Simplex 4100ES Dual Port RS-232 Module with Master Clock Interface, Model 4100-9816

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Control Panels Dual Port RS 232 Module with Master Clock Interface ULC CSFM Listed FM MEA NYC description Dual RS 232 port module with port B dedicated for master clock time interface RS 232 port A is available for connection to printers terminals or compatible peripherals Allows the 4100ES Fire Control Panel system time to be synchronized the building master time or other desired compatible time Compatible with 4100U fire alarm control panels Includes a 4.5 ft 1.4 m connection cable with DB 25 RS 232 clock interface compatibility Connects to master time control centers such as the model 6500 that Simplex BCD binary coded decimal time signals to the model BCD Code Converter For extended timekeeping accuracy the model 6500 Time Control can be connected to GPS Time Reference Interface Module Compatible with other RS 232 interfaces that accept and respond to query time and QD query date requests Motherboard daughter card format requires a single slot and mounts an expansion bay fire alarm control units maintain time and date for reference in history logs For applications where a master time control exists in facility the 4100 9816 Master Clock Interface Module provides an for coordinating the fire alarm control panel time to that of the reference time accuracy requirements include synchronization to GPS time the GPS 6400 Interface Module with the GPS 427A can be connected to the model 6400 or 6351 Time Center additional information refer to Installation and Operating 574 913 additional BCD Code Converter information refer to datasheet For additional 6500 information refer to data sheet For additional GPS 6400 information refer to data sheet 1 4100ES Master Clock Interface Block Diagram Interface System Series Time Control Center with system clocks Code Converter Fire Alarm Control Panel Master Clock Interface Module This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 0026 251 for allowable and or conditions concerning material presented in this document It is subject to re examination revision and possible cancellation Additional listings may be applicable contact your local product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Safety Products Westminster Rev 5 3 2021 Dual Port RS 232 Module with Master Clock Interface Current Current Temperature Range Range Provided 1 Specifications mA 24 VDC mA 24 VDC to 120 0 to 49 to 93 RH non condensing 90 32 slot motherboard daughter card plugs and terminal blocks Master Clock Interface System Reference 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 5 3 2021

Related Files