Simplex 4100ES Cabinet Reference Boxes, Doors, Retainers, Rack Mounting, and Accessories; S4100-0037

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Control Panels Reference Boxes Doors Dress Panels Rack Mounting and Accessories ULC CSFM Listed FM Approved NYC Acceptance 4100ES Box and door options Boxes are available sized for one two or three equipment bays each a battery bay located at the bottom Colors include platinum or red Doors are glass front with modular dress panels or solid Models are available with box and door combined for single package or packaged separately Enclosures are NEMA 1 rated wall mount enclosures are also IP30 Refer to individual 4100ES data sheets for product application listings Enclosure selection chart and dress panel selection is coordinated with cabinet Glass doors with modular dress panels provide visibility of and interface modules for fire alarm control units FACU display units NDU and remote annunciators Solid doors are for MINIPLEX Transponders and utility function where module visibility is not required enclosure details Latching dress panels easily lift off for internal access Smooth box surfaces for locally cutting conduit entrance holes exactly required Alignment markers at the top and bottom of each box side for 6 in mm or 4 in 102 mm wall studs Knockout screw nail holes are supplied for semi flush mounting cabinet rack packaging reference See Table 3 for cabinet rack listing 1 4100ES One bay cabinet 2 4100ES Two bay cabinets 3 4100ES Three bay cabinets For 4100ES one two and three bay cabinets with associated equipment Products are listed by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Code See CSFM Listing 7165 0026 251 for allowable values and or conditions concerning material presented in this document Accepted for use City of New York Department of Buildings Additional listings may be applicable contact your local Simplex product supplier for the latest status Rev 17 5 2021 Reference Boxes Doors Dress Panels Rack Mounting and Accessories selection chart See Wall mounted enclosure installation reference and for dimensions keys ship with system master controller with Glass and Dress with Solid Door and Panel Door 1 Combined box and door selection select if box and door are to be shipped together 1 Bay 2 Bay 3 Bay 1 Bay 2 Bay 3 Bay 2 Separate box and door selection select if boxes and doors are required to be shipped separately 1 Bay Platinum 2 Bay 3 Bay 1 Bay 2 Bay 3 Bay 2 3 Cabinet rack mounting controller rack mount kit one required for each master controller bay rack mounting kit one required for each expansion bay distribution module PDM rack mount kit order PDM separately per system voltage one required for cabinet rack 4 Power distribution modules VAC VAC Distribution Module PDM select each system voltage one required for 4100ES box or cabinet rack 5 Miscellaneous accessories key one is shipped with system Master Controller order for replacement or when extra keys needed B key French Appliqu Kit for 1 2 or 3 bay sizes Appliqu Retrofit Kit for 1 2 or 3 bay sizes use to identify 4100ES features when door is not used included with Master Controller Upgrade kits as detailed on data sheet Purpose Appliqu Kit Simplex Elevator Recall Control and Supervisory Control Unit Purpose Appliqu Kit Simplex Sprinkler Waterflow and Supervisory Station 4100ES One kit is supplied for each cabinet and Address Label Kit for module this if required for additional field module using knockout provided in solid door LED Power on Indicator Kit required for listing of MINIPLEX transponder semi flush box trim semi flush box trim 6 Battery reference 7 in 37 mm wide four corners and trim for top bottom and sides Notes lead acid batteries 12 VDC each two required for each battery Battery selection is required if batteries are internal Select size for each battery set Refer to data sheet S2081 0006 for details Ah Ah Ah Ah Ah Ah Ah Rev 17 5 2021 Reference Boxes Doors Dress Panels Rack Mounting and Accessories 7 Battery Accessories Shelf required for 50 Ah batteries Distribution Terminal Block mounts to side of box required for all close nippled unless cabinet receives all power from power supplies and batteries located in the cabinet 3 Rev 17 5 2021 Reference Boxes Doors Dress Panels Rack Mounting and Accessories mounted enclosure installation reference 4 Installation reference Figure 4 shows side view dimensions with minimal cabinet and door protrusion from the exterior wall For 6 in stud construction with minimum shown the door opens 90 degrees To allow the door to open 180 degrees the exposed cabinet dimension from the exterior wall must be minimum of 3 in 76 mm for both 4 in and 6 in stud construction A system ground must be provided for Earth Detection and transient protection devices This connection shall be made to an approved dedicated connection for each NFPA 70 Article 250 and NFPA 780 For additional installation information refer to Installation Instructions 579 117 4 Rev 17 5 2021 Reference Boxes Doors Dress Panels Rack Mounting and Accessories 8 Data sheet reference data sheet reference I O Modules for 4100ES 4010ES 4007ES Basic Panels with SPS Power Supplies Emergency Voice Alarm Equipment Transponders with SPS Power Supplies with SPS Power Supplies for 4120 Network Remote Annunciator Panels Command Center with SPS Power Supplies with SPS Power Supplies for ES Net Basic Panels with EPS Power Supplies Command Center with EPS Power Supplies with EPS Power Supplies for 4120 Network Transponders with EPS Power Supplies with EPS Power Supplies for ES Net Sheet 5 Rev 17 5 2021 Reference Boxes Doors Dress Panels Rack Mounting and Accessories 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 17 5 2021

Related Files