielded pair twisted pair requires overall shield N CARD 5 CARD Protection is required when leaves or enters a building 2 CARD 3 CARD twisted pair dry facility owned 4 CARD cards are single slot and fit in 4100ES 4100U CPU bay 2 2013 Multiple Signal Fiber Modems Network communications or local Control Panel communications Multiple signal fiber communicate a variety of system signal to a single fiber optic cable These modules dual slot module sized and can be housed in external for connection to smaller control panels Please to data sheet S4100 0049 for details is a summary of the distance specifications for the Signal Fiber Modems Multiple Signal Fiber Optic Modem Distance Specifications see page 4 for additional module reference Fiber Connector Fiber Connections Note backbone components must meet or exceed standard EIA TIA 568 B Industries Alliance Telecommunications Industry Association for power losses single mode fiber is preferred attenuation should be at 1310 nm Nominal 9 125 50 125 or 62.5 125 graded index ST 3 external connections maximum per link does not include connectors modems and Receive Modems Transmit 1310 nm Receive 1550 nm Modems Transmit 1550 nm Receive 1310 nm total attenuation 15 dB 1 low loss fiber fiber with attenuation of 0.34 db km a target distance of 35,000 ft km connector loss totaling 6 dB attenuation calculate the safety km x 0.34 db km 3.68 dB fiber loss dB 3.68 dB 6 dB 5 dB safety margin 2 higher loss fiber fiber with attenuation of 0.6 db km a target distance of 25,000 ft km and connector loss totaling 5 dB attenuation calculate the safety km x 0.6 db km 4.62 dB fiber loss dB 4.62 dB 5 dB 5 dB safety margin ft 1.6 km maximum distance total attenuation 6 dB or 62.5 GRIN graded index fiber Distances for Single Mode Fiber fiber type Modules 4190 6072 and 4190 9023 These examples provide a safety margin of dB or greater a 3 dB safety margin is generally Distances for Multi Mode Fiber 4100 6074 4100 6075 and 4190 9026 Additional Network Product Reference Overview with Applications Reference Signal Fiber Optic Modems and Accessories 4100ES Reference Network Display Unit NDU Workstations Fire Alarm Control Panel Fire Alarm Control Panel International Fire Alarm Control Panel Systems Integrator Bridge Reference Physical Bridge Modules Sheet

Related Files