Simplex 4100ES Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4100es-automatic-extinguishing-deluge-and-preaction-sprinkler-system-releasing-control-6297851034.pdf |
---|---|
Type | |
Size | 1.04 MB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Control Panels Automatic Extinguishing Deluge and Preaction System Releasing Control alarm is activated control using the Simplex 4100ES 4100U Fire Alarm Control Panel to provide Coverage for multiple areas of Automatic Extinguishing and or Deluge and Preaction Sprinkler System including audible escalation of events Control of compatible Listed Approved valves and Releasing appliance circuits RACs by connecting appliance circuits NACs to Suppression Peripherals for actuator supervision and control Escalation of Events Temporal or 20 bpm March Time pattern for first 120 bpm March Time pattern to indicate releasing timer On steady to indicate releasing timer expired and NOTE Requires NACs dedicated to conventional horn not SmartSync operation with strobes on separate NACs Suppression Release Peripheral with Dual Command Control Dual command control requires that both IDNet commands and an activated NAC are to initiate the desired release NAC provides wiring supervision to the actuator monitoring of coil continuity and short circuit to the coil supervision module Release Peripheral control features An on board DC DC regulator compensates for drops to the peripheral and ensures proper circuit voltage over a wide operating range Provides a single RAC for control of actuators for up 2 A using a 3 A NAC input 1 A using a 2 A NAC system components 4100ES Series control panel with Releasing Appliqu Dedicated NAC output from 4100ES or compatible Extender Coil supervision module one per RAC Maintenance Switch one per RAC Abort Switch connected via an addressable interface combined with Suppression Release Peripherals 4100ES series fire alarm control panel provides supervision and control for use in automatic and deluge or preaction releasing systems area initiating and notification devices are using either conventional or addressable per standard 4100ES capabilities The necessary system logic is implemented within the 4100ES panel as required for the local application supervisory S U P E R V IS ION MODU L E 2 A MP 2 0 8 1 9 0 4 6 E L T A L L A T ION IN S T RUC T ION S 5 7 4 4 3 7 R E V INT A IN 1 4 S E P A RA T ION E T W E E N P OW E R L IMIT E D RE D B L K A ND NON P OW E R IMIT E D Y E L B L K W IR ING A T E CODE 1 9 9 5 8 L K D NA C N A C L K IM P L E X T IM E R E C O R D E R C O G A R D N E R M A U S A circuit Switch indicator lamp SUPPRESSION DISABLE Peripheral addressable devices SUPPRESSION ABORT AND HOLD IDNET IN IN for lamp required circuit RELEASE PANEL This Control Unit has been arranged for releasing Disable all releasing device circuits prior to servicing Control Panel with Release Appliqu Series Releasing Control Typical Block Diagram listings UL 864 Control Units System UOJZ Control Unit System Fire Alarm UOXX Control Releasing Device Service SYZV Smoke System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UL 2017 Emergency Alarm System Control Units CO FSZI Process Equipment Management This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listings 7165 0026 251 7300 0026 313 SRP for allowable values and or conditions concerning material in this document Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder Co the property of Tyco Safety Products Westminster Release Control operation described in this document is also available with 4100U Control with software revision 11.05 or higher Refer to data sheet S4100 0031 for model control panel details including IDNet communications information 7 2018 listings Continued ULC S527 Control Units System Fire Alarm Control Unit Accessories System Fire UOXXC Control Units Releasing Device SYZVC Smoke Control System Equipment ULC S559 Central Station Fire Alarm System Units CSA 6.19 Gas Alarms and Accessories CZHFC ULC ORD C1076 Proprietary Burglar Alarm System ULC ORD C100 Smoke Control System Equipment APOUC UL2572 Mass Notification Systems Extinguishing Release Systems systems automatically activate electrically actuators for the release of a fire extinguishing such as dry chemical water spray foam CO2 or agent in response to fire detection device inputs as by programming of the host fire alarm control Extinguishing Release System Panels required to have a minimum of 24 hours of standby Initiating devices must be Listed Approved for the and may be wired either Class A or B actuators must be electrically compatible with the panel circuits and power supplies and are wired B to provide coil supervision or Preaction Sprinkler Systems systems automatically activate water control in response to fire detection device inputs Sprinkler Systems employ open sprinkler and provide water flow when the fire detection activates a common automatic water control They are used to deliver water simultaneously all of the system sprinkler heads This type of is applicable where the immediate application of quantities of water over large areas is the proper fire Sprinkler Systems are similar to deluge except that normally closed sprinkler heads are and supervisory air pressure is maintained in the Operation requires both an activated sprinkler head an activated fire alarm initiating device with specific determined at the host fire alarm control System Requirements Releasing actuators are controlled from a Release Peripheral 4090 9005 or Connections are 2 wire Class B releasing with only one 24 VDC actuator per circuit applicable two 12 VDC actuators in series or 12 VDC actuator per circuit may be used refer to actuator manufacturer installation documentation additional details and requirements System Requirements Continued Coil Supervision Module 2081 9046 must be wired before the actuator and located in the wiring junction box The connected RAC continuity supervision of the actuator coil wiring and provides short circuit supervision to coil supervision module Cross zoning or other alarm initiation logic per requirements is to be implemented by at the fire alarm control panel UL Listed Automatic Extinguishing Releasing requires that battery standby must be a of 24 hours with 5 minutes of alarm and that actuators are used FM Approved Automatic Extinguishing Release secondary standby to be a minimum of hours with 5 minutes of alarm Actuators must be compatible FM Approved Deluge and Preaction Sprinkler requires that initiating device circuits be A and wired to listed approved devices standby capacity must be a minimum of 90 hours with minutes of alarm and that compatible Automatic Control Valves must be used Refer to actuator on page 7 Maintenance Switches one per RAC are required NFPA 72 Their use may not be allowed in some always confirm local requirements used Simplex Maintenance Switches are to ensure that operation initiates a condition Abort Switches are available when abort operation is Connect to an addressable Supervised IAM 4090 9001 or similar addressable adapter Addressable Manual Releasing St